59 research outputs found
Non-periodic liquid movement inside the glass nozzle during air bubbles departures in water
Paper presented at the 9th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Malta, 16-18 July, 2012.In the paper the dynamics of liquid movement inside the glass nozzle submerged in the glass tank filled by distilled water has been analyzed. Considered liquid movement accompanied the process of bubble departures from the nozzle. There has been investigated the influence of air volume flow rate on the dynamics of liquid movement. The position of liquid-air interface inside the glass nozzle has been measured using the high speed camera. Recorded videos have been analyzed using the special software allowing to obtain the time series of position of air-liquid interface inside the glass nozzle. The dynamics of such obtained time series has been analyzed using the non-linear methods. The attractor reconstruction, correlation dimension and reoccurrence plot have been applied.dc201
Double diffractive cross-section measurement in the forward region at LHC
The first double diffractive cross-section measurement in the very forward
region has been carried out by the TOTEM experiment at the LHC with
center-of-mass energy of sqrt(s)=7 TeV. By utilizing the very forward TOTEM
tracking detectors T1 and T2, which extend up to |eta|=6.5, a clean sample of
double diffractive pp events was extracted. From these events, we measured the
cross-section sigma_DD =(116 +- 25) mub for events where both diffractive
systems have 4.7 <|eta|_min < 6.5 .Comment: 5 pages, 1 figure, submitted for publicatio
LHC Optics Measurement with Proton Tracks Detected by the Roman Pots of the TOTEM Experiment
Precise knowledge of the beam optics at the LHC is crucial to fulfil the
physics goals of the TOTEM experiment, where the kinematics of the scattered
protons is reconstructed with the near-beam telescopes -- so-called Roman Pots
(RP). Before being detected, the protons' trajectories are influenced by the
magnetic fields of the accelerator lattice. Thus precise understanding of the
proton transport is of key importance for the experiment. A novel method of
optics evaluation is proposed which exploits kinematical distributions of
elastically scattered protons observed in the RPs. Theoretical predictions, as
well as Monte Carlo studies, show that the residual uncertainty of this optics
estimation method is smaller than 0.25 percent.Comment: 20 pages, 11 figures, 5 figures, to be submitted to New J. Phy
Diamond Detectors for the TOTEM Timing Upgrade
This paper describes the design and the performance of the timing detector
developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the
Time-Of-Flight (TOF) of the protons produced in central diffractive
interactions at the LHC. The measurement of the TOF of the protons allows the
determination of the longitudinal position of the proton interaction vertex and
its association with one of the vertices reconstructed by the CMS detectors.
The TOF detector is based on single crystal Chemical Vapor Deposition (scCVD)
diamond plates and is designed to measure the protons TOF with about 50 ps time
precision. This upgrade to the TOTEM apparatus will be used in the LHC run 2
and will tag the central diffractive events up to an interaction pileup of
about 1. A dedicated fast and low noise electronics for the signal
amplification has been developed. The digitization of the diamond signal is
performed by sampling the waveform. After introducing the physics studies that
will most profit from the addition of these new detectors, we discuss in detail
the optimization and the performance of the first TOF detector installed in the
LHC in November 2015.Comment: 26 pages, 18 figures, 2 tables, submitted for publication to JINS
Performance of the TOTEM Detectors at the LHC
The TOTEM Experiment is designed to measure the total proton-proton
cross-section with the luminosity-independent method and to study elastic and
diffractive pp scattering at the LHC. To achieve optimum forward coverage for
charged particles emitted by the pp collisions in the interaction point IP5,
two tracking telescopes, T1 and T2, are installed on each side of the IP in the
pseudorapidity region 3.1 < = |eta | < = 6.5, and special movable beam-pipe
insertions - called Roman Pots (RP) - are placed at distances of +- 147 m and
+- 220 m from IP5. This article describes in detail the working of the TOTEM
detector to produce physics results in the first three years of operation and
data taking at the LHC.Comment: 40 pages, 31 figures, submitted to Int. J. Mod. Phys.
Evidence for non-exponential elastic proton-proton differential cross-section at low |t| and sqrt(s) = 8 TeV by TOTEM
The TOTEM experiment has made a precise measurement of the elastic
proton-proton differential cross-section at the centre-of-mass energy sqrt(s) =
8 TeV based on a high-statistics data sample obtained with the beta* = 90
optics. Both the statistical and systematic uncertainties remain below 1%,
except for the t-independent contribution from the overall normalisation. This
unprecedented precision allows to exclude a purely exponential differential
cross-section in the range of four-momentum transfer squared 0.027 < |t| < 0.2
GeV^2 with a significance greater than 7 sigma. Two extended parametrisations,
with quadratic and cubic polynomials in the exponent, are shown to be well
compatible with the data. Using them for the differential cross-section
extrapolation to t = 0, and further applying the optical theorem, yields total
cross-section estimates of (101.5 +- 2.1) mb and (101.9 +- 2.1) mb,
respectively, in agreement with previous TOTEM measurements.Comment: Final version published in Nuclear Physics
Observation of proton-tagged, central (semi)exclusive production of high-mass lepton pairs in pp collisions at 13 TeV with the CMS-TOTEM precision proton spectrometer
The process pp -> pl(+)l(-)p(()*()), with l(+)l(-) a muon or an electron pair produced at midrapidity with mass larger than 110 GeV, has been observed for the first time at the LHC in pp collisions at root s = 13 TeV. One of the two scattered protons is measured in the CMS-TOTEM precision proton spectrometer (CT-PPS), which operated for the first time in 2016. The second proton either remains intact or is excited and then dissociates into a low-mass state p*, which is undetected. The measurement is based on an integrated luminosity of 9.4 fb(-1) collected during standard, high-luminosity LHC operation. A total of 12 mu(+)/mu(-) and 8 e(+)e(-) pairs with m(l(+)l(-)) > 110 GeV, and matching forward proton kinematics, are observed, with expected backgrounds of 1.49 +/- 0.07 (stat) +/- 0.53 (syst) and 2.36 +/- 0.09 (stat) +/- 0.47(syst), respectively. This corresponds to an excess of more than five standard deviations over the expected background. The present result constitutes the first observation of proton-tagged gamma gamma collisions at the electroweak scale. This measurement also demonstrates that CT-PPS performs according to the design specifications.Peer reviewe
- …