104 research outputs found

    Breaking down the delta wing vortex: The role of vorticity in the breakdown process

    Get PDF
    Experimental x-wire measurements of the flowfield above a 70 and 75 deg flat plate delta wing were performed at a Reynolds number of 250,000. Grids were taken normal to the wing at various chordwise locations for angles of attack of 20 and 30 deg. Axial and azimuthal vorticity distributions were derived from the velocity fields. The dependence of circulation on distance from the vortex core and on chordwise location was also examined. The effects of nondimensionalization in comparison with other experimental data is made. The results indicate that the circulation distribution scales with the local semispan and grows in a nearly linear fashion in the chordwise direction. The spanwise distribution of axial vorticity is severely altered through the breakdown. The axial vorticity components with a negative sense, such as that found in the secondary vortex, seem to remain unaffected by changes in wind sweep or angle of attack, in direct contrast to the positive components. In addition, the inclusion of the local wing geometry into a previously derived correlation parameter allows the circulation of growing leading edge vortex flows to be reduced into a single curve

    An experimental analysis of critical factors involved in the breakdown process of leading edge vortex flows

    Get PDF
    Experimental crosswire measurements of the flowfield above a 70 and 75 degree flat plate delta wing were performed at a Reynolds number of 250,000. Survey grids were taken normal to the platform at a series of chordwise locations for angles of attack of 20 and 30 degrees. Axial and azimuthal vorticity distributions were derived from the velocity fields. The dependence of circulation on distance from the vortex core as well as on chordwise location was examined. The effects of nondimensionalization in comparison with other experimental data was made. The circulation distribution scales with the local semispan and grows approximately linearly in the chordwise direction. For regions of the flow outside of the vortex subcore, the circulation at any chordwise station was observed to vary logarithmically with distance from the vortex axis. The circulation was also found to increase linearly with angle of incidence at a given chordwise station. A reduction in the local circulation about the vortex axis occurred at breakdown. The spanwise distribution of axial vorticity was severely altered through the breakdown region and the spanwise distribution of axial vorticity present appeared to reach a maximum immediately preceding breakdown. The local concentration of axial vorticity about the vortex axis was reduced while the magnitude of the azimuthal vorticity decreased throughout the breakdown zone. The axial vorticity components with a negative sense, found in the secondary vortex, remained unaffected by changes in wing sweep or angle of attack, in direct contrast to the positive components. The inclusion of the local wing geometry into a previously derived correlation parameter indicated that the circulation of growing leading edge vortex flows were similar at corresponding radii from the vortex axis. It was concluded that the flow over a delta wing, upstream of the breakdown regions and away from the apex and trailing edge regions, is conical. In addition, the dominating factors leading to the onset of breakdown are felt to be the local circulation of the vortex and the accompanying pressure field

    Aerodynamic Comparison of Hyper-Elliptic Cambered Span (HECS) Wings with Conventional Configurations

    Get PDF
    An experimental study was conducted to examine the aerodynamic and flow field characteristics of hyper-elliptic cambered span (HECS) wings and compare results with more conventional configurations used for induced drag reduction. Previous preliminary studies, indicating improved L/D characteristics when compared to an elliptical planform prompted this more detailed experimental investigation. Balance data were acquired on a series of swept and un-swept HECS wings, a baseline elliptic planform, two winglet designs and a raked tip configuration. Seven-hole probe wake surveys were also conducted downstream of a number of the configurations. Wind tunnel results indicated aerodynamic performance levels of all but one of the HECS wings exceeded that of the other configurations. The flow field data surveys indicate the HECS configurations displaced the tip vortex farther outboard of the wing than the Baseline configuration. Minimum drag was observed on the raked tip configuration and it was noted that the winglet wake lacked the cohesive vortex structure present in the wakes of the other configurations

    International Guillain-Barré Syndrome Outcome Study (IGOS): protocol of a prospective observational cohort study on clinical and biological predictors of disease course and outcome in Guillain-Barré syndrome

    Get PDF
    Guillain-Barré syndrome (GBS) is an acute polyradiculoneuropathy with a highly variable clinical presentation, course, and outcome. The factors that determine the clinical variation of GBS are poorly understood which complicates the care and treatment of individual patients. The protocol of the ongoing International GBS Outcome Study (IGOS), a prospective, observational, multi-centre cohort study that aims to identify the clinical and biological determinants and predictors of disease onset, subtype, course and outcome of GBS is presented here. Patients fulfilling the diagnostic criteria for GBS, regardless of age, disease severity, variant forms, or treatment, can participate if included within two weeks after onset of weakness. Information about demography, preceding infections, clinical features, diagnostic findings, treatment, course and outcome is collected. In addition, cerebrospinal fluid and serial blood samples for serum and DNA is collected at standard time points. The original aim was to include at least 1000 patients with a follow-up of 1-3 years. Data are collected via a web-based data entry system and stored anonymously. IGOS started in May 2012 and by January 2017 included more than 1400 participants from 143 active centres in 19 countries across 5 continents. The IGOS data/biobank is available for research projects conducted by expertise groups focusing on specific topics including epidemiology, diagnostic criteria, clinimetrics, electrophysiology, antecedent events, antibodies, genetics, prognostic modelling, treatment effects and long-term outcome of GBS. The IGOS will help to standardize the international collection of data and biosamples for future research of GBS. ClinicalTrials.gov Identifier: NCT01582763

    Age-based disparities in end-of-life decisions in Belgium: a population-based death certificate survey

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A growing body of scientific research is suggesting that end-of-life care and decision making may differ between age groups and that elderly patients may be the most vulnerable to exclusion of due care at the end of life. This study investigates age-related disparities in the rate of end-of-life decisions with a possible or certain life shortening effect (ELDs) and in the preceding decision making process in Flanders, Belgium in 2007, where euthanasia was legalised in 2002. Comparing with data from an identical survey in 1998 we also study the plausibility of the ‘slippery slope’ hypothesis which predicts a rise in the rate of administration of life ending drugs without patient request, especially among elderly patients, in countries where euthanasia is legal.</p> <p>Method</p> <p>We performed a post-mortem survey among physicians certifying a large representative sample (n = 6927) of death certificates in 2007, identical to a 1998 survey. Response rate was 58.4%.</p> <p>Results</p> <p>While the rates of non-treatment decisions (NTD) and administration of life ending drugs without explicit request (LAWER) did not differ between age groups, the use of intensified alleviation of pain and symptoms (APS) and euthanasia/assisted suicide (EAS), as well as the proportion of euthanasia requests granted, was bivariately and negatively associated with patient age. Multivariate analysis showed no significant effects of age on ELD rates. Older patients were less often included in decision making for APS and more often deemed lacking in capacity than were younger patients. Comparison with 1998 showed a decrease in the rate of LAWER in all age groups except in the 80+ age group where the rate was stagnant.</p> <p>Conclusion</p> <p>Age is not a determining factor in the rate of end-of-life decisions, but is in decision making as patient inclusion rates decrease with old age. Our results suggest there is a need to focus advance care planning initiatives on elderly patients. The slippery slope hypothesis cannot be confirmed either in general or among older people, as since the euthanasia law fewer LAWER cases were found.</p

    Penumbral imaging and functional outcome in patients with anterior circulation ischaemic stroke treated with endovascular thrombectomy versus medical therapy: a meta-analysis of individual patient-level data

    Get PDF
    Background: CT perfusion (CTP) and diffusion or perfusion MRI might assist patient selection for endovascular thrombectomy. We aimed to establish whether imaging assessments of irreversibly injured ischaemic core and potentially salvageable penumbra volumes were associated with functional outcome and whether they interacted with the treatment effect of endovascular thrombectomy on functional outcome. Methods: In this systematic review and meta-analysis, the HERMES collaboration pooled patient-level data from all randomised controlled trials that compared endovascular thrombectomy (predominantly using stent retrievers) with standard medical therapy in patients with anterior circulation ischaemic stroke, published in PubMed from Jan 1, 2010, to May 31, 2017. The primary endpoint was functional outcome, assessed by the modified Rankin Scale (mRS) at 90 days after stroke. Ischaemic core was estimated, before treatment with either endovascular thrombectomy or standard medical therapy, by CTP as relative cerebral blood flow less than 30% of normal brain blood flow or by MRI as an apparent diffusion coefficient less than 620 ÎŒm2/s. Critically hypoperfused tissue was estimated as the volume of tissue with a CTP time to maximum longer than 6 s. Mismatch volume (ie, the estimated penumbral volume) was calculated as critically hypoperfused tissue volume minus ischaemic core volume. The association of ischaemic core and penumbral volumes with 90-day mRS score was analysed with multivariable logistic regression (functional independence, defined as mRS score 0–2) and ordinal logistic regression (functional improvement by at least one mRS category) in all patients and in a subset of those with more than 50% endovascular reperfusion, adjusted for baseline prognostic variables. The meta-analysis was prospectively designed by the HERMES executive committee, but not registered. Findings: We identified seven studies with 1764 patients, all of which were included in the meta-analysis. CTP was available and assessable for 591 (34%) patients and diffusion MRI for 309 (18%) patients. Functional independence was worse in patients who had CTP versus those who had diffusion MRI, after adjustment for ischaemic core volume (odds ratio [OR] 0·47 [95% CI 0·30–0·72], p=0·0007), so the imaging modalities were not pooled. Increasing ischaemic core volume was associated with reduced likelihood of functional independence (CTP OR 0·77 [0·69–0·86] per 10 mL, pinteraction=0·29; diffusion MRI OR 0·87 [0·81–0·94] per 10 mL, pinteraction=0·94). Mismatch volume, examined only in the CTP group because of the small numbers of patients who had perfusion MRI, was not associated with either functional independence or functional improvement. In patients with CTP with more than 50% endovascular reperfusion (n=186), age, ischaemic core volume, and imaging-to-reperfusion time were independently associated with functional improvement. Risk of bias between studies was generally low. Interpretation: Estimated ischaemic core volume was independently associated with functional independence and functional improvement but did not modify the treatment benefit of endovascular thrombectomy over standard medical therapy for improved functional outcome. Combining ischaemic core volume with age and expected imaging-to-reperfusion time will improve assessment of prognosis and might inform endovascular thrombectomy treatment decisions. Funding: Medtronic

    EULAR recommendations for the management of rheumatoid arthritis with synthetic and biological disease-modifying antirheumatic drugs: 2016 update

    Get PDF
    Recent insights in rheumatoid arthritis (RA) necessitated updating the European League Against Rheumatism (EULAR) RA management recommendations. A large international Task Force based decisions on evidence from 3 systematic literature reviews, developing 4 overarching principles and 12 recommendations (vs 3 and 14, respectively, in 2013). The recommendations address conventional synthetic (cs) disease-modifying antirheumatic drugs (DMARDs) (methotrexate (MTX), leflunomide, sulfasalazine); glucocorticoids (GC); biological (b) DMARDs (tumour necrosis factor (TNF)-inhibitors (adalimumab, certolizumab pegol, etanercept, golimumab, infliximab), abatacept, rituximab, tocilizumab, clazakizumab, sarilumab and sirukumab and biosimilar (bs) DMARDs) and targeted synthetic (ts) DMARDs (Janus kinase (Jak) inhibitors tofacitinib, baricitinib). Monotherapy, combination therapy, treatment strategies (treat-to-target) and the targets of sustained clinical remission (as defined by the American College of Rheumatology-(ACR)-EULAR Boolean or index criteria) or low disease activity are discussed. Cost aspects were taken into consideration. As first strategy, the Task Force recommends MTX (rapid escalation to 25 mg/week) plus short-term GC, aiming at >50% improvement within 3 and target attainment within 6 months. If this fails stratification is recommended. Without unfavourable prognostic markers, switching to—or adding—another csDMARDs (plus short-term GC) is suggested. In the presence of unfavourable prognostic markers (autoantibodies, high disease activity, early erosions, failure of 2 csDMARDs), any bDMARD (current practice) or Jak-inhibitor should be added to the csDMARD. If this fails, any other bDMARD or tsDMARD is recommended. If a patient is in sustained remission, bDMARDs can be tapered. For each recommendation, levels of evidence and Task Force agreement are provided, both mostly very high. These recommendations intend informing rheumatologists, patients, national rheumatology societies, hospital officials, social security agencies and regulators about EULAR's most recent consensus on the management of RA, aimed at attaining best outcomes with current therapies

    Design, Performance, and Calibration of CMS Hadron-Barrel Calorimeter Wedges

    Get PDF
    Extensive measurements have been made with pions, electrons and muons on four production wedges of the Compact Muon Solenoid (CMS) hadron barrel (HB) calorimeter in the H2 beam line at CERN with particle momenta varying from 20 to 300 GeV/c. Data were taken both with and without a prototype electromagnetic lead tungstate crystal calorimeter (EB) in front of the hadron calorimeter. The time structure of the events was measured with the full chain of preproduction front-end electronics running at 34 MHz. Moving-wire radioactive source data were also collected for all scintillator layers in the HB. These measurements set the absolute calibration of the HB prior to first pp collisions to approximately 4%

    Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    Get PDF
    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are in agreement. Above 30 GeV, LHEP gives a more accurate simulation of the longitudinal shower profile
    • 

    corecore