110 research outputs found

    The shielding effect of phospholipidic bilayers on zinc oxide nanocrystals for biomedical applications

    Get PDF
    Zinc oxide nanocrystals (ZnO NCs), thanks to their unique properties, are receiving much attention for their use in nanomedicine, in particular for therapy against cancer [1]. To be efficiently employed as diagnostic and therapeutic (yet theranostic) tools [2], highly dispersed, stable and non-toxic nanoparticles are required. In the case of ZnO NCs, there is still a lack of knowledge about cytotoxicity mechanisms and stability in the biological context, as well as immunological response and haemocompatible features. Most of these above-mentioned behaviours strongly depends on physico-chemical and surface properties of the nanoparticles. We thus propose a novel approach to stabilize the ZnO NCs in various biological media, focusing on NC aggregation and biodegradation as a function of the surface functionalization. We synthesized bare ZnO NCs, amino-propyl functionalized ones, and lipid bilayer-shielded NCs, and we characterized their morphological, chemical and physical properties. The stability behavior of the three different samples was evaluated, comparing their biodegradation profiles in different media, i.e. organic solvents, water, and different simulated and biological fluids. The studies aim to investigate how the particle surface functionalizations, and thus chemistry and charge, could influence their hydrodynamic size, zeta potential and consequent aggregation and degradation in the different solvents. We demonstrated that bare and amino-functionalized ZnO NCs strongly and rapidly aggregate when suspended in both simulated and biological media. Long-term biodegradation analysis showed small dissolution into potentially cytotoxic Zn-cations, also slightly affecting their crystalline structure. In contrast, high colloidal stability and integrity was retained for lipid-shielded ZnO NCs in all media, rendering them the ideal candidates for further theranostic applications [3]. [1] P. Zhu, Z. Weng, X. Li, X. Liu, S. Wu Adv. Mater. Interfaces 3 (2016) 1500494. [2] E. Lim, T. Kim, S. Paik, S. Haam, Y. Huh, and K. Lee, Chem. Rev. 115 (2015) 327−394. [3] B. Dumontel, M. Canta, H. Engelke, A. Chiodoni, L. Racca, A. Ancona, T. Limongi, G. Canavese and V. Cauda, J. Mater. Chem. B, under review The support from ERC Starting Grant – Project N. 678151 “Trojananohorse” and Compagnia di Sanpaolo are gratefully acknowledged

    Biomimetic Non-Immunogenic Nanoassembly for the Antitumor Therapy

    Get PDF
    Nanoassembly (1) for inducing apoptosis in cancer cells comprising: a core (2) comprising at least a nanoparticle of a nano structured and semiconductor metal oxide, said nanoparticle being monocrystalline or polycrystalline; a shell (3) formed by a double phospholipid layer and proteins derived from an extracellular biovesicole chosen between an exosome, an ectosome, a connectosome, an oncosome and an apoptotic body, and an oncosome, said core (2) being enclosed inside said shell (3); and a plurality of targeting molecules (4, 4', 4") of said cancer cells, preferably monoclonal antibodies (4, 4', 4"), said molecules (4, 4', 4") being anchored to the external surface of said biovesicole

    Enhanced Biostability and Cellular Uptake of Zinc Oxide Nanocrystals Shielded with Phospholipid Bilayer

    Get PDF
    The widespread use of ZnO nanomaterials for biomedical applications, including therapeutic drug delivery or stimuli-responsive activation, as well as imaging, imposes a careful control over the colloidal stability and long-term behaviour of ZnO in biological media. Moreover, the effect of ZnO nanostructures on living cells, in particular cancer cells, is still under debate. This paper discusses the role of surface chemistry and charge of zinc oxide nanocrystals, of around 15 nm in size, which influence their behaviour in biological fluids and effect on cancer cells. In particular, we address this problem by modifying the surface of pristine ZnO nanocrystals (NCs), rich of hydroxyl groups, with positively charged amino-propyl chains or, more innovatively, by self-assembling a double-lipidic membrane, shielding the ZnO NCs. Our findings show that the prolonged immersion in simulated human plasma and in the cell culture medium leads to highly colloidally dispersed ZnO NCs only when coated by the lipidic bilayer. In contrast, the pristine and amine-functionalized NCs form huge aggregates after already one hour of immersion. Partial dissolution of these two samples into potentially cytotoxic Zn2+ cations takes place, together with the precipitation of phosphate and carbonate salts on the NCs’ surface. When exposed to living HeLa cancer cells, higher amounts of lipid-shielded ZnO NCs are internalized with respect to the other samples, thus showing a reduced cytotoxicity, based on the same amount of internalized NCs. These results pave the way for the development of novel theranostic platforms based on ZnO NCs. The new formulation of ZnO shielded with a lipid-bilayer will prevent strong aggregation and premature degradation into toxic by-products, and promote a highly efficient cell uptake for further therapeutic or diagnostic functions

    Neurofilament light chain: a specific serum biomarker of axonal damage severity in rat models of Chemotherapy-Induced Peripheral Neurotoxicity

    Get PDF
    Chemotherapy-Induced Peripheral Neurotoxicity (CIPN) is a severe and long-lasting side effect of anticancer therapy, which can severely impair patients’ quality of life. It is a sensory and length-dependent neuropathy, which predominantly affects large myelinated fibers. Easy and reliable monitoring of CIPN in patients is still an unmet clinical need. Since increasing clinical evidence supports the potential use of neurofilament light chain (NfL) as a biomarker of axonal injury, in this study we measured serum NfL levels in animals chronically treated with cisplatin (CDDP) and paclitaxel (PTX), two antineoplastic drugs with different neuronal targets. Wistar rats were treated with CDDP (2 mg/kg i.p. twice/week for 4 weeks) or PTX (10 mg/kg i.v. once/week for 4 weeks). Repeated serum NfL quantification was obtained using the Single Molecule Array (Simoa) technology. The onset and progression of peripheral neurotoxicity were evaluated through neurophysiology, morphological assessments and intraepidermal nerve fibers density quantification. Our results showed that serum NfL measurements correlated with the severity of axonal damage. In fact, both treatments induced serum NfL increase, but higher levels were evidenced in PTX-treated animals, compared with CDDP-treated rats, affected by a milder neurotoxicity. Notably, also the timing of the NfL level increase was associated with the severity of morphological and functional alterations of axonal structure. Therefore, NfL could be a useful biomarker for axonal damage in order to follow the onset and severity of axonal degeneration and possibly limit the occurrence of serious PNS disease

    Assessment of Patient Satisfaction Using a New Augmented Reality Simulation Software for Breast Augmentation: A Prospective Study

    Get PDF
    Background: Breast augmentation is one of the most frequently performed plastic surgery procedures. Providing patients with realistic 3D simulations of breast augmentation outcomes is becoming increasingly common. Until recently, such programs were expensive and required significant equipment, training, and office space. New simple user-friendly programs have been developed, but to date there remains a paucity of objective evidence comparing these 3D simulations with post-operative outcomes. The aim of this study is to assess the aesthetic similarity between a preoperative 3D simulation generated using Arbrea breast simulation software and real post-operative outcomes, with a focus on patient satisfaction. Methods: The authors conducted a prospective study of patients requiring breast augmentation. Patients were asked to assess how realistic the simulation was compared to the one-year post-operative result using the authors’ grading scale for breast augmentation simulation assessment. Patient satisfaction with the simulations was assessed using a satisfaction visual analogue scale (VAS) ranging from 0 (not at all satisfied) to 10 (very satisfied). Patient satisfaction with the surgical outcome was assessed using the BREAST-Q Augmentation Module. Results: All patients were satisfied with the simulations and with the attained breast volume, with a mean VAS score of 8.2   1.2. The mean simulation time took 90 s on average. The differences between the pre-operative and one-year post-operative values of the three BREAST-Q assessments were found to be statistically significant (p < 0.001). Conclusions: Three-dimensional simulation is becoming increasingly common in pre-operative planning for breast augmentation. The present study aimed to assess the degree of similarity of three-dimensional simulations generated using Arbrea Breast Software and found that the use of the software provided a very satisfying representation for patients undergoing breast augmentation. However, we recommend informing patients that only the volume simulation is extremely accurate. On the other hand, it is necessary to not guarantee an absolute correspondence regarding the breast shape between the simulation and the post-operative result

    Islet transplantation and insulin administration relieve long-term complications and rescue the residual endogenous pancreatic cells

    Get PDF
    Islet transplantation is a poorly investigated Long-term strategy for insulin replacement and for treatment of complications in patients with diabetes. We investigated whether islet transplantation and insulin treatment can relieve diabetic neuropathy and rescue the residual endogenous pancreatic beta cells. We used a multimodal approach, with five groups of Sprague-Dawley rats studied for 8 months: control rats, diabetic rats, insulin-treated diabetic rats with moderate or mild hyperglycemia, and diabetic rats transplanted with microencapsulated islets. Islet transplantation normalized glycemia and increased body and muscle weight; it was also effective in reducing proteinuria and altered liver function. Transplantation significantly improved tail nerve conduction velocity, Na+-K+-ATPase activity, and morphological alterations in the sciatic nerve as evidenced by decrease in g-ratio; it also restored thermal and ameliorated mechanical nociceptive thresholds. Morphometric analysis of pancreas indicated a significant beta-cell volume increase in transplanted rats, compared with mildly and moderately hyperglycemic rats. Thus, allogeneic islet transplantation had a positive systemic effect in diabetic rats and induced regression of the established neuropathy and restitution of the typical characteristics of the islets. These findings strongly reinforce the need for improving glycemic control, not only to reverse established diabetic complications but also to improve beta-cell status in diabetic pancreas

    Clinical autonomic nervous system laboratories in Europe. A joint survey of the European Academy of Neurology and the European Federation of Autonomic Societies

    Get PDF
    Background and purpose: Disorders of the autonomic nervous system (ANS) are common conditions, but it is unclear whether access to ANS healthcare provision is homogeneous across European countries. The aim of this study was to identify neurology-driven or interdisciplinary clinical ANS laboratories in Europe, describe their characteristics and explore regional differences. Methods: We contacted the European national ANS and neurological societies, as well as members of our professional network, to identify clinical ANS laboratories in each country and invite them to answer a web-based survey. Results: We identified 84 laboratories in 22 countries and 46 (55%) answered the survey. All laboratories perform cardiovascular autonomic function tests, and 83% also perform sweat tests. Testing for catecholamines and autoantibodies are performed in 63% and 56% of laboratories, and epidermal nerve fiber density analysis in 63%. Each laboratory is staffed by a median of two consultants, one resident, one technician and one nurse. The median (interquartile range [IQR]) number of head-up tilt tests/laboratory/year is 105 (49–251). Reflex syncope and neurogenic orthostatic hypotension are the most frequently diagnosed cardiovascular ANS disorders. Thirty-five centers (76%) have an ANS outpatient clinic, with a median (IQR) of 200 (100–360) outpatient visits/year; 42 centers (91%) also offer inpatient care (median 20 [IQR 4–110] inpatient stays/year). Forty-one laboratories (89%) are involved in research activities. We observed a significant difference in the geographical distribution of ANS services among European regions: 11 out of 12 countries from North/West Europe have at least one ANS laboratory versus 11 out of 21 from South/East/Greater Europe (p = 0.021). Conclusions: This survey highlights disparities in the availability of healthcare services for people with ANS disorders across European countries, stressing the need for improved access to specialized care in South, East and Greater Europe

    Larger is Better: The Scale Effects of the Italian Local Healthcare Authorities Amalgamation Program

    Get PDF
    Consolidation is often considered as a means to lower service delivery costs and enhance accountability. This paper uses a prospective evaluation design to derive estimates of the potential cost savings that may arise from Local Healthcare Authorities (LHAs) amalgamation process, which is concerning the Itali an National Health System. We focus specifically on cost savings due to scale economies with reference to a particular subset of the production costs of the LHAs, i.e. the administrative costs together with the purchasing costs of both goods as well as non-healthcare related services. Our results demonstrate the existence of economies of scale linked to the size of the LHA population. Hence, the decision to reduce the number of LHAs may result in larger local health authorities that are more cost efficient, especially when the consolidation process concerns merging a large number of LHA

    Antimicrobial resistance among migrants in Europe: a systematic review and meta-analysis

    Get PDF
    BACKGROUND: Rates of antimicrobial resistance (AMR) are rising globally and there is concern that increased migration is contributing to the burden of antibiotic resistance in Europe. However, the effect of migration on the burden of AMR in Europe has not yet been comprehensively examined. Therefore, we did a systematic review and meta-analysis to identify and synthesise data for AMR carriage or infection in migrants to Europe to examine differences in patterns of AMR across migrant groups and in different settings. METHODS: For this systematic review and meta-analysis, we searched MEDLINE, Embase, PubMed, and Scopus with no language restrictions from Jan 1, 2000, to Jan 18, 2017, for primary data from observational studies reporting antibacterial resistance in common bacterial pathogens among migrants to 21 European Union-15 and European Economic Area countries. To be eligible for inclusion, studies had to report data on carriage or infection with laboratory-confirmed antibiotic-resistant organisms in migrant populations. We extracted data from eligible studies and assessed quality using piloted, standardised forms. We did not examine drug resistance in tuberculosis and excluded articles solely reporting on this parameter. We also excluded articles in which migrant status was determined by ethnicity, country of birth of participants' parents, or was not defined, and articles in which data were not disaggregated by migrant status. Outcomes were carriage of or infection with antibiotic-resistant organisms. We used random-effects models to calculate the pooled prevalence of each outcome. The study protocol is registered with PROSPERO, number CRD42016043681. FINDINGS: We identified 2274 articles, of which 23 observational studies reporting on antibiotic resistance in 2319 migrants were included. The pooled prevalence of any AMR carriage or AMR infection in migrants was 25·4% (95% CI 19·1-31·8; I2 =98%), including meticillin-resistant Staphylococcus aureus (7·8%, 4·8-10·7; I2 =92%) and antibiotic-resistant Gram-negative bacteria (27·2%, 17·6-36·8; I2 =94%). The pooled prevalence of any AMR carriage or infection was higher in refugees and asylum seekers (33·0%, 18·3-47·6; I2 =98%) than in other migrant groups (6·6%, 1·8-11·3; I2 =92%). The pooled prevalence of antibiotic-resistant organisms was slightly higher in high-migrant community settings (33·1%, 11·1-55·1; I2 =96%) than in migrants in hospitals (24·3%, 16·1-32·6; I2 =98%). We did not find evidence of high rates of transmission of AMR from migrant to host populations. INTERPRETATION: Migrants are exposed to conditions favouring the emergence of drug resistance during transit and in host countries in Europe. Increased antibiotic resistance among refugees and asylum seekers and in high-migrant community settings (such as refugee camps and detention facilities) highlights the need for improved living conditions, access to health care, and initiatives to facilitate detection of and appropriate high-quality treatment for antibiotic-resistant infections during transit and in host countries. Protocols for the prevention and control of infection and for antibiotic surveillance need to be integrated in all aspects of health care, which should be accessible for all migrant groups, and should target determinants of AMR before, during, and after migration. FUNDING: UK National Institute for Health Research Imperial Biomedical Research Centre, Imperial College Healthcare Charity, the Wellcome Trust, and UK National Institute for Health Research Health Protection Research Unit in Healthcare-associated Infections and Antimictobial Resistance at Imperial College London

    EFAS/EAN survey on the influence of the COVID-19 pandemic on European clinical autonomic education and research

    Get PDF
    © The Author(s) 2023. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.Purpose: To understand the influence of the coronavirus disease 2019 (COVID-19) pandemic on clinical autonomic education and research in Europe. Methods: We invited 84 European autonomic centers to complete an online survey, recorded the pre-pandemic-to-pandemic percentage of junior participants in the annual congresses of the European Federation of Autonomic Societies (EFAS) and European Academy of Neurology (EAN) and the pre-pandemic-to-pandemic number of PubMed publications on neurological disorders. Results: Forty-six centers answered the survey (55%). Twenty-nine centers were involved in clinical autonomic education and experienced pandemic-related didactic interruptions for 9 (5; 9) months. Ninety percent (n = 26/29) of autonomic educational centers reported a negative impact of the COVID-19 pandemic on education quality, and 93% (n = 27/29) established e-learning models. Both the 2020 joint EAN-EFAS virtual congress and the 2021 (virtual) and 2022 (hybrid) EFAS and EAN congresses marked higher percentages of junior participants than in 2019. Forty-one respondents (89%) were autonomic researchers, and 29 of them reported pandemic-related trial interruptions for 5 (2; 9) months. Since the pandemic begin, almost half of the respondents had less time for scientific writing. Likewise, the number of PubMed publications on autonomic topics showed the smallest increase compared with other neurological fields in 2020-2021 and the highest drop in 2022. Autonomic research centers that amended their trial protocols for telemedicine (38%, n = 16/41) maintained higher clinical caseloads during the first pandemic year. Conclusions: The COVID-19 pandemic had a substantial negative impact on European clinical autonomic education and research. At the same time, it promoted digitalization, favoring more equitable access to autonomic education and improved trial design.info:eu-repo/semantics/publishedVersio
    corecore