1,998 research outputs found

    Washing machine dynamic model to prevent tub collision during transient state

    Get PDF
    In horizontal-axis washing machines, the front gasket as well as the damping system are crucial owing to the possible collision of the tub with the housing during the transient period. However, most dynamic models for predicting tub motion focus on the steady state and consider only the suspension system without including the gasket. We conducted an experimental study to analyze the effect of the gasket on the transient motion of the tub. The results obtained indicate the necessity of implementing the gasket in the multibody model of a washing machine to accurately predict the tub behavior during this period. The gasket model is formed by a combination of Voigt elements. Stiffness parameters are determined using a load cell, and damping factors are estimated using a process that integrates Adams/View, Matlab optimization algorithms, and displacement measurements that are taken using accelerometers. A D-optimal design used to predict the effect of the gasket parameters reveals that the tub displacement is most sensitive to the changes in linear stiffness in the transversal direction. Finally, the model of the gasket provides a better approach for predicting the tub movement during resonance that can be used in the design phase to avoid tub collision

    Determination of regulated and emerging mycotoxins in organic and conventional gluten-free flours by LC-MS/MS

    Get PDF
    Gluten-free cereal products have grown in popularity in recent years as they are perceived as “healthier” alternatives and can be safely consumed by celiac patients, and people with gluten intolerance or wheat allergies. Molds that produce mycotoxins contaminate cereal crops, posing a threat to global food security. Maximum levels have been set for certain mycotoxins in cereal flours; however, little is known about the levels of emerging mycotoxins in these flours. The aim of this study was to develop an efficient, sensitive, and selective method for the detection of four emerging (beauvericin and enniatins A1, B, and B1) and three regulated (aflatoxin B1, zearalenone, and deoxynivalenol) mycotoxins in gluten-free flours. Ultrasound-assisted matrix solid-phase dispersion was used in the extraction of these mycotoxins from flour samples. The validated method was utilized for the LC-MS/MS analysis of conventional and organic wholegrain oat and rice flours. Six of the seven target mycotoxins were detected in these samples. Multi-mycotoxin contamination was found in all flour types, particularly in conventional wholegrain oat flour. Despite the low detection frequency in rice flour, one sample was found to contain zearalenone at a concentration of 83.2 ”g/kg, which was higher than the level set by the European Commission for cereal flours. The emerging mycotoxins had the highest detection frequencies; enniatin B was present in 53% of the samples at a maximum concentration of 56 ”g/kg, followed by enniatin B1 and beauvericin, which were detected in 46% of the samples, and at levels reaching 21 ”g/kg and 10 ”g/kg, respectively. These results highlight the need to improve the current knowledge and regulations on the presence of mycotoxins, particularly emerging ones, in gluten-free flours and cereal-based product

    Matrixes of unconventional micro-optical components molded with etched silicon

    Get PDF
    This paper reports on a process to create microlenses characterized by unconventional footprints, spherical profiles and a wide range of sizes. Fabricated shapes such as squares, rectangles, ellipses, triangles and hexagons are tested alone as well as in matrix with high fulfill factors. The technique is based on molds from which microlenses are fabricated by UV-molding replication. The molds are produced by silicon wet isotropic etching in an acid solution. The process is mainly steered by temperature and etching concentration. The use of the proposed technology opens a wide range of geometries allowing the fabrication of microlenses matrices with high fulfill factors as well as microlenses for beam-shaping

    Methodological approaches to determining the marine radiocarbon reservoir effect

    Get PDF
    The marine radiocarbon reservoir effect is an offset in 14C age between contemporaneous organisms from the terrestrial environment and organisms that derive their carbon from the marine environment. Quantification of this effect is of crucial importance for correct calibration of the <sup>14</sup>C ages of marine-influenced samples to the calendrical timescale. This is fundamental to the construction of archaeological and palaeoenvironmental chronologies when such samples are employed in <sup>14</sup>C analysis. Quantitative measurements of temporal variations in regional marine reservoir ages also have the potential to be used as a measure of process changes within Earth surface systems, due to their link with climatic and oceanic changes. The various approaches to quantification of the marine radiocarbon reservoir effect are assessed, focusing particularly on the North Atlantic Ocean. Currently, the global average marine reservoir age of surface waters, R(t), is c. 400 radiocarbon years; however, regional values deviate from this as a function of climate and oceanic circulation systems. These local deviations from R(t) are expressed as +R values. Hence, polar waters exhibit greater reservoir ages (δR = c. +400 to +800 <sup>14</sup>C y) than equatorial waters (δR = c. 0 <sup>14</sup>C y). Observed temporal variations in δR appear to reflect climatic and oceanographic changes. We assess three approaches to quantification of marine reservoir effects using known age samples (from museum collections), tephra isochrones (present onshore/offshore) and paired marine/terrestrial samples (from the same context in, for example, archaeological sites). The strengths and limitations of these approaches are evaluated using examples from the North Atlantic region. It is proposed that, with a suitable protocol, accelerator mass spectrometry (AMS) measurements on paired, short-lived, single entity marine and terrestrial samples from archaeological deposits is the most promising approach to constraining changes over at least the last 5 ky BP

    Male circumcision and prevalence of genital human papillomavirus infection in men : a multinational study

    Get PDF
    Background: Accumulated evidence from epidemiological studies and more recently from randomized controlled trials suggests that male circumcision (MC) may substantially protect against genital HPV infection in men. The purpose of this study was to assess the association between MC and genital HPV infection in men in a large multinational study. Methods: A total of 4072 healthy men ages 18-70 years were enrolled in a study conducted in Brazil, Mexico, and the United States. Enrollment samples combining exfoliated cells from the coronal sulcus, glans penis, shaft, and scrotum were analyzed for the presence and genotyping of HPV DNA by PCR and linear array methods. Prevalence ratios (PR) were used to estimate associations between MC and HPV detection adjusting for potential confounders. Results: MC was not associated with overall prevalence of any HPV, oncogenic HPV types or unclassified HPV types. However, MC was negatively associated with non-oncogenic HPV infections (PR 0.85, 95% confident interval: 0.76-0.95), in particular for HPV types 11, 40, 61, 71, and 81. HPV 16, 51, 62, and 84 were the most frequently identified genotypes regardless of MC status. Conclusions: This study shows no overall association between MC and genital HPV infections in men, except for certain non-oncogenic HPV types for which a weak association was found. However, the lack of association with MC might be due to the lack of anatomic site specific HPV data, for example the glans penis, the area expected to be most likely protected by MC

    Observation of an Excited Bc+ State

    Get PDF
    Using pp collision data corresponding to an integrated luminosity of 8.5 fb-1 recorded by the LHCb experiment at center-of-mass energies of s=7, 8, and 13 TeV, the observation of an excited Bc+ state in the Bc+π+π- invariant-mass spectrum is reported. The observed peak has a mass of 6841.2±0.6(stat)±0.1(syst)±0.8(Bc+) MeV/c2, where the last uncertainty is due to the limited knowledge of the Bc+ mass. It is consistent with expectations of the Bc∗(2S31)+ state reconstructed without the low-energy photon from the Bc∗(1S31)+→Bc+Îł decay following Bc∗(2S31)+→Bc∗(1S31)+π+π-. A second state is seen with a global (local) statistical significance of 2.2σ (3.2σ) and a mass of 6872.1±1.3(stat)±0.1(syst)±0.8(Bc+) MeV/c2, and is consistent with the Bc(2S10)+ state. These mass measurements are the most precise to date

    Bose-Einstein correlations of same-sign charged pions in the forward region in pp collisions at √s=7 TeV

    Get PDF
    Bose-Einstein correlations of same-sign charged pions, produced in protonproton collisions at a 7 TeV centre-of-mass energy, are studied using a data sample collected by the LHCb experiment. The signature for Bose-Einstein correlations is observed in the form of an enhancement of pairs of like-sign charged pions with small four-momentum difference squared. The charged-particle multiplicity dependence of the Bose-Einstein correlation parameters describing the correlation strength and the size of the emitting source is investigated, determining both the correlation radius and the chaoticity parameter. The measured correlation radius is found to increase as a function of increasing charged-particle multiplicity, while the chaoticity parameter is seen to decreas
    • 

    corecore