770 research outputs found

    Design and Control of Electrical Motor Drives

    Get PDF
    Dear Colleagues, I am very happy to have this Special Issue of the journal Energies on the topic of Design and Control of Electrical Motor Drives published. Electrical motor drives are widely used in the industry, automation, transportation, and home appliances. Indeed, rolling mills, machine tools, high-speed trains, subway systems, elevators, electric vehicles, air conditioners, all depend on electrical motor drives.However, the production of effective and practical motors and drives requires flexibility in the regulation of current, torque, flux, acceleration, position, and speed. Without proper modeling, drive, and control, these motor drive systems cannot function effectively.To address these issues, we need to focus on the design, modeling, drive, and control of different types of motors, such as induction motors, permanent magnet synchronous motors, brushless DC motors, DC motors, synchronous reluctance motors, switched reluctance motors, flux-switching motors, linear motors, and step motors.Therefore, relevant research topics in this field of study include modeling electrical motor drives, both in transient and in steady-state, and designing control methods based on novel control strategies (e.g., PI controllers, fuzzy logic controllers, neural network controllers, predictive controllers, adaptive controllers, nonlinear controllers, etc.), with particular attention to transient responses, load disturbances, fault tolerance, and multi-motor drive techniques. This Special Issue include original contributions regarding recent developments and ideas in motor design, motor drive, and motor control. The topics include motor design, field-oriented control, torque control, reliability improvement, advanced controllers for motor drive systems, DSP-based sensorless motor drive systems, high-performance motor drive systems, high-efficiency motor drive systems, and practical applications of motor drive systems. I want to sincerely thank authors, reviewers, and staff members for their time and efforts. Prof. Dr. Tian-Hua Liu Guest Edito

    Assessing and augmenting SCADA cyber security: a survey of techniques

    Get PDF
    SCADA systems monitor and control critical infrastructures of national importance such as power generation and distribution, water supply, transportation networks, and manufacturing facilities. The pervasiveness, miniaturisations and declining costs of internet connectivity have transformed these systems from strictly isolated to highly interconnected networks. The connectivity provides immense benefits such as reliability, scalability and remote connectivity, but at the same time exposes an otherwise isolated and secure system, to global cyber security threats. This inevitable transformation to highly connected systems thus necessitates effective security safeguards to be in place as any compromise or downtime of SCADA systems can have severe economic, safety and security ramifications. One way to ensure vital asset protection is to adopt a viewpoint similar to an attacker to determine weaknesses and loopholes in defences. Such mind sets help to identify and fix potential breaches before their exploitation. This paper surveys tools and techniques to uncover SCADA system vulnerabilities. A comprehensive review of the selected approaches is provided along with their applicability

    Classifying resilience approaches for protecting smart grids against cyber threats

    Get PDF
    Smart grids (SG) draw the attention of cyber attackers due to their vulnerabilities, which are caused by the usage of heterogeneous communication technologies and their distributed nature. While preventing or detecting cyber attacks is a well-studied field of research, making SG more resilient against such threats is a challenging task. This paper provides a classification of the proposed cyber resilience methods against cyber attacks for SG. This classification includes a set of studies that propose cyber-resilient approaches to protect SG and related cyber-physical systems against unforeseen anomalies or deliberate attacks. Each study is briefly analyzed and is associated with the proper cyber resilience technique which is given by the National Institute of Standards and Technology in the Special Publication 800-160. These techniques are also linked to the different states of the typical resilience curve. Consequently, this paper highlights the most critical challenges for achieving cyber resilience, reveals significant cyber resilience aspects that have not been sufficiently considered yet and, finally, proposes scientific areas that should be further researched in order to enhance the cyber resilience of SG.Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. Funding for open access charge: Universidad de Málaga / CBUA

    Integration of Fuel Cell Technologies in Renewable-Energy-Based Microgrids Optimizing Operational Costs and Durability

    Get PDF
    In this paper, a Model Predictive Control (MPC) approach is proposed to manage a grid-tied hydrogen microgrid (μG) . The μG testbed is equipped with a 1-kW polymer electrolyte membrane (PEM) electrolyzer and a 1.5-kW PEM fuel cell as main equipment. In particular, we present a formulation that includes the cost of the electricity exported/imported, the aging of the components, and the operational constraints. The control objective is to satisfy user demand, as well as extend the lifespan of expensive equipment, as is the case of the fuel cell or the electrolyzer. μG performance is investigated under realistic scenarios in three experiments. The experimental results illustrate how the proposed control system is able to manage the fuel cell and the electrolyzer through smooth power references, as well as to satisfy the power demanded. Finally, benchmarking is carried out between hysteresis band (HB) control and the proposed MPC in regard to efficiency and cost of the operation. The results obtained show that the MPC approach is more effective than HB for this type of μG , with a reduction in operation cost of up to 30%

    Software Algorithms to Coordinate and Improve Voltage Sag Ridethrough Capabilities of Networked Industrial Processes

    Get PDF
    For those who design, operate, and troubleshoot industrial processes, electric power quality is a subject that requires much consideration. Processes that use electronic sensors, actuators, and computation devices are heavily reliant on a stable, consistent input power source. When a power quality event such as a voltage fluctuation occurs, automation equipment often behaves unpredictably and causes process malfunction or failure. Because industrial power consumers often blame their electric utility for these events, some utilities offer process susceptibility studies as a service for their customers. During a typical study, utility technicians and engineers perform in-house tests on suspect components or systems using voltage sag generating equipment. These tests determine device malfunction thresholds and establish an event failure timeline. Test results provide data for applying mitigation solutions, where the most critical or susceptible loads receive a higher priority for improvement. While effective, this approach often requires the addition of costly hardware. This study presents novel software algorithms that coordinate and improve process ridethrough capabilities of network connected industrial processes. An add-on PC interfacing with an automation network executes a routine that detects voltage sags, performs a fast measurement of sag parameters, and determines an expected process response. Rather than implement a `cure all\u27 reaction for every disturbance scenario, mitigation routines are executed based upon the expected response. Underlying design constraints of this study are to minimize or avoid the installation of conventional ridethrough hardware and adhere to a software architecture that is unintrusive to existing controllers. Voltage sag detection is performed with a real-time analysis of incoming voltages and is triggered from RMS voltage derivative threshold crossings. Having recognized the presence of a voltage sag, the algorithm determines the sag magnitude with a peak detection method, and can associate the measured magnitude/phase combination with previously recorded process data. Either the sag characteristics or historical process response data is then analyzed to determine the expected process response. Sags that can potentially force motor drives to trip offline cause the process to respond to an expected shutdown. Voltage sag magnitude/phasing combinations that have been shown to cause no process disruption are ignored. Combinations which have caused only instrument signal corruption and significant process variable deviations trigger the mitigation routine to address faulted control signals only. Drive fault mitigation responses consist of a software-only drive coast routine and an improved drive coast routine requiring the addition of basic switching hardware. Out of tolerance process errors are mitigated with output control command substitution or input signal substitution routines. Verification of software functionality is achieved with an experimental automated process - - a textile unwind/rewind system that operates at a controlled linespeed and tension. Detailed analysis and simulation is performed on both component and system-wide levels. Unmitigated and mitigated process voltage sag responses are recorded and matched with the theoretical process model. Although customization is required to apply the algorithms to the specific design of the textile tension control process, experimentation with this test bed system serves as a satisfactory proof of concept for the software routines. As a result, the methods developed in this study can improve the task of process power quality mitigation by customizing solutions for individual processes, avoiding the application of power quality mitigation solutions where they are not required, coordinating corrective actions by utilizing existing automation network functionality, and ultimately reducing the need for costly hardware installation and maintenance

    Introduction of programmable logic controller in industrial engineering curriculum

    Get PDF
    Recent trends in process control and industrial automation scenarios have resulted in the emergence of many pioneering techniques that have revolutionized the manufacturing industry. In order to maintain quality and precision, advances have been associated with the increasing use of microprocessors in process control applications. Most of the industrial process control systems utilize Programmable Logic Controllers (PLC). Also due to the increase in internet usage and recent innovations in PLC software, remote monitoring and PLC control of process through the internet is also a recent trend. This thesis presents course/lab material for integration in the Industrial Engineering curriculum. The course/lab content was designed to improve the student\u27s knowledge and to broaden the industrial engineering curriculum at West Virginia University (WVU). This thesis proposes the use of inexpensive T100MD+ PLCs. A traffic light control system was developed to introduce the fundamental concepts of Boolean algebra and real-time control. A series of control exercises can be carried on the traffic light system. A temperature sensitive system was also developed. Students can test various PID control strategies on this hardware/software platform. Students will also have the ability to control the process via the internet

    FAST : a fault detection and identification software tool

    Get PDF
    The aim of this work is to improve the reliability and safety of complex critical control systems by contributing to the systematic application of fault diagnosis. In order to ease the utilization of fault detection and isolation (FDI) tools in the industry, a systematic approach is required to allow the process engineers to analyze a system from this perspective. In this way, it should be possible to analyze this system to find if it provides the required fault diagnosis and redundancy according to the process criticality. In addition, it should be possible to evaluate what-if scenarios by slightly modifying the process (f.i. adding sensors or changing their placement) and evaluating the impact in terms of the fault diagnosis and redundancy possibilities. Hence, this work proposes an approach to analyze a process from the FDI perspective and for this purpose provides the tool FAST which covers from the analysis and design phase until the final FDI supervisor implementation in a real process. To synthesize the process information, a very simple format has been defined based on XML. This format provides the needed information to systematically perform the Structural Analysis of that process. Any process can be analyzed, the only restriction is that the models of the process components need to be available in the FAST tool. The processes are described in FAST in terms of process variables, components and relations and the tool performs the structural analysis of the process obtaining: (i) the structural matrix, (ii) the perfect matching, (iii) the analytical redundancy relations (if any) and (iv) the fault signature matrix. To aid in the analysis process, FAST can operate stand alone in simulation mode allowing the process engineer to evaluate the faults, its detectability and implement changes in the process components and topology to improve the diagnosis and redundancy capabilities. On the other hand, FAST can operate on-line connected to the process plant through an OPC interface. The OPC interface enables the possibility to connect to almost any process which features a SCADA system for supervisory control. When running in on-line mode, the process is monitored by a software agent known as the Supervisor Agent. FAST has also the capability of implementing distributed FDI using its multi-agent architecture. The tool is able to partition complex industrial processes into subsystems, identify which process variables need to be shared by each subsystem and instantiate a Supervision Agent for each of the partitioned subsystems. The Supervision Agents once instantiated will start diagnosing their local components and handle the requests to provide the variable values which FAST has identified as shared with other agents to support the distributed FDI process.Per tal de facilitar la utilització d'eines per la detecció i identificació de fallades (FDI) en la indústria, es requereix un enfocament sistemàtic per permetre als enginyers de processos analitzar un sistema des d'aquesta perspectiva. D'aquesta forma, hauria de ser possible analitzar aquest sistema per determinar si proporciona el diagnosi de fallades i la redundància d'acord amb la seva criticitat. A més, hauria de ser possible avaluar escenaris de casos modificant lleugerament el procés (per exemple afegint sensors o canviant la seva localització) i avaluant l'impacte en quant a les possibilitats de diagnosi de fallades i redundància. Per tant, aquest projecte proposa un enfocament per analitzar un procés des de la perspectiva FDI i per tal d'implementar-ho proporciona l'eina FAST la qual cobreix des de la fase d'anàlisi i disseny fins a la implementació final d'un supervisor FDI en un procés real. Per sintetitzar la informació del procés s'ha definit un format simple basat en XML. Aquest format proporciona la informació necessària per realitzar de forma sistemàtica l'Anàlisi Estructural del procés. Qualsevol procés pot ser analitzat, només hi ha la restricció de que els models dels components han d'estar disponibles en l'eina FAST. Els processos es descriuen en termes de variables de procés, components i relacions i l'eina realitza l'anàlisi estructural obtenint: (i) la matriu estructural, (ii) el Perfect Matching, (iii) les relacions de redundància analítica, si n'hi ha, i (iv) la matriu signatura de fallades. Per ajudar durant el procés d'anàlisi, FAST pot operar aïlladament en mode de simulació permetent a l'enginyer de procés avaluar fallades, la seva detectabilitat i implementar canvis en els components del procés i la topologia per tal de millorar les capacitats de diagnosi i redundància. Per altra banda, FAST pot operar en línia connectat al procés de la planta per mitjà d'una interfície OPC. La interfície OPC permet la possibilitat de connectar gairebé a qualsevol procés que inclogui un sistema SCADA per la seva supervisió. Quan funciona en mode en línia, el procés està monitoritzat per un agent software anomenat l'Agent Supervisor. Addicionalment, FAST té la capacitat d'implementar FDI de forma distribuïda utilitzant la seva arquitectura multi-agent. L'eina permet dividir sistemes industrials complexes en subsistemes, identificar quines variables de procés han de ser compartides per cada subsistema i generar una instància d'Agent Supervisor per cadascun dels subsistemes identificats. Els Agents Supervisor un cop activats, començaran diagnosticant els components locals i despatxant les peticions de valors per les variables que FAST ha identificat com compartides amb altres agents, per tal d'implementar el procés FDI de forma distribuïda.Postprint (published version

    Developing a distributed electronic health-record store for India

    Get PDF
    The DIGHT project is addressing the problem of building a scalable and highly available information store for the Electronic Health Records (EHRs) of the over one billion citizens of India

    Wireless distributed intelligence in personal applications

    Get PDF
    Tietokoneet ovat historian kuluessa kehittyneet keskustietokoneista hajautettujen, langattomasti toimivien järjestelmien suuntaan. Elektroniikalla toteutetut automaattiset toiminnot ympärillämme lisääntyvät kiihtyvällä vauhdilla. Tällaiset sovellukset lisääntyvät tulevaisuudessa, mutta siihen soveltuva tekniikka on vielä kehityksen alla ja vaadittavia ominaisuuksia ei aina löydy. Nykyiset lyhyen kantaman langattoman tekniikan standardit ovat tarkoitettu lähinnä teollisuuden ja multimedian käyttöön, siksi ne ovat vain osittain soveltuvia uudenlaisiin ympäristöälykkäisiin käyttötarkoituksiin. Ympäristöälykkäät sovellukset palvelevat enimmäkseen jokapäiväistä elämäämme, kuten turvallisuutta, kulunvalvontaa ja elämyspalveluita. Ympäristöälykkäitä ratkaisuja tarvitaan myös hajautetussa automaatiossa ja kohteiden automaattisessa seurannassa. Tutkimuksen aikana Seinäjoen ammattikorkeakoulussa on tutkittu lyhyen kantaman langatonta tekniikkaa: suunniteltu ja kehitetty pienivirtaisia radionappeja, niitten ohjelmointiympäristöä sekä langattoman verkon synkronointia, tiedonkeruuta ja reititystä. Lisäksi on simuloitu eri reititystapoja, sisäpaikannusta ja kaivinkoneen kalibrointia soveltaen mm. neurolaskentaa. Tekniikkaa on testattu myös käytännön sovelluksissa. Ympäristöälykkäät sovellusalueet ovat ehkä nopeimmin kasvava lähitulevaisuuden ala tietotekniikassa. Tutkitulla tekniikalla on runsaasti uusia haasteita ihmisten hyvinvointia, terveyttä ja turvallisuutta lisäävissä sovelluksissa, kuten myös teollisuuden uusissa sovelluksissa, esimerkiksi älykkäässä energiansiirtoverkossa.The development of computing is moving from mainframe computers to distributed intelligence with wireless features. The automated functions around us, in the form of small electronic devices, are increasing and the pace is continuously accelerating. The number of these applications will increase in the future, but suitable features needed are lacking and suitable technology development is still ongoing. The existing wireless short-range standards are mostly suitable for use in industry and in multimedia applications, but they are only partly suitable for the new network feature demands of the ambient intelligence applications. The ambient intelligent applications will serve us in our daily lives: security, access control and exercise services. Ambient intelligence is also adopted by industry in distributed amorphous automation, in access monitoring and the control of machines and devices. During this research, at Seinäjoki University of Applied Sciences, we have researched, designed and developed short-range wireless technology: low-power radio buttons with a programming environment for them as well as synchronization, data collecting and routing features for the wireless network. We have simulated different routing methods, indoor positioning and excavator calibration using for example neurocomputing. In addition, we have tested the technology in practical applications. The ambient intelligent applications are perhaps the area growing the most in information technology in the future. There will be many new challenges to face to increase welfare, health, security, as well as industrial applications (for example, at factories and in smart grids) in the future.fi=vertaisarvioitu|en=peerReviewed
    corecore