29 research outputs found

    Flexible Neural Electrode Array Based-on Porous Graphene for Cortical Microstimulation and Sensing.

    Get PDF
    Neural sensing and stimulation have been the backbone of neuroscience research, brain-machine interfaces and clinical neuromodulation therapies for decades. To-date, most of the neural stimulation systems have relied on sharp metal microelectrodes with poor electrochemical properties that induce extensive damage to the tissue and significantly degrade the long-term stability of implantable systems. Here, we demonstrate a flexible cortical microelectrode array based on porous graphene, which is capable of efficient electrophysiological sensing and stimulation from the brain surface, without penetrating into the tissue. Porous graphene electrodes show superior impedance and charge injection characteristics making them ideal for high efficiency cortical sensing and stimulation. They exhibit no physical delamination or degradation even after 1 million biphasic stimulation cycles, confirming high endurance. In in vivo experiments with rodents, same array is used to sense brain activity patterns with high spatio-temporal resolution and to control leg muscles with high-precision electrical stimulation from the cortical surface. Flexible porous graphene array offers a minimally invasive but high efficiency neuromodulation scheme with potential applications in cortical mapping, brain-computer interfaces, treatment of neurological disorders, where high resolution and simultaneous recording and stimulation of neural activity are crucial

    Implantable Neural Probes for Brain-Machine Interfaces - Current Developments and Future Prospects

    Get PDF
    A Brain-Machine interface (BMI) allows for direct communication between the brain and machines. Neural probes for recording neural signals are among the essential components of a BMI system. In this report, we review research regarding implantable neural probes and their applications to BMIs. We first discuss conventional neural probes such as the tetrode, Utah array, Michigan probe, and electroencephalography (ECoG), following which we cover advancements in next-generation neural probes. These next-generation probes are associated with improvements in electrical properties, mechanical durability, biocompatibility, and offer a high degree of freedom in practical settings. Specifically, we focus on three key topics: (1) novel implantable neural probes that decrease the level of invasiveness without sacrificing performance, (2) multi-modal neural probes that measure both electrical and optical signals, (3) and neural probes developed using advanced materials. Because safety and precision are critical for practical applications of BMI systems, future studies should aim to enhance these properties when developing next-generation neural probes

    Optogenetic Brain Interfaces

    Get PDF
    The brain is a large network of interconnected neurons where each cell functions as a nonlinear processing element. Unraveling the mysteries of information processing in the complex networks of the brain requires versatile neurostimulation and imaging techniques. Optogenetics is a new stimulation method which allows the activity of neurons to be modulated by light. For this purpose, the cell-types of interest are genetically targeted to produce light-sensitive proteins. Once these proteins are expressed, neural activity can be controlled by exposing the cells to light of appropriate wavelengths. Optogenetics provides a unique combination of features, including multimodal control over neural function and genetic targeting of specific cell-types. Together, these versatile features combine to a powerful experimental approach, suitable for the study of the circuitry of psychiatric and neurological disorders. The advent of optogenetics was followed by extensive research aimed to produce new lines of light-sensitive proteins and to develop new technologies: for example, to control the distribution of light inside the brain tissue or to combine optogenetics with other modalities including electrophysiology, electrocorticography, nonlinear microscopy, and functional magnetic resonance imaging. In this paper, the authors review some of the recent advances in the field of optogenetics and related technologies and provide their vision for the future of the field.United States. Defense Advanced Research Projects Agency (Space and Naval Warfare Systems Center, Pacific Grant/Contract No. N66001-12-C-4025)University of Wisconsin--Madison (Research growth initiative; grant 101X254)University of Wisconsin--Madison (Research growth initiative; grant 101X172)University of Wisconsin--Madison (Research growth initiative; grant 101X213)National Science Foundation (U.S.) (MRSEC DMR-0819762)National Science Foundation (U.S.) (NSF CAREER CBET-1253890)National Institutes of Health (U.S.) (NIH/NIBIB R00 Award (4R00EB008738)National Institutes of Health (U.S.) (NIH Director’s New Innovator award (1-DP2-OD002989))Okawa Foundation (Research Grant Award)National Institutes of Health (U.S.) (NIH Director’s New Innovator Award (1DP2OD007265))National Science Foundation (U.S.) (NSF CAREER Award (1056008)Alfred P. Sloan Foundation (Fellowship)Human Frontier Science Program (Strasbourg, France) (Grant No. 1351/12)Israeli Centers of Research Excellence (I-CORE grant, program 51/11)MINERVA Foundation (Germany

    Multimodal Investigation of the Efficiency and Stability of Microstimulation using Electrodes Coated with PEDOT/CNT and Iridium Oxide

    Get PDF
    Electrical microstimulation is an invaluable tool in neuroscience research to dissect neural circuits, relate brain areas, and identify relationships between brain structure and behavior. In the clinic, electrical microstimulation has enabled partial restoration of vision, movement, sensation and autonomic functions. Recently, novel materials and new fabrication techniques of traditional metals have emerged such as iridium oxide and the conducting polymer PEDOT/CNT. These materials have demonstrated particular promise in the improvement in electrical efficiency. However, the in vivo stimulation efficiency and the in vivo stability of these materials have not been thoroughly characterized. In this dissertation, we use a multimodal approach to study the efficiency and stability of electrode-tissue interface using novel materials in microstimulation

    Titania nanotube arrays as potential interfaces for neurological prostheses

    Get PDF
    2014 Summer.Includes bibliographical references.Neural prostheses can make a dramatic improvement for those suffering from visual and auditory, cognitive, and motor control disabilities, allowing them regained functionality by the use of stimulating or recording electrical signaling. However, the longevity of these devices is limited due to the neural tissue response to the implanted device. In response to the implant penetrating the blood brain barrier and causing trauma to the tissue, the body forms a to scar to isolate the implant in order to protect the nearby tissue. The scar tissue is a result of reactive gliosis and produces an insulated sheath, encapsulating the implant. The glial sheath limits the stimulating or recording capabilities of the implant, reducing its effectiveness over the long term. A favorable interaction with this tissue would be the direct adhesion of neurons onto the contacts of the implant, and the prevention of glial encapsulation. With direct neuronal adhesion the effectiveness and longevity of the device would be significantly improved. Titania nanotube arrays, fabricated using electrochemical anodization, provide a conductive architecture capable of altering cellular response. This work focuses on the fabrication of different titania nanotube array architectures to determine how their structures and properties influence the response of neural tissue, modeled using the C17.2 murine neural stem cell subclone, and if glial encapsulation can be reduced while neuronal adhesion is promoted

    De animais a máquinas : humanos tecnicamente melhores nos imaginários de futuro da convergência tecnológica

    Get PDF
    Dissertação (mestrado)—Universidade de Brasília, Instituto de Ciências Sociais, Departamento de Sociologia, 2020.O tema desta investigação é discutir os imaginários sociais de ciência e tecnologia que emergem a partir da área da neuroengenharia, em sua relação com a Convergência Tecnológica de quatro disciplinas: Nanotecnologia, Biotecnologia, tecnologias da Informação e tecnologias Cognitivas - neurociências- (CT-NBIC). Estas áreas desenvolvem-se e são articuladas por meio de discursos que ressaltam o aprimoramento das capacidades físicas e cognitivas dos seres humanos, com o intuito de construir uma sociedade melhor por meio do progresso científico e tecnológico, nos limites das agendas de pesquisa e desenvolvimento (P&D). Objetivos: Os objetivos nesse cenário, são discutir as implicações éticas, econômicas, políticas e sociais deste modelo de sistema sociotécnico. Nos referimos, tanto as aplicações tecnológicas, quanto as consequências das mesmas na formação dos imaginários sociais, que tipo de relações se estabelecem e como são criadas dentro desse contexto. Conclusão: Concluímos na busca por refletir criticamente sobre as propostas de aprimoramento humano mediado pela tecnologia, que surgem enquanto parte da agenda da Convergência Tecnológica NBIC. No entanto, as propostas de melhoramento humano vão muito além de uma agenda de investigação. Há todo um quadro de referências filosóficas e políticas que defendem o aprimoramento da espécie, vertentes estas que se aliam a movimentos trans-humanistas e pós- humanistas, posições que são ao mesmo tempo éticas, políticas e econômicas. A partir de nossa análise, entendemos que ciência, tecnologia e política estão articuladas, em coprodução, em relação às expectativas de futuros que são esperados ou desejados. Ainda assim, acreditamos que há um espaço de diálogo possível, a partir do qual buscamos abrir propostas para o debate público sobre questões de ciência e tecnologia relacionadas ao aprimoramento da espécie humana.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)The subject of this research is to discuss the social imaginaries of science and technology that emerge from the area of neuroengineering in relation with the Technological Convergence of four disciplines: Nanotechnology, Biotechnology, Information technologies and Cognitive technologies -neurosciences- (CT-NBIC). These areas are developed and articulated through discourses that emphasize the enhancement of human physical and cognitive capacities, the intuition it is to build a better society, through the scientific and technological progress, at the limits of the research and development (R&D) agendas. Objectives: The objective in this scenery, is to discuss the ethic, economic, politic and social implications of this model of sociotechnical system. We refer about the technological applications and the consequences of them in the formation of social imaginaries as well as the kind of social relations that are created and established in this context. Conclusion: We conclude looking for critical reflections about the proposals of human enhancement mediated by the technology. That appear as a part of the NBIC technologies agenda. Even so, the proposals of human enhancement go beyond boundaries that an investigation agenda. There is a frame of philosophical and political references that defend the enhancement of the human beings. These currents that ally to the transhumanism and posthumanism movements, positions that are ethic, politic and economic at the same time. From our analysis, we understand that science, technology and politics are articulated, are in co-production, regarding the expected and desired futures. Even so, we believe that there is a space of possible dialog, from which we look to open proposals for the public discussion on questions of science and technology related to enhancement of human beings

    Long-Term Activity-Dependent Plasticity of Action Potential Propagation Delay and Amplitude in Cortical Networks

    Get PDF
    Background: The precise temporal control of neuronal action potentials is essential for regulating many brain functions. From the viewpoint of a neuron, the specific timings of afferent input from the action potentials of its synaptic partners determines whether or not and when that neuron will fire its own action potential. Tuning such input would provide a powerful mechanism to adjust neuron function and in turn, that of the brain. However, axonal plasticity of action potential timing is counter to conventional notions of stable propagation and to the dominant theories of activity-dependent plasticity focusing on synaptic efficacies. Methodology/Principal Findings: Here we show the occurrence of activity-dependent plasticity of action potentia

    Device design factors for enhancing the functionality of chronic intracortical microelectrodes

    Get PDF
    Intracortical microelectrodes are devices used in brain-computer interfaces (BCI) to help regain lost motor, sensory, and cognitive functions of individuals with neurological disorders. However, the long-term performance of microelectrode arrays is hampered by a series of inflammatory tissue responses. The consequence of the inflammatory response is the formation of a dense astroglial sheath around the vicinity of the electrode, impeding the electrical conduction between the electrode and neurons. Furthermore, due to the cascade of neuroinflammatory events, the number of neurons is significantly reduced near the electrode, manifested by decrease in signal-to-noise ratio (SNR) and the yield of electrodes. Over time, these issues eventually lead to the functional failure of the implant. This study aims to investigate mechanical intervention strategies to mitigate the effect of the biological response and prolong the lifetime of the implanted microelectrodes. First, the longitudinal recording performance of a modified site geometry was evaluated. With planar silicon microelectrodes, sites placed on the edge outperformed the sites placed on the center, demonstrated by increased number of detectable single units with enhanced longevity. Second, the stress-strain induced biological response was studied using various flexible electrodes. Flexible electrodes indeed reduced the magnitude of the biological response than the traditional stiff silicon electrodes. Past a certain flexibility level, however, the biological response did not reduce over less soft electrodes, suggesting a flexibility threshold model. Finally, the biological response of electrodes dip-coated with polyethylene glycol (PEG) was evaluated to resolve a potential confound of PEG-coating used for inserting flexible electrodes. Results suggest that dip-coating with PEG do not significantly alter the inflammatory biomarker profiles around the device. Overall, findings from assessing the above mentioned intervention strategies will help devising a complex multimodal solution for prolonging the lifetime of neural implants
    corecore