14 research outputs found

    Determination of the nature of the Cu coordination complexes formed in the presence of NO and NH3 within SSZ-13

    Get PDF
    Ammonia-selective catalytic reduction (NH3-SCR) using Cu zeolites is a well-established strategy for the abatement of NOx gases. Recent studies have demonstrated that Cu is particularly active when exchanged into the SSZ-13 zeolite, and its location in either the 6r or 8r renders it an excellent model system for fundamental studies. In this work, we examine the interaction of NH3-SCR relevant gases (NO and NH3) with the Cu2+ centers within the SSZ-13 structure, coupling powder diffraction (PD), X-ray absorption spectroscopy (XAFS), and density functional theory (DFT). This combined approach revealed that, upon calcination, cooling and gas exposure Cu ions tend to locate in the 8r window. After NO introduction, Cu-ions are seen to coordinate to two framework oxygens and one NO molecule, resulting in a bent Cu-nitrosyl complex with a Cu-N-O bond angle of similar to 150 degrees. Whilst Cu seems to be partially reduced/changed in coordination state, NO is partially oxidized. On exposure to NH3 while the PD data suggest the Cu2+ ion occupies a similar position, simulation and XAFS pointed toward the formation of a Jahn-Teller distorted hexaamine complex [Cu(NH3)(6)](2+) in the center of the cha cage. These results have important implications in terms of uptake and storage of these reactive gases and potentially for the mechanisms involved in the NH3-SCR process

    Structural and magnetic characterization of the elusive Jahn-Teller active NaCrF3

    Get PDF
    We report the structural and magnetic characterization of the elusive Jahn- Teller active compound NaCrF3

    In situ solid-state NMR and XRD studies of the ADOR process and the unusual structure of zeolite IPC-6

    Get PDF
    R.E.M. and M.N. thank the Royal Society and the E.P.S.R.C. (Grants EP/L014475/1, EP/K025112/1 and EP/K005499/1) for funding work in this area. R.E.M. and J.Č. acknowledge the Czech Science Foundation for the project P106/12/G015 and OP VVV "Excellent Research Teams", project No. CZ.02.1.01/0.0/0.0/15_003/0000417 - CUCAM. S.E.A. would like to thank the ERC (EU FP7 Consolidator Grant 614290 “EXONMR”) and the Royal Society and Wolfson Foundation for a merit award. The UK 850 MHz solid-state NMR Facility used in this research was funded by EPSRC and BBSRC (contract reference PR140003), as well as the University of Warwick including via part funding through Birmingham Science City Advanced Materials Projects 1 and 2 supported by Advantage West Midlands (AWM) and the European Regional Development Fund (ERDF). W.A.S. and D.S.W. acknowledge the Research Council of Norway and NOTUR are acknowledged for providing the computer time at the Norwegian supercomputer facilities (under the project number NN2875k).The assembly–disassembly–organization–reassembly (ADOR) mechanism is a recent method for preparing inorganic framework materials and, in particular, zeolites. This flexible approach has enabled the synthesis of isoreticular families of zeolites with unprecedented continuous control over porosity, and the design and preparation of materials that would have been difficult—or even impossible—to obtain using traditional hydrothermal techniques. Applying the ADOR process to a parent zeolite with the UTL framework topology, for example, has led to six previously unknown zeolites (named IPC-n, where n = 2, 4, 6, 7, 9 and 10). To realize the full potential of the ADOR method, however, a further understanding of the complex mechanism at play is needed. Here, we probe the disassembly, organization and reassembly steps of the ADOR process through a combination of in situ solid-state NMR spectroscopy and powder X-ray diffraction experiments. We further use the insight gained to explain the formation of the unusual structure of zeolite IPC-6.PostprintPeer reviewe

    Local order in high-entropy alloys and associated deuterides - a total scattering and Reverse Monte Carlo study

    Get PDF
    Many of the materials properties of high-entropy alloys (HEAs), like increased hardness, reduced thermal and electrical conductivity, and interesting hydrogen storage properties, are proposed to be related to local lattice distortions of the crystal structure due to the significant size differences between the elements of the alloy. However, direct evidence of this effect is very limited in the literature, and it therefore remains a hypothesis. This work presents a detailed assessment of the local lattice distortion in three body-centered cubic (bcc) HEAs TiVNb, TiVZrNb and TiVZrNbHf with varying atomic size differences using total scattering measurements and Reverse Monte Carlo structure modelling. The analysis indicates that the amount of local lattice distortion in the alloys increases with the elemental size difference in the alloy. The amount of lattice distortion is relieved when dideuterides with CaF2-type structures (Fm (3) over barm) are formed from the bcc (Im (3) over barm) HEAs. Analyses of the local environments around the deuterium atoms reveal an interesting correlation between the valence-electron concentration (VEC) of the nearest-neighbour metals and the stability of tetrahedral interstices with respect to deuterium occupation. Moreover, there is a tendency towards Ti/Nb short-range order in TiVNbD5.7 where the mixing entropy is lowest. In TiVZrNbHfD10, about 6 % of the deuterium atoms are displaced from the tetrahedral interstices with smaller volumes to octahedral interstices

    Determination of the Nature of the Cu Coordination Complexes Formed in the Presence of NO and NH<sub>3</sub> within SSZ-13

    No full text
    Ammonia-selective catalytic reduction (NH<sub>3</sub>-SCR) using Cu zeolites is a well-established strategy for the abatement of NO<sub><i>x</i></sub> gases. Recent studies have demonstrated that Cu is particularly active when exchanged into the SSZ-13 zeolite, and its location in either the <i>6r</i> or <i>8r</i> renders it an excellent model system for fundamental studies. In this work, we examine the interaction of NH<sub>3</sub>-SCR relevant gases (NO and NH<sub>3</sub>) with the Cu<sup>2+</sup> centers within the SSZ-13 structure, coupling powder diffraction (PD), X-ray absorption spectroscopy (XAFS), and density functional theory (DFT). This combined approach revealed that, upon calcination, cooling and gas exposure Cu ions tend to locate in the <i>8r</i> window. After NO introduction, Cu ions are seen to coordinate to two framework oxygens and one NO molecule, resulting in a bent Cu–nitrosyl complex with a Cu–N–O bond angle of ∌150°. Whilst Cu seems to be partially reduced/changed in coordination state, NO is partially oxidized. On exposure to NH<sub>3</sub> while the PD data suggest the Cu<sup>2+</sup> ion occupies a similar position, simulation and XAFS pointed toward the formation of a Jahn–Teller distorted hexaamine complex [Cu­(NH<sub>3</sub>)<sub>6</sub>]<sup>2+</sup> in the center of the <i>cha</i> cage. These results have important implications in terms of uptake and storage of these reactive gases and potentially for the mechanisms involved in the NH<sub>3</sub>-SCR process

    Patients with Crohn's disease have longer post-operative in-hospital stay than patients with colon cancer but no difference in complications' rate

    Get PDF
    BACKGROUNDRight hemicolectomy or ileocecal resection are used to treat benign conditions like Crohn's disease (CD) and malignant ones like colon cancer (CC).AIMTo investigate differences in pre- and peri-operative factors and their impact on post-operative outcome in patients with CC and CD.METHODSThis is a sub-group analysis of the European Society of Coloproctology's prospective, multi-centre snapshot audit. Adult patients with CC and CD undergoing right hemicolectomy or ileocecal resection were included. Primary outcome measure was 30-d post-operative complications. Secondary outcome measures were post-operative length of stay (LOS) at and readmission.RESULTSThree hundred and seventy-five patients with CD and 2,515 patients with CC were included. Patients with CD were younger (median = 37 years for CD and 71 years for CC (P &lt; 0.01), had lower American Society of Anesthesiology score (ASA) grade (P &lt; 0.01) and less comorbidity (P &lt; 0.01), but were more likely to be current smokers (P &lt; 0.01). Patients with CD were more frequently operated on by colorectal surgeons (P &lt; 0.01) and frequently underwent ileocecal resection (P &lt; 0.01) with higher rate of de-functioning/primary stoma construction (P &lt; 0.01). Thirty-day post-operative mortality occurred exclusively in the CC group (66/2515, 2.3%). In multivariate analyses, the risk of post-operative complications was similar in the two groups (OR 0.80, 95%CI: 0.54-1.17; P = 0.25). Patients with CD had a significantly longer LOS (Geometric mean 0.87, 95%CI: 0.79-0.95; P &lt; 0.01). There was no difference in re-admission rates. The audit did not collect data on post-operative enhanced recovery protocols that are implemented in the different participating centers.CONCLUSIONPatients with CD were younger, with lower ASA grade, less comorbidity, operated on by experienced surgeons and underwent less radical resection but had a longer LOS than patients with CC although complication's rate was not different between the two groups

    The impact of stapling technique and surgeon specialism on anastomotic failure after right?sided colorectal resection: an international multicentre, prospective audit

    Get PDF
    Aim There is little evidence to support choice of technique and configuration for stapled anastomoses after right hemicolectomy and ileocaecal resection. This study aimed to determine the relationship between stapling technique and anastomotic failure. Method Any unit performing gastrointestinal surgery was invited to contribute data on consecutive adult patients undergoing right hemicolectomy or ileocolic resection to this prospective, observational, international, multicentre study. Patients undergoing stapled, side?to?side ileocolic anastomoses were identified and multilevel, multivariable logistic regression analyses were performed to explore factors associated with anastomotic leak. Results One thousand three hundred and forty?seven patients were included from 200 centres in 32 countries. The overall anastomotic leak rate was 8.3%. Upon multivariate analysis there was no difference in leak rate with use of a cutting stapler for apical closure compared with a noncutting stapler (8.4% vs 8.0%, OR 0.91, 95% CI 0.54–1.53, P = 0.72). Oversewing of the apical staple line, whether in the cutting group (7.9% vs 9.7%, OR 0.87, 95% CI 0.52–1.46, P = 0.60) or noncutting group (8.9% vs 5.7%, OR 1.40, 95% CI 0.46–4.23, P = 0.55) also conferred no benefit in terms of reducing leak rates. Surgeons reporting to be general surgeons had a significantly higher leak rate than those reporting to be colorectal surgeons (12.1% vs 7.3%, OR 1.65, 95% CI 1.04–2.64, P = 0.04). Conclusion This study did not identify any difference in anastomotic leak rates according to the type of stapling device used to close the apical aspect. In addition, oversewing of the anastomotic staple lines appears to confer no benefit in terms of reducing leak rates. Although general surgeons operated on patients with more high?risk characteristics than colorectal surgeons, a higher leak rate for general surgeons which remained after risk adjustment needs further exploration

    Predictors for anastomotic leak, postoperative complications, and mortality after right colectomy for cancer: Results from an international snapshot audit

    No full text
    Background: A right hemicolectomy is among the most commonly performed operations for colon cancer, but modern high-quality, multination data addressing the morbidity and mortality rates are lacking. Objective: This study reports the morbidity and mortality rates for right-sided colon cancer and identifies predictors for unfavorable short-term outcome after right hemicolectomy. Design: This was a snapshot observational prospective study. Setting: The study was conducted as a multicenter international study. Patients: The 2015 European Society of Coloproctology snapshot study was a prospective multicenter international series that included all patients undergoing elective or emergency right hemicolectomy or ileocecal resection over a 2-month period in early 2015. This is a subanalysis of the colon cancer cohort of patients. Main Outcome Measures: Predictors for anastomotic leak and 30-day postoperative morbidity and mortality were assessed using multivariable mixed-effect logistic regression models after variables selection with the Lasso method. Results: Of the 2515 included patients, an anastomosis was performed in 97.2% (n = 2444), handsewn in 38.5% (n = 940) and stapled in 61.5% (n = 1504) cases. The overall anastomotic leak rate was 7.4% (180/2444), 30-day morbidity was 38.0% (n = 956), and mortality was 2.6% (n = 66). Patients with anastomotic leak had a significantly increased mortality rate (10.6% vs 1.6% no-leak patients; p 65 0.001). At multivariable analysis the following variables were associated with anastomotic leak: longer duration of surgery (OR = 1.007 per min; p = 0.0037), open approach (OR = 1.9; p = 0.0037), and stapled anastomosis (OR = 1.5; p = 0.041). Limitations: This is an observational study, and therefore selection bias could be present. For this reason, a multivariable logistic regression model was performed, trying to correct possible confounding factors. Conclusions: Anastomotic leak after oncologic right hemicolectomy is a frequent complication, and it is associated with increased mortality. The key contributing surgical factors for anastomotic leak were anastomotic technique, surgical approach, and duration of surgery
    corecore