59 research outputs found

    Reduced cognitive deficits after FLASH irradiation of whole mouse brain are associated with less hippocampal dendritic spine loss and neuroinflammation

    Get PDF
    Aim To evaluate the impact of ultra-rapid FLASH mouse whole brain irradiation on hippocampal dendritic spines and neuroinflammation, factors associated with cognitive impairment after brain irradiation. Methods We administered 30 Gy whole brain irradiation to C57BL6/J mice in sub-second (FLASH) vs. 240 s conventional delivery time keeping all other parameters constant, using a custom configured clinical linac. Ten weeks post-irradiation, we evaluated spatial and non-spatial object recognition using novel object location and object recognition testing. We measured dendritic spine density by tracing Golgi-stained hippocampal neurons and evaluated neuroinflammation by CD68 immunostaining, a marker of activated microglia, and expression of 10 pro-inflammatory cytokines using a multiplex immunoassay. Results At ten weeks post-irradiation, compared to unirradiated controls, conventional delivery time irradiation significantly impaired novel object location and recognition tasks whereas the same dose given in FLASH delivery did not. Conventional delivery time, but not FLASH, was associated with significant loss of dendritic spine density in hippocampal apical dendrites, with a similar non-significant trend in basal dendrites. Conventional delivery time was associated with significantly increased CD68-positive microglia compared to controls whereas FLASH was not. Conventional delivery time was associated with significant increases in 5 of 10 pro-inflammatory cytokines in the hippocampus (and non-significant increases in another 3), whereas FLASH was associated with smaller increases in only 3. Conclusion Reduced cognitive impairment and associated neurodegeneration were observed with FLASH compared to conventional delivery time irradiation, potentially through decreased induction of neuroinflammation, suggesting a promising approach to increasing therapeutic index in radiation therapy of brain tumors

    Measurement of the F2 structure function in deep inelastic e+^{+}p scattering using 1994 data from the ZEUS detector at HERA

    Get PDF
    We present measurements of the structure function \Ft\ in e^+p scattering at HERA in the range 3.5\;\Gevsq < \qsd < 5000\;\Gevsq. A new reconstruction method has allowed a significant improvement in the resolution of the kinematic variables and an extension of the kinematic region covered by the experiment. At \qsd < 35 \;\Gevsq the range in x now spans 6.3\cdot 10^{-5} < x < 0.08 providing overlap with measurements from fixed target experiments. At values of Q^2 above 1000 GeV^2 the x range extends to 0.5. Systematic errors below 5\perc\ have been achieved for most of the kinematic urray, W

    Observation of Events with an Energetic Forward Neutron in Deep Inelastic Scattering at HERA

    Get PDF
    In deep inelastic neutral current scattering of positrons and protons at the center of mass energy of 300 GeV, we observe, with the ZEUS detector, events with a high energy neutron produced at very small scattering angles with respect to the proton direction. The events constitute a fixed fraction of the deep inelastic, neutral current event sample independent of Bjorken x and Q2 in the range 3 · 10-4 \u3c xBJ \u3c 6 · 10-3 and 10 \u3c Q2 \u3c 100 GeV2

    Measurement of Elastic ϕ\phi Photoproduction at HERA

    Full text link
    The production of ϕ\phi mesons in the reaction e+pe+ϕpe^{+}p \rightarrow e^{+} \phi p (ϕK+K\phi \rightarrow K^{+}K^{-}) at a median Q2Q^{2} of $10^{-4} \ \rm{GeV^2}hasbeenstudiedwiththeZEUSdetectoratHERA.Thedifferential has been studied with the ZEUS detector at HERA. The differential \phiphotoproductioncrosssection photoproduction cross section d\sigma/dthasanexponentialshapeandhasbeendeterminedinthekinematicrange has an exponential shape and has been determined in the kinematic range 0.1<|t|<0.5 \ \rm{GeV^2}and and 60 < W < 80 \ \rm{GeV}.Anintegratedcrosssectionof. An integrated cross section of \sigma_{\gamma p \rightarrow \phi p} = 0.96 \pm 0.19^{+0.21}_{-0.18} \rm{\mu b}hasbeenobtainedbyextrapolatingtot=0.Whencomparedtolowerenergydata,theresultsshowaweakenergydependenceofboth has been obtained by extrapolating to {\it t} = 0. When compared to lower energy data, the results show a weak energy dependence of both \sigma_{\gamma p \rightarrow \phi p}andtheslopeofthe and the slope of the tdistribution.The distribution. The \phidecayangulardistributionsareconsistentwith decay angular distributions are consistent with schannelhelicityconservation.FromlowerenergiestoHERAenergies,thefeaturesof-channel helicity conservation. From lower energies to HERA energies, the features of \phi$ photoproduction are compatible with those of a soft diffractive process.Comment: 23 pages, including 6 post script figure

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals &lt;1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data
    corecore