4,206 research outputs found

    Modelling and verifying IEEE Std 11073-20601 session setup using mCRL2

    Get PDF
    In this paper we advocate that formal verification should bea part of the development of a communication standard;in a short period of time issues areuncovered that have been in the standard for a number of years, and allsubtleties in the correctness of the protocol are understood.We model and verify the session setup protocolthat is part of the IEEE 11073-20601:2008 standard for communication betweenpersonal health devices.We identify a number of issues present in the standards document.Discussion with a member of the standards committee unveiled that most, but notall, of the identified issues are fixed in the IEEE 11073-20601:2010 version ofthe standard.In addition, the correctness of the protocol, including the fixes, is assessed.For this, properties of the session setup protocol are formulated, and usingthe model checker mCRL2 it is verified whether the model satisfies theseproperties.We show that the session setup protocol is flawed, and propose a straightforwardway to fix this issue

    Examining the content and moderators of women's fears for giving birth: A meta-synthesis

    Get PDF
    Aims and objectives: This meta‐synthesis aimed to identify key elements contributing to FOC derived from women's own reports. Background: Fear of childbirth (FOC) encompasses fear or anxiety about giving birth, which can resemble a phobic response. FOC holds implications for women's antenatal and postnatal well‐being, and decisions made about the birth but a clear definition of the construct does not exist. Method: A meta‐synthesis was conducted by searching databases (Web of Knowledge, CINAHL, EBSCO, MEDLINE, PsychInfo and PsychArticles) for qualitative studies describing women's perspectives with respect to fear, anxiety, concerns, phobia or stress about birth. A total of 25 papers, reporting findings from 24 studies, fulfilled eligibility criteria and were included in the synthesis. Results: Six key elements of FOC were identified; fears of the unknown, potential for injury, pain, capacity to give birth, losing control and adequacy of support from care providers. A single overarching theme linking all elements was “the unpredictability of childbirth.” Three moderators of FOC were also identified; awareness of negative birthing experiences, information received about birth and support received from care providers. Conclusions: Findings highlight the role of uncertainty in the birthing process as an overarching theme underpinning women's fears. Enhancing tolerance of uncertainty may be a way to reduce women's FOC. Relevance to clinical practice: Identification of the elements and moderators of FOC provide an insight into the potential mechanisms that contribute to women's fears, which can be used to inform methods of identifying women with FOC or a basis upon which to base supportive strategies to reduce women's fears for giving birth

    Run 2 Upgrades to the CMS Level-1 Calorimeter Trigger

    Get PDF
    The CMS Level-1 calorimeter trigger is being upgraded in two stages to maintain performance as the LHC increases pile-up and instantaneous luminosity in its second run. In the first stage, improved algorithms including event-by-event pile-up corrections are used. New algorithms for heavy ion running have also been developed. In the second stage, higher granularity inputs and a time-multiplexed approach allow for improved position and energy resolution. Data processing in both stages of the upgrade is performed with new, Xilinx Virtex-7 based AMC cards.Comment: 10 pages, 7 figure

    Monitoring Response to Radiotherapy in Human Squamous Cell Cancer Bearing Nude Mice: Comparison of 2′-deoxy-2′-[18F]fluoro-d-glucose (FDG) and 3′-[18F]fluoro-3′-deoxythymidine (FLT)

    Get PDF
    Objective: The uptake of 3′-[18F]fluoro-3′- deoxythymidine (FLT), a proliferation marker, was measured before and during fractionated radiotherapy to evaluate the potential of FLT-positron emission tomography (PET) imaging as an indicator of tumor response compared to 2′-deoxy-2′-[18F]fluoro-d-glucose (FDG). Materials and Methods: Nude mice bearing established human head and neck xenografts (HNX-OE; nu/nu mice) were locally irradiated (three fractions/week; 22 Gy) using a 150-kVp unit. Multiple FDG- and FLT-PET scans were acquired during treatment. Tumor volume was determined regularly, and tissue was analyzed for biomarkers involved in tracer uptake. Results: Both groups revealed a significant decline in tumor volume (P∈<∈0.01) compared to untreated tumors. For FDG as well as for FLT, a significant decline in retention was observed at day 4. For FLT, most significant decline in retention was observed at day 12; whereas, for FDG, this was already noted at day 4. Maximum decline in tumor-to-nontumor ratios (T/NT) for FDG and FLT was 42∈±∈18% and 49∈±∈16% (mean∈± ∈SD), respectively. FLT uptake was higher then that of FDG. For FLT, statistical significant correlations were found for both tumor volume at baseline and at day 29 with T/NT and ΔT/NT. All tumors demonstrated expression of glucose transporter-1, thymidine kinase-1, and hexokinase II. No differences were found for amount of tumor cells and necrosis at the end of treatment. Conclusion: This new experimental in vivo model supports the promise of using FLT-PET, as with FDG-PET, to monitor response to external radiotherapy. This warrants further clinical studies to compare these two tracers especially in cancers treated with radiotherapy

    Performance of the CMS Regional Calorimeter Trigger

    Get PDF
    The CMS Regional Calorimeter Trigger (RCT) receives eight-bit energies and a data quality bit from the HCAL and ECAL Trigger Primitive Generators (TPGs). The RCT uses these trigger primitives to find e/Îł candidates and calculate regional calorimeter sums that are sent to the Global Calorimeter Trigger (GCT) for sorting and further processing. The RCT hardware consists of one clock distribution crate and 18 double-sided crates containing custom boards, ASICs, and backplanes. The RCT electronics have been completely installed since 2007. The RCT has been integrated into the CMS Level-1 Trigger chain. Regular runs, triggering on cosmic rays, prepare the CMS detector for the restart of the LHC. During this running, the RCT control is handled centrally by CMS Run Control and Monitor System communicating with the Trigger Supervisor. Online Data Quality Monitoring (DQM) evaluates the performance of the RCT during these runs. Offline DQM allows more detailed studies, including trigger efficiencies. These and other results from cosmicray data taking with the RCT will be presented

    Measurements of branching fraction ratios and CP-asymmetries in suppressed B^- -> D(-> K^+ pi^-)K^- and B^- -> D(-> K^+ pi^-)pi^- decays

    Get PDF
    We report the first reconstruction in hadron collisions of the suppressed decays B^- -> D(-> K^+ pi^-)K^- and B^- -> D(-> K^+ pi^-)pi^-, sensitive to the CKM phase gamma, using data from 7 fb^-1 of integrated luminosity collected by the CDF II detector at the Tevatron collider. We reconstruct a signal for the B^- -> D(-> K^+ pi^-)K^- suppressed mode with a significance of 3.2 standard deviations, and measure the ratios of the suppressed to favored branching fractions R(K) = [22.0 \pm 8.6(stat)\pm 2.6(syst)]\times 10^-3, R^+(K) = [42.6\pm 13.7(stat)\pm 2.8(syst)]\times 10^-3, R^-(K)= [3.8\pm 10.3(stat)\pm 2.7(syst]\times 10^-3, as well as the direct CP-violating asymmetry A(K) = -0.82\pm 0.44(stat)\pm 0.09(syst) of this mode. Corresponding quantities for B^- -> D(-> K^+ pi^-)pi^- decay are also reported.Comment: 8 pages, 1 figure, accepted by Phys.Rev.D Rapid Communications for Publicatio

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE
    • …
    corecore