733 research outputs found

    Production of He-4 and (4) in Pb-Pb collisions at root(NN)-N-S=2.76 TeV at the LHC

    Get PDF
    Results on the production of He-4 and (4) nuclei in Pb-Pb collisions at root(NN)-N-S = 2.76 TeV in the rapidity range vertical bar y vertical bar <1, using the ALICE detector, are presented in this paper. The rapidity densities corresponding to 0-10% central events are found to be dN/dy4(He) = (0.8 +/- 0.4 (stat) +/- 0.3 (syst)) x 10(-6) and dN/dy4 = (1.1 +/- 0.4 (stat) +/- 0.2 (syst)) x 10(-6), respectively. This is in agreement with the statistical thermal model expectation assuming the same chemical freeze-out temperature (T-chem = 156 MeV) as for light hadrons. The measured ratio of (4)/He-4 is 1.4 +/- 0.8 (stat) +/- 0.5 (syst). (C) 2018 Published by Elsevier B.V.Peer reviewe

    Incidence and Predictors of Unplanned Hospital Readmission after Percutaneous Coronary Intervention

    No full text
    Unplanned readmissions to hospital after percutaneous coronary intervention (PCI) pose a significant burden to the healthcare system and are potentially preventable. In this study, we sought to determine the incidence of, and risk factors for, unplanned hospital readmissions within 30 days following PCI. We prospectively collected data on 28,488 patients undergoing PCI between 2013 and 2019, who were enrolled in the state-wide multi-centre Victorian Cardiac Outcomes Registry. Patients&rsquo; data were then linked to data from the Victorian Department of Health administrative database that records statewide hospital admissions. Disease diagnosis codes were used to identify cause of readmission. Patients who had an unplanned readmission were further divided into those who had a cardiac vs. non-cardiac cause for readmission. Overall, 3059 patients (10.7%) had an unplanned hospital readmission within 30 days of PCI, of which 1848 patients (60.4%) were readmitted for primarily cardiac diagnoses. Independent predictors of both 30-day unplanned cardiac and non-cardiac readmissions post-PCI were female sex, having &ge;1 admission in the 12 months prior to PCI, acute coronary syndrome presentation, having any in-hospital complication and being discharged on an oral anticoagulant (all p &lt; 0.05). A stepwise increase in readmission risk was observed with increasing number of admissions from 1 to &ge;4 admissions in the 12 months prior to PCI. In conclusion, a substantial proportion of patients undergoing PCI have unexpected readmissions to hospital in the 30 days following PCI. Targeted strategies for patients with risk factors for readmission may be useful to reduce this significant burden to the healthcare system

    Bench test and in-vivo evaluation of longitudinal stent deformation during proximal optimisation

    No full text
    While radial stent deformation has been thoroughly investigated, data on longitudinal deformation are scarce.The aim of the study was to describe longitudinal stent deformation associated with the proximal optimisation technique (POT).Longitudinal stent deformation was assessed by bench testing and by clinical evaluation. Bench testing was performed in silicone models using 3.00 (n=15) and 3.50 mm (n=14) stent platforms. After deployment, stents were sequentially post-dilated in the proximal main branch up to 5.50 mm, in increments of 0.50 mm, in order to simulate a spectrum of overexpansion. Stent length was redefined by optical coherence tomography (OCT) after each step. Clinical data were collected retrospectively from OCT-guided bifurcation PCI cases.In bench tests, POT has led to significant stent elongation in all cases. The magnitude of elongation was comparable between the 3.00 and the 3.50 mm stent platforms, with 0.86±0.74 mm vs 0.86±0.73 mm, respectively (p=0.71), per 0.5 mm overexpansion. For 3.00 mm stent platform, maximal elongation was 4.31±1.47 mm after up to 5.5 mm overexpansion. For 3.50 mm platform, maximal elongation was 2.87±0.94 mm after up to 5.5 mm overexpansion. Thirty-six clinical cases were analysed, of which 22 (61%) were performed in the distal left main. Post-dilation was performed with 0.98±0.36 mm absolute overexpansion, resulting in 2.22±1.35 mm elongation, as compared to nominal stent length.Overexpansion by POT results in proximal stent elongation. This has to be considered once the stent length is selected and the stent is positioned, especially in the left main stem, where proximal overexpansion is marked and accurate ostial landing is critical

    Markers of Cardiovascular Disease among Adults Exposed to Smoke from the Hazelwood Coal Mine Fire

    No full text
    Little research has examined the effects of high concentration, medium-duration smoke exposure on cardiovascular health. We investigated whether six weeks of exposure to smoke from the 2014 Hazelwood coal mine fire in Victoria (Australia), was associated with long-term clinical or subclinical cardiovascular disease approximately four years later, in adult residents of the towns of Morwell (exposed, n = 336) and Sale (unexposed, n = 162). The primary outcome was serum high sensitivity (hs) C-reactive protein (CRP). Blood pressure, electrocardiogram, flow mediated dilatation and serum levels of hs-troponin, N-terminal pro B-type natriuretic peptide and lipids were secondary outcomes. There was no significant difference in weighted median hsCRP levels between exposed and unexposed participants (1.9 mg/L vs. 1.6 mg/L, p = 0.273). Other outcomes were comparable between the groups. hsCRP was associated in a predictable manner with current smoking, obesity and use of lipid-lowering therapy. Four years after a 6-week coal mine fire, this study found no association between smoke exposure and markers of clinical or subclinical cardiovascular disease in exposed adults

    Does the subtype of acute coronary syndrome treated by percutaneous coronary intervention predict long-term clinical outcomes?

    No full text
    © The Author 2017. Aims The prognosis of patients undergoing percutaneous coronary intervention (PCI) for different subtypes of acute coronary syndromes (ACS) remains unclear. We compared short- and long-term mortality in patients undergoing PCI for unstable angina (UA), non-ST-elevation myocardial infarction (NSTEMI), and ST-elevation myocardial infarction (STEMI). Methods and results This was a retrospective cohort study of 13 184 patients (5966 STEMI, 5307 NSTEMI, and 1911 UA) undergoing PCI between 1 January 2005 and 30 November 2013 in a multi-centre registry. Clinical and procedural characteristics, as well as outcomes, were compared by ACS subtype. Long-term all-cause mortality data were obtained via linkage to the National Death Index (NDI). Patients with STEMI compared with NSTEMI and UA were younger (62.9 ± 12.8 vs. 64.7 ± 12.5 vs. 65.5 ± 11.8 years; P &lt; 0.01), had fewer comorbidities including diabetes, heart failure, and previous myocardial infarction (all P &lt; 0.01). Procedural success was similar across all groups (P = 0.54). In-hospital, 30-day and 1-year all-cause mortality increased significantly from UA to NSTEMI to STEMI patients (1-year mortality 2.5% vs. 4.5% vs. 8.7%; P &lt; 0.01). Kaplan-Meier survival estimates showed increased early mortality in the STEMI group (log-rank P &lt; 0.01). However, after approximately 8.2 years, survival was similar across all groups. In a proportional-odds model using flexible parametric survival modelling, ACS subtype was not an independent predictor of NDI-linked mortality [UA: odds ratio (OR) 0.85, 95% CI 0.71-1.02; STEMI: OR 1.01, 95% confidence interval (CI) 0.88-1.16; NSTEMI as reference category]. Conclusion Despite disparate baseline characteristics and differences in short-term mortality, long-term mortality was similar across the spectrum of ACS treated by PCI and contemporary medical therapy

    The everolimus eluting Synergy MegatronTM drug-eluting stent platform:Early outcomes from the European Synergy MegatronTM Implanters' Registry

    Get PDF
    Background: The Synergy Megatron TM is an everolimus-drug eluting stent that may offer advantages in the treatment of aorto-ostial disease and large proximal vessels. Aims: To report the short- to medium-term clinical outcomes from the European Synergy Megatron TM Implanters' Registry. Methods: This registry was an investigator-initiated study conducted at 14 European centers. The primary outcome was target lesion failure (TLF), defined as the composite of cardiovascular death, target vessel myocardial infarction (MI), and target lesion revascularisation. Results: Five hundred seventy-five patients underwent PCI with Megatron TM between 2019 and 2021. Patients were 69 ± 12 years old, 26% had diabetes mellitus, 24% had moderate-severe left ventricular impairment and 59% presented with an acute coronary syndrome. 15% were deemed prohibitively high risk for surgical revascularisation. The target vessel involved the left main stem in 55%, the ostium of the RCA in 13% and was a true bifurcation (Medina 1,1,1) in 50%. At 1 year, TLF was observed in 40 patients, with 26 (65%) occurring within the first 30 days. The cumulative incidence of TLF was 4.5% at 30 days and 8.6% (95% CI 6.3–11.7) at 1 year. The incidence of stent thrombosis was 0.5% with no late stent thromboses. By multivariate analysis, the strongest independent predictors of TLF were severe left ventricular impairment (HR 3.43, 95% CI: 1.67–6.76, p &lt; 0.001) and a target vessel involving the left main (HR 4.00 95% CI 1.81–10.15 p = 0.001). Conclusions: Use of the Synergy Megatron TM everolimus eluting stent in a ‘real-world’ setting shows favorable outcomes at 30 days and 1 year.</p

    Multiplicity dependence of light (anti-)nuclei production in p–Pb collisions at sNN=5.02 TeV

    Get PDF
    The measurement of the deuteron and anti-deuteron production in the rapidity range −1 < y < 0 as a function of transverse momentum and event multiplicity in p–Pb collisions at √sNN = 5.02 TeV is presented. (Anti-)deuterons are identified via their specific energy loss dE/dx and via their time-of- flight. Their production in p–Pb collisions is compared to pp and Pb–Pb collisions and is discussed within the context of thermal and coalescence models. The ratio of integrated yields of deuterons to protons (d/p) shows a significant increase as a function of the charged-particle multiplicity of the event starting from values similar to those observed in pp collisions at low multiplicities and approaching those observed in Pb–Pb collisions at high multiplicities. The mean transverse particle momenta are extracted from the deuteron spectra and the values are similar to those obtained for p and particles. Thus, deuteron spectra do not follow mass ordering. This behaviour is in contrast to the trend observed for non-composite particles in p–Pb collisions. In addition, the production of the rare 3He and 3He nuclei has been studied. The spectrum corresponding to all non-single diffractive p-Pb collisions is obtained in the rapidity window −1 < y < 0 and the pT-integrated yield dN/dy is extracted. It is found that the yields of protons, deuterons, and 3He, normalised by the spin degeneracy factor, follow an exponential decrease with mass number

    Dual endothelin antagonist aprocitentan for resistant hypertension (PRECISION): a multicentre, blinded, randomised, parallel-group, phase 3 trial

    No full text
    Auteurs : the PRECISION investigatorsInternational audienceBackground Resistant hypertension is associated with increased cardiovascular risk. The endothelin pathway has been implicated in the pathogenesis of hypertension, but it is currently not targeted therapeutically, thereby leaving this relevant pathophysiological pathway unopposed with currently available drugs. The aim of the study was to assess the blood pressure lowering efficacy of the dual endothelin antagonist aprocitentan in patients with resistant hypertension. Methods PRECISION was a multicentre, blinded, randomised, parallel-group, phase 3 study, which was done in hospitals or research centres in Europe, North America, Asia, and Australia. Patients were eligible for randomisation if their sitting systolic blood pressure was 140 mm Hg or higher despite taking standardised background therapy consisting of three antihypertensive drugs, including a diuretic. The study consisted of three sequential parts: part 1 was the 4-week double-blind, randomised, and placebo-controlled part, in which patients received aprocitentan 12•5 mg, aprocitentan 25 mg, or placebo in a 1:1:1 ratio; part 2 was a 32-week single (patient)-blind part, in which all patients received aprocitentan 25 mg; and part 3 was a 12-week double-blind, randomised, and placebo-controlled withdrawal part, in which patients were re-randomised to aprocitentan 25 mg or placebo in a 1:1 ratio. The primary and key secondary endpoints were changes in unattended office systolic blood pressure from baseline to week 4 and from withdrawal baseline to week 40, respectively. Secondary endpoints included 24-h ambulatory blood pressure changes. The study is registered on ClinicalTrials.gov, NCT03541174. Findings The PRECISION study was done from June 18, 2018, to April 25, 2022. 1965 individuals were screened and 730 were randomly assigned. Of these 730 patients, 704 (96%) completed part 1 of the study; of these, 613 (87%) completed part 2 and, of these, 577 (94%) completed part 3 of the study. The least square mean (SE) change in office systolic blood pressure at 4 weeks was-15•3 (SE 0•9) mm Hg for aprocitentan 12•5 mg,-15•2 (0•9) mm Hg for aprocitentan 25 mg, and-11•5 (0•9) mm Hg for placebo, for a difference versus placebo of-3•8 (1•3) mm Hg (97•5% CI-6•8 to-0•8, p=0•0042) and-3•7 (1•3) mm Hg (-6•7 to-0•8; p=0•0046), respectively. The respective difference for 24 h ambulatory systolic blood pressure was-4•2 mm Hg (95% CI-6•2 to-2•1) and-5•9 mm Hg (-7•9 to-3•8). After 4 weeks of withdrawal, office systolic blood pressure significantly increased with placebo versus aprocitentan (5•8 mm Hg, 95% CI 3•7 to 7•9, p<0•0001). The most frequent adverse event was mild-to-moderate oedema or fluid retention, occurring in 9%, 18%, and 2% for patients receiving aprocitentan 12•5 mg, 25 mg, and placebo, during the 4-week double-blind part, respectively. This event led to discontinuation in seven patients treated with aprocitentan. During the trial, a total of 11 treatment-emergent deaths occurred, none of which were regarded by the investigators to be related to study treatment. Interpretation In patients with resistant hypertension, aprocitentan was well tolerated and superior to placebo in lowering blood pressure at week 4 with a sustained effect at week 40

    Elliptic Flow of Electrons from Beauty-Hadron Decays in Pb-Pb Collisions at sNN\sqrt {s_{NN}} = 5.02 TeV

    No full text
    The elliptic flow of electrons from beauty hadron decays at midrapidity (|y|<0.8) is measured in Pb-Pb collisions at sNN\sqrt {s_{NN}} = 5.02 TeV with the ALICE detector at the LHC. The azimuthal distribution of the particles produced in the collisions can be parametrized with a Fourier expansion, in which the second harmonic coefficient represents the elliptic flow, v2v_2. The v2v_2 coefficient of electrons from beauty hadron decays is measured for the first time in the transverse momentum (pTp_T) range 1.3–6 GeV/c in the centrality class 30%–50%. The measurement of electrons from beauty-hadron decays exploits their larger mean proper decay length cτ ≈ 500 μm compared to that of charm hadrons and most of the other background sources. The v2v_2 of electrons from beauty hadron decays at midrapidity is found to be positive with a significance of 3.75 σ. The results provide insights into the degree of thermalization of beauty quarks in the medium. A model assuming full thermalization of beauty quarks is strongly disfavored by the measurement at high pTp_T, but is in agreement with the results at low pTp_T. Transport models including substantial interactions of beauty quarks with an expanding strongly interacting medium describe the measurement within uncertainties
    corecore