161 research outputs found
Size Control in the Nanoprecipitation Process of Stable Iodine (127I) Using Microchannel Reactor—Optimization by Artificial Neural Networks
In this study, nanosuspension of stable iodine (127I) was prepared by nanoprecipitation process in microfluidic devices. Then, size of particles was optimized using artificial neural networks (ANNs) modeling. The size of prepared particles was evaluated by dynamic light scattering. The response surfaces obtained from ANNs model illustrated the determining effect of input variables (solvent and antisolvent flow rate, surfactant concentration, and solvent temperature) on the output variable (nanoparticle size). Comparing the 3D graphs revealed that solvent and antisolvent flow rate had reverse relation with size of nanoparticles. Also, those graphs indicated that the solvent temperature at low values had an indirect relation with size of stable iodine (127I) nanoparticles, while at the high values, a direct relation was observed. In addition, it was found that the effect of surfactant concentration on particle size in the nanosuspension of stable iodine (127I) was depended on the solvent temperature. © 2015, American Association of Pharmaceutical Scientists
Introduction to Magnetic Monopoles
One of the most basic properties of magnetism is that a magnet always has two
poles, north and south, which cannot be separated into isolated poles, i.e.,
magnetic monopoles. However, there are strong theoretical arguments why
magnetic monopoles should exist. In spite of extensive searches they have not
been found, but they have nevertheless played a central role in our
understanding of physics at the most fundamental level.Comment: 22 pages, 7 figures. To be published in Contemporary Physic
An improved method for measuring muon energy using the truncated mean of dE/dx
The measurement of muon energy is critical for many analyses in large
Cherenkov detectors, particularly those that involve separating
extraterrestrial neutrinos from the atmospheric neutrino background. Muon
energy has traditionally been determined by measuring the specific energy loss
(dE/dx) along the muon's path and relating the dE/dx to the muon energy.
Because high-energy muons (E_mu > 1 TeV) lose energy randomly, the spread in
dE/dx values is quite large, leading to a typical energy resolution of 0.29 in
log10(E_mu) for a muon observed over a 1 km path length in the IceCube
detector. In this paper, we present an improved method that uses a truncated
mean and other techniques to determine the muon energy. The muon track is
divided into separate segments with individual dE/dx values. The elimination of
segments with the highest dE/dx results in an overall dE/dx that is more
closely correlated to the muon energy. This method results in an energy
resolution of 0.22 in log10(E_mu), which gives a 26% improvement. This
technique is applicable to any large water or ice detector and potentially to
large scintillator or liquid argon detectors.Comment: 12 pages, 16 figure
Multimessenger astronomy with the Einstein Telescope
Gravitational waves (GWs) are expected to play a crucial role in the
development of multimessenger astrophysics. The combination of GW observations
with other astrophysical triggers, such as from gamma-ray and X-ray satellites,
optical/radio telescopes, and neutrino detectors allows us to decipher science
that would otherwise be inaccessible. In this paper, we provide a broad review
from the multimessenger perspective of the science reach offered by the third
generation interferometric GW detectors and by the Einstein Telescope (ET) in
particular. We focus on cosmic transients, and base our estimates on the
results obtained by ET's predecessors GEO, LIGO, and Virgo.Comment: 26 pages. 3 figures. Special issue of GRG on the Einstein Telescope.
Minor corrections include
Detecting a stochastic gravitational wave background with the Laser Interferometer Space Antenna
The random superposition of many weak sources will produce a stochastic
background of gravitational waves that may dominate the response of the LISA
(Laser Interferometer Space Antenna) gravitational wave observatory. Unless
something can be done to distinguish between a stochastic background and
detector noise, the two will combine to form an effective noise floor for the
detector. Two methods have been proposed to solve this problem. The first is to
cross-correlate the output of two independent interferometers. The second is an
ingenious scheme for monitoring the instrument noise by operating LISA as a
Sagnac interferometer. Here we derive the optimal orbital alignment for
cross-correlating a pair of LISA detectors, and provide the first analytic
derivation of the Sagnac sensitivity curve.Comment: 9 pages, 11 figures. Significant changes to the noise estimate
All-particle cosmic ray energy spectrum measured with 26 IceTop stations
We report on a measurement of the cosmic ray energy spectrum with the IceTop
air shower array, the surface component of the IceCube Neutrino Observatory at
the South Pole. The data used in this analysis were taken between June and
October, 2007, with 26 surface stations operational at that time, corresponding
to about one third of the final array. The fiducial area used in this analysis
was 0.122 km^2. The analysis investigated the energy spectrum from 1 to 100 PeV
measured for three different zenith angle ranges between 0{\deg} and 46{\deg}.
Because of the isotropy of cosmic rays in this energy range the spectra from
all zenith angle intervals have to agree. The cosmic-ray energy spectrum was
determined under different assumptions on the primary mass composition. Good
agreement of spectra in the three zenith angle ranges was found for the
assumption of pure proton and a simple two-component model. For zenith angles
{\theta} < 30{\deg}, where the mass dependence is smallest, the knee in the
cosmic ray energy spectrum was observed between 3.5 and 4.32 PeV, depending on
composition assumption. Spectral indices above the knee range from -3.08 to
-3.11 depending on primary mass composition assumption. Moreover, an indication
of a flattening of the spectrum above 22 PeV were observed.Comment: 38 pages, 17 figure
Evidence for a mixed mass composition at the `ankle' in the cosmic-ray spectrum
We report a first measurement for ultra-high energy cosmic rays of the
correlation between the depth of shower maximum and the signal in the water
Cherenkov stations of air-showers registered simultaneously by the fluorescence
and the surface detectors of the Pierre Auger Observatory. Such a correlation
measurement is a unique feature of a hybrid air-shower observatory with
sensitivity to both the electromagnetic and muonic components. It allows an
accurate determination of the spread of primary masses in the cosmic-ray flux.
Up till now, constraints on the spread of primary masses have been dominated by
systematic uncertainties. The present correlation measurement is not affected
by systematics in the measurement of the depth of shower maximum or the signal
in the water Cherenkov stations. The analysis relies on general characteristics
of air showers and is thus robust also with respect to uncertainties in
hadronic event generators. The observed correlation in the energy range around
the `ankle' at differs significantly from
expectations for pure primary cosmic-ray compositions. A light composition made
up of proton and helium only is equally inconsistent with observations. The
data are explained well by a mixed composition including nuclei with mass . Scenarios such as the proton dip model, with almost pure compositions, are
thus disfavoured as the sole explanation of the ultrahigh-energy cosmic-ray
flux at Earth.Comment: Published version. Added journal reference and DOI. Added Report
Numbe
The global, regional, and national burden of pancreatic cancer and its attributable risk factors in 195 countries and territories, 1990-2017: a systematic analysis for the Global Burden of Disease Study 2017
Background: Worldwide, both the incidence and death rates of pancreatic cancer are increasing. Evaluation of pancreatic cancer burden and its global, regional, and national patterns is crucial to policy making and better resource allocation for controlling pancreatic cancer risk factors, developing early detection methods, and providing faster and more effective treatments. Methods: Vital registration, vital registration sample, and cancer registry data were used to generate mortality, incidence, and disability-adjusted life-years (DALYs) estimates. We used the comparative risk assessment framework to estimate the proportion of deaths attributable to risk factors for pancreatic cancer: smoking, high fasting plasma glucose, and high body-mass index. All of the estimates were reported as counts and age-standardised rates per 100 000 person-years. 95% uncertainty intervals (UIs) were reported for all estimates. Findings: In 2017, there were 448 000 (95% UI 439 000\u2013456 000) incident cases of pancreatic cancer globally, of which 232 000 (210 000\u2013221 000; 51\ub79%) were in males. The age-standardised incidence rate was 5\ub70 (4\ub79\u20135\ub71) per 100 000 person-years in 1990 and increased to 5\ub77 (5\ub76\u20135\ub78) per 100 000 person-years in 2017. There was a 2\ub73 times increase in number of deaths for both sexes from 196 000 (193 000\u2013200 000) in 1990 to 441 000 (433 000\u2013449 000) in 2017. There was a 2\ub71 times increase in DALYs due to pancreatic cancer, increasing from 4\ub74 million (4\ub73\u20134\ub75) in 1990 to 9\ub71 million (8\ub79\u20139\ub73) in 2017. The age-standardised death rate of pancreatic cancer was highest in the high-income super-region across all years from 1990 to 2017. In 2017, the highest age-standardised death rates were observed in Greenland (17\ub74 [15\ub78\u201319\ub70] per 100 000 person-years) and Uruguay (12\ub71 [10\ub79\u201313\ub75] per 100 000 person-years). These countries also had the highest age-standardised death rates in 1990. Bangladesh (1\ub79 [1\ub75\u20132\ub73] per 100 000 person-years) had the lowest rate in 2017, and S\ue3o Tom\ue9 and Pr\uedncipe (1\ub73 [1\ub71\u20131\ub75] per 100 000 person-years) had the lowest rate in 1990. The numbers of incident cases and deaths peaked at the ages of 65\u201369 years for males and at 75\u201379 years for females. Age-standardised pancreatic cancer deaths worldwide were primarily attributable to smoking (21\ub71% [18\ub78\u201323\ub77]), high fasting plasma glucose (8\ub79% [2\ub71\u201319\ub74]), and high body-mass index (6\ub72% [2\ub75\u201311\ub74]) in 2017. Interpretation: Globally, the number of deaths, incident cases, and DALYs caused by pancreatic cancer has more than doubled from 1990 to 2017. The increase in incidence of pancreatic cancer is likely to continue as the population ages. Prevention strategies should focus on modifiable risk factors. Development of screening programmes for early detection and more effective treatment strategies for pancreatic cancer are needed. Funding: Bill & Melinda Gates Foundation
- …