139 research outputs found
New antineutrino energy spectra predictions from the summation of beta decay branches of the fission products
In this paper, we study the impact of the inclusion of the recently measured
beta decay properties of the Tc, Mo, and
Nb nuclei in an updated calculation of the antineutrino energy spectra
of the four fissible isotopes U, and Pu. These
actinides are the main contributors to the fission processes in Pressurized
Water Reactors. The beta feeding probabilities of the above-mentioned Tc, Mo
and Nb isotopes have been found to play a major role in the component
of the decay heat of Pu, solving a large part of the
discrepancy in the 4 to 3000\,s range. They have been measured using the Total
Absorption Technique (TAS), avoiding the Pandemonium effect. The calculations
are performed using the information available nowadays in the nuclear
databases, summing all the contributions of the beta decay branches of the
fission products. Our results provide a new prediction of the antineutrino
energy spectra of U, Pu and in particular of U for
which no measurement has been published yet. We conclude that new TAS
measurements are mandatory to improve the reliability of the predicted spectra.Comment: 10 pages, 2 figure
Antineutrino emission and gamma background characteristics from a thermal research reactor
The detailed understanding of the antineutrino emission from research
reactors is mandatory for any high sensitivity experiments either for
fundamental or applied neutrino physics, as well as a good control of the gamma
and neutron backgrounds induced by the reactor operation. In this article, the
antineutrino emission associated to a thermal research reactor: the OSIRIS
reactor located in Saclay, France, is computed in a first part. The calculation
is performed with the summation method, which sums all the contributions of the
beta decay branches of the fission products, coupled for the first time with a
complete core model of the OSIRIS reactor core. The MCNP Utility for Reactor
Evolution code was used, allowing to take into account the contributions of all
beta decayers in-core. This calculation is representative of the isotopic
contributions to the antineutrino flux which can be found at research reactors
with a standard 19.75\% enrichment in U. In addition, the required
off-equilibrium corrections to be applied to converted antineutrino energy
spectra of uranium and plutonium isotopes are provided. In a second part, the
gamma energy spectrum emitted at the core level is provided and could be used
as an input in the simulation of any reactor antineutrino detector installed at
such research facilities. Furthermore, a simulation of the core surrounded by
the pool and the concrete shielding of the reactor has been developed in order
to propagate the emitted gamma rays and neutrons from the core. The origin of
these gamma rays and neutrons is discussed and the associated energy spectrum
of the photons transported after the concrete walls is displayed.Comment: 14 pages, 11 figures, Data in Appendix A and B (13 pages
SoLid : Search for Oscillations with Lithium-6 Detector at the SCK-CEN BR2 reactor
Sterile neutrinos have been considered as a possible explanation for the recent reactor and Gallium anomalies arising from reanalysis of reactor flux and calibration data of previous neutrino experiments. A way to test this hypothesis is to look for distortions of the anti-neutrino energy caused by oscillation from active to sterile neutrino at close stand-off (similar to 6-8m) of a compact reactor core. Due to the low rate of anti-neutrino interactions the main challenge in such measurement is to control the high level of gamma rays and neutron background.
The SoLid experiment is a proposal to search for active-to-sterile anti-neutrino oscillation at very short baseline of the SCK center dot CEN BR2 research reactor.
This experiment uses a novel approach to detect anti-neutrino with a highly segmented detector based on Lithium-6. With the combination of high granularity, high neutron-gamma discrimination using 6LiF:ZnS(Ag) and precise localization of the Inverse Beta Decay products, a better experimental sensitivity can be achieved compared to other state-of-the-art technology. This compact system requires minimum passive shielding allowing for very close stand off to the reactor. The experimental set up of the SoLid experiment and the BR2 reactor will be presented. The new principle of neutrino detection and the detector design with expected performance will be described. The expected sensitivity to new oscillations of the SoLid detector as well as the first measurements made with the 8 kg prototype detector deployed at the BR2 reactor in 2013-2014 will be reported
Total Absorption Spectroscopy Study of Rb Decay: A Major Contributor to Reactor Antineutrino Spectrum Shape
The antineutrino spectra measured in recent experiments at reactors are
inconsistent with calculations based on the conversion of integral beta spectra
recorded at the ILL reactor. Rb makes the dominant contribution to the
reactor spectrum in the 5-8 MeV range but its decay properties are in question.
We have studied Rb decay with total absorption spectroscopy. Previously
unobserved beta feeding was seen in the 4.5-5.5 region and the GS to GS feeding
was found to be 87.5(25)%. The impact on the reactor antineutrino spectra
calculated with the summation method is shown and discussed.Comment: 6 pages, 3 figure
Online Monitoring of the Osiris Reactor with the Nucifer Neutrino Detector
Originally designed as a new nuclear reactor monitoring device, the Nucifer
detector has successfully detected its first neutrinos. We provide the second
shortest baseline measurement of the reactor neutrino flux. The detection of
electron antineutrinos emitted in the decay chains of the fission products,
combined with reactor core simulations, provides an new tool to assess both the
thermal power and the fissile content of the whole nuclear core and could be
used by the Inter- national Agency for Atomic Energy (IAEA) to enhance the
Safeguards of civil nuclear reactors. Deployed at only 7.2m away from the
compact Osiris research reactor core (70MW) operating at the Saclay research
centre of the French Alternative Energies and Atomic Energy Commission (CEA),
the experiment also exhibits a well-suited configuration to search for a new
short baseline oscillation. We report the first results of the Nucifer
experiment, describing the performances of the 0.85m3 detector remotely
operating at a shallow depth equivalent to 12m of water and under intense
background radiation conditions. Based on 145 (106) days of data with reactor
ON (OFF), leading to the detection of an estimated 40760 electron
antineutrinos, the mean number of detected antineutrinos is 281 +- 7(stat) +-
18(syst) electron antineutrinos/day, in agreement with the prediction 277(23)
electron antineutrinos/day. Due the the large background no conclusive results
on the existence of light sterile neutrinos could be derived, however. As a
first societal application we quantify how antineutrinos could be used for the
Plutonium Management and Disposition Agreement.Comment: 22 pages, 16 figures - Version
Light Sterile Neutrinos: A White Paper
This white paper addresses the hypothesis of light sterile neutrinos based on
recent anomalies observed in neutrino experiments and the latest astrophysical
data
Indication for the disappearance of reactor electron antineutrinos in the Double Chooz experiment
The Double Chooz Experiment presents an indication of reactor electron
antineutrino disappearance consistent with neutrino oscillations. A ratio of
0.944 0.016 (stat) 0.040 (syst) observed to predicted events was
obtained in 101 days of running at the Chooz Nuclear Power Plant in France,
with two 4.25 GW reactors. The results were obtained from a single 10
m fiducial volume detector located 1050 m from the two reactor cores. The
reactor antineutrino flux prediction used the Bugey4 measurement as an anchor
point. The deficit can be interpreted as an indication of a non-zero value of
the still unmeasured neutrino mixing parameter \sang. Analyzing both the rate
of the prompt positrons and their energy spectrum we find \sang = 0.086
0.041 (stat) 0.030 (syst), or, at 90% CL, 0.015 \sang 0.16.Comment: 7 pages, 4 figures, (new version after PRL referee's comments
Precision muon reconstruction in Double Chooz
We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of the liquid scintillator viewed by PMTs, and an Outer Veto above these made of crossed scintillator strips. Muons are reconstructed by their Outer Veto hit positions along with timing information from the other two detector volumes. All muons are fit under the hypothesis that they are through-going and ultrarelativistic. If the energy depositions suggest that the muon may have stopped, the reconstruction fits also for this hypothesis and chooses between the two via the relative goodness-of-fit. In the ideal case of a through-going muon intersecting the center of the detector, the resolution is ~40mm in each transverse dimension. High quality muon reconstruction is an important tool for reducing the impact of the cosmogenic isotope background in Double Chooz. © 2014 Elsevier B.V
- …