3,149 research outputs found

    Evaporative CO2 cooling using microchannels etched in silicon for the future LHCb vertex detector

    Full text link
    The extreme radiation dose received by vertex detectors at the Large Hadron Collider dictates stringent requirements on their cooling systems. To be robust against radiation damage, sensors should be maintained below -20 degree C and at the same time, the considerable heat load generated in the readout chips and the sensors must be removed. Evaporative CO2 cooling using microchannels etched in a silicon plane in thermal contact with the readout chips is an attractive option. In this paper, we present the first results of microchannel prototypes with circulating, two-phase CO2 and compare them to simulations. We also discuss a practical design of upgraded VELO detector for the LHCb experiment employing this approach.Comment: 12 page

    Charm production nearby threshold in pA-interactions at 70 GeV

    Full text link
    The results of the SERP-E-184 experiment at the U-70 accelerator (IHEP, Protvino) are presented. Interactions of the 70 GeV proton beam with C, Si and Pb targets were studied to detect decays of charmed D0D^0, D0\overline D^0, D+D^+, DD^- mesons and Λc+\Lambda _c^+ baryon near their production threshold. Measurements of lifetimes and masses are shown a good agreement with PDG data. The inclusive cross sections of charm production and their A-dependencies were obtained. The yields of these particles are compared with the theoretical predictions and the data of other experiments. The measured cross section of the total open charm production (σtot(cc)\sigma _{\mathrm {tot}}(c\overline c) = 7.1 ±\pm 2.3(stat) ±\pm 1.4(syst) μ\mu b/nucleon) at the collision c.m. energy s\sqrt {s} = 11.8 GeV is well above the QCD model predictions. The contributions of different species of charmed particles to the total cross section of the open charm production in proton-nucleus interactions vary with energy.Comment: 4 pages, 6 pages, 38th International Conference on High Energy Physics 3-10 August 2016, Chicago, US

    Characterisation of Medipix3 Silicon Detectors in a Charged-Particle Beam

    Get PDF
    While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and shown to be in agreement with simulation, demonstrating the suitability of the Medipix3 ASIC as a tool for characterising pixel sensors.Comment: 16 pages, 13 figure

    Observation of narrow baryon resonance decaying into pKs0pK^0_s in pA-interactions at 70GeV/c70 GeV/c with SVD-2 setup

    Full text link
    SVD-2 experiment data have been analyzed to search for an exotic baryon state, the Θ+\Theta^+-baryon, in a pKs0pK^0_s decay mode at 70GeV/c70 GeV/c on IHEP accelerator. The reaction pApKs0+XpA \to pK^0_s+X with a limited multiplicity was used in the analysis. The pKs0pK^0_s invariant mass spectrum shows a resonant structure with M=1526±3(stat.)±3(syst.)MeV/c2M=1526\pm3(stat.)\pm 3(syst.) MeV/c^2 and Γ<24MeV/c2\Gamma < 24 MeV/c^2. The statistical significance of this peak was estimated to be of 5.6σ5.6 \sigma. The mass and width of the resonance is compatible with the recently reported Θ+\Theta^+- baryon with positive strangeness which was predicted as an exotic pentaquark (uuddsˉuudd\bar{s}) baryon state. The total cross section for Θ+\Theta^+ production in pN-interactions for XF0X_F\ge 0 was estimated to be (30÷120)μb(30\div120) \mu b and no essential deviation from A-dependence for inelastic events (A0.7)(\sim A^{0.7}) was found.Comment: 8 pages, 7 figures, To be submitted to Yadernaya Fizika. v3-v5 - Some references added, minor typos correcte

    Properties of Neutral Charmed Mesons in Proton--Nucleus Interactions at 70 GeV

    Full text link
    The results of treatment of data obtained in the SERP-E-184experiment "Investigation of mechanisms of the production of charmed particles in proton-nucleus interactions at 70 GeV and their decays" by irradiating the active target of the SVD-2 facility consisting of carbon, silicon, and lead plates, are presented. After separating a signal from the two-particle decay of neutral charmed mesons and estimating the cross section for charm production at a threshold energy {\sigma}(c\v{c})=7.1 \pm 2.4(stat.) \pm 1.4(syst.) \mub/nucleon, some properties of D mesons are investigated. These include the dependence of the cross section on the target mass number (its A dependence); the behavior of the differential cross sections d{\sigma}/dpt2 and d{\sigma}/dxF; and the dependence of the parameter {\alpha} on the kinematical variables xF, pt2, and plab. The experimental results in question are compared with predictions obtained on the basis of the FRITIOF7.02 code.Comment: 9 pages, 9 figures,3 table

    Radiation damage in the LHCb vertex locator

    Get PDF
    The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately 45 × 1012 1 MeV neutron equivalent (1 MeV neq). At the operational sensor temperature of approximately −7 °C, the average rate of sensor current increase is 18 μA per fb−1, in excellent agreement with predictions. The silicon effective bandgap has been determined using current versus temperature scan data after irradiation, with an average value of Eg = 1.16±0.03±0.04 eV obtained. The first observation of n+-on-n sensor type inversion at the LHC has been made, occurring at a fluence of around 15 × 1012 of 1 MeV neq. The only n+-on-p sensors in use at the LHC have also been studied. With an initial fluence of approximately 3 × 1012 1 MeV neq, a decrease in the Effective Depletion Voltage (EDV) of around 25 V is observed. Following this initial decrease, the EDV increases at a comparable rate to the type inverted n+-on-n type sensors, with rates of (1.43±0.16) × 10−12 V/ 1 MeV neq and (1.35±0.25) × 10−12 V/ 1 MeV neq measured for n+-on-p and n+-on-n type sensors, respectively. A reduction in the charge collection efficiency due to an unexpected effect involving the second metal layer readout lines is observed
    corecore