26 research outputs found

    Comparative study on sound production in different Holocentridae species

    Get PDF
    <p/> <p>Background</p> <p>Holocentrids (squirrelfish and soldierfish) are vocal reef fishes whose calls and sound-producing mechanisms have been studied in some species only. The present study aims to compare sound-producing mechanisms in different Holocentridae genera (<it>Holocentrus</it>, <it>Myripristis</it>, <it>Neoniphon</it>, <it>Sargocentron</it>) from separate regions and, in some cases, at different developmental stages. An accurate comparison was made by recording six species while being hand-held, by observing TEM) the sonic muscles and by dissections of the sound-producing mechanism.</p> <p>Results</p> <p>In all these species, calls presented harmonics, their dominant frequency was between 80 and 130 Hz and they were composed of trains of 4 to 11 pulses with gradual increasing periods towards the end of the call. In each case, the calls did not provide reliable information on fish size. The sounds were produced by homologous fast-contracting sonic muscles that insert on articulated ribs whose proximal heads are integrated into the swimbladder: each pulse is the result of the back and forth movements of the ribs. Small differences in the shape of the oscillograms of the different species could be related to the number of ribs that are involved in the sound-producing mechanism. These fish species are able to make sounds as soon as they settle on the reef, when they are 40 days old. Comparison between <it>Neoniphon </it>from Madagascar and from Rangiroa in French Polynesia showed a new, unexpected kind of dialect involving differences at the level of pulse distribution. <it>Neoniphon </it>calls were characterised by a single pulse that was isolated at the beginning of the remaining train in Madagascar whereas they did not show any isolated single pulses at the beginning of the call in Rangiroa.</p> <p>Conclusion</p> <p>This family cannot use the acoustic fundamental frequencies (or pulse periods) of grunts to infer the size of partners. Pulse duration and number of pulses are statistically related to fish size. However, these characteristics are poorly informative because the correlation slope values are weak. It remains other features (sound amplitude, resistance to muscle fatigue, calling frequency) could be used to assess the body size. Characteristics of the sound producing mechanisms are conservative. All species possess fast-contracting muscles and have the same kind of sound producing mechanism. They do show some change between clades but these differences are not important enough to deeply modify the waveforms of the calls. In this case, our description of the grunt could be considered as the signature for the holocentrid family and can be used in passive acoustic monitoring.</p

    New Normative Database of Inner Macular Layer Thickness Measured by Spectralis OCT Used as Reference Standard for Glaucoma Detection

    Get PDF
    Purpose: This study examines the capacity to detect glaucoma of inner macular layer thickness measured by spectral-domain optical coherence tomography (SD-OCT) using a new normative database as the reference standard. Methods: Participants (N = 148) were recruited from Leuven (Belgium) and Zaragoza (Spain): 74 patients with early/moderate glaucoma and 74 age-matched healthy controls. One eye was randomly selected for a macular scan using the Spectralis SD-OCT. The variables measured with the instrument's segmentation software were: macular nerve fiber layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) volume and thickness along with circumpapillary RNFL thickness (cpRNFL). The new normative database of macular variables was used to define the cutoff of normality as the fifth percentile by age group. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) of each macular measurement and of cpRNFL were used to distinguish between patients and controls. Results: Overall sensitivity and specificity to detect early-moderate glaucoma were 42.2% and 88.9% for mRNFL, 42.4% and 95.6% for GCL, 42.2% and 94.5% for IPL, and 53% and 94.6% for RNFL, respectively. The best macular variable to discriminate between the two groups of subjects was outer temporal GCL thickness as indicated by an AUROC of 0.903. This variable performed similarly to mean cpRNFL thickness (AUROC = 0.845; P = 0.29). Conclusions: Using our normative database as reference, the diagnostic power of inner macular layer thickness proved comparable to that of peripapillary RNFL thickness. Translational Relevance: Spectralis SD-OCT, cpRNFL thickness, and individual macular inner layer thicknesses show comparable diagnostic capacity for glaucoma and RNFL, GCL, and IPL thickness may be useful as an alternative diagnostic test when the measure of cpRNFL shows artifacts

    Genome-Wide Association Analysis of Autoantibody Positivity in Type 1 Diabetes Cases

    Get PDF
    The genetic basis of autoantibody production is largely unknown outside of associations located in the major histocompatibility complex (MHC) human leukocyte antigen (HLA) region. The aim of this study is the discovery of new genetic associations with autoantibody positivity using genome-wide association scan single nucleotide polymorphism (SNP) data in type 1 diabetes (T1D) patients with autoantibody measurements. We measured two anti-islet autoantibodies, glutamate decarboxylase (GADA, n = 2,506), insulinoma-associated antigen 2 (IA-2A, n = 2,498), antibodies to the autoimmune thyroid (Graves') disease (AITD) autoantigen thyroid peroxidase (TPOA, n = 8,300), and antibodies against gastric parietal cells (PCA, n = 4,328) that are associated with autoimmune gastritis. Two loci passed a stringent genome-wide significance level (p<10(-10)): 1q23/FCRL3 with IA-2A and 9q34/ABO with PCA. Eleven of 52 non-MHC T1D loci showed evidence of association with at least one autoantibody at a false discovery rate of 16%: 16p11/IL27-IA-2A, 2q24/IFIH1-IA-2A and PCA, 2q32/STAT4-TPOA, 10p15/IL2RA-GADA, 6q15/BACH2-TPOA, 21q22/UBASH3A-TPOA, 1p13/PTPN22-TPOA, 2q33/CTLA4-TPOA, 4q27/IL2/TPOA, 15q14/RASGRP1/TPOA, and 12q24/SH2B3-GADA and TPOA. Analysis of the TPOA-associated loci in 2,477 cases with Graves' disease identified two new AITD loci (BACH2 and UBASH3A)

    Biodiversity post-2020: Closing the gap between global targets and national-level implementation

    Get PDF
    National and local governments need to step up efforts to effectively implement the post-2020 global biodiversity framework of the Convention on Biological Diversity to halt and reverse worsening biodiversity trends. Drawing on recent advances in interdisciplinary biodiversity science, we propose a framework for improved implementation by national and subnational governments. First, the identification of actions and the promotion of ownership across stakeholders need to recognize the multiple values of biodiversity and account for remote responsibility. Second, cross-sectorial implementation and mainstreaming should adopt scalable and multifunctional ecosystem restoration approaches and target positive futures for nature and people. Third, assessment of progress and adaptive management can be informed by novel biodiversity monitoring and modeling approaches handling the multidimensionality of biodiversity change

    What is bad in cancer is good in the embryo: Importance of EMT in neural crest development

    Full text link

    Functional neuroimaging of the reciprocal influences between sleep and wakefulness.

    Full text link
    The activity patterns adopted by brain neuronal populations differ dramatically between wakefulness and sleep. However, these vigilance states are not independent and they reciprocally interact. Here, we provide evidence that in humans, regional brain activity during wakefulness is influenced by sleep regulation, namely by the interaction between sleep homeostasis and circadian signals. We also show that, by contrast, regional brain activity during sleep is influenced by the experience acquired during the preceding waking period. These data reveal the dynamic interactions by which the succession of vigilance states support normal brain function and human cognition

    Target-Specific Effects of Deep Brain Stimulation for Tourette Syndrome: A Systematic Review and Meta-Analysis

    No full text
    Background: Extended research has pointed to the efficacy of deep brain stimulation (DBS) in treatment of patients with treatment-refractory Tourette syndrome (TS). The four most commonly used DBS targets for TS include the centromedian nucleus-nucleus ventrooralis internus (CM-Voi) and the centromedian nucleus-parafascicular (CM-Pf) complexes of the thalamus, and the posteroventrolateral (pvIGPi) and the anteromedial portion of the globus pallidus internus (amGPi). Differences and commonalities between those targets need to be compared systematically. Objective: Therefore, we evaluated whether DBS is effective in reducing TS symptoms and target-specific differences. Methods: A PubMed literature search was conducted according to the PRISMA guidelines. Eligible literature was used to conduct a systematic review and meta-analysis. Results: In total, 65 studies with 376 patients were included. Overall, Yale Global Tic Severity Scale (YGTSS) scores were reduced by more than 50 in 69% of the patients. DBS also resulted in significant reductions of secondary outcome measures, including the total YGTSS, modified Rush Video-Based Tic Rating Scale (mRVRS), Yale-Brown Obsessive Compulsive Scale (YBOCS), and Becks Depression Inventory (BDI). All targets resulted in significant reductions of YGTSS scores and, with the exception of the CM-Pf, also in reduced YBOCS scores. Interestingly, DBS of pallidal targets showed increased YGTSS and YBOCS reductions compared to thalamic targets. Also, the meta-analysis including six randomized controlled and double-blinded trials demonstrated clinical efficacy of DBS for TS, that remained significant for GPi but not thalamic stimulation in two separate meta-analyses. Conclusion: We conclude that DBS is a clinically effective treatment option for patients with treatment-refractory TS, with all targets showing comparable improvement rates. Future research might focus on personalized and symptom-specific target selection.</p

    New Normative Database of Inner Macular Layer Thickness Measured by Spectralis OCT Used as Reference Standard for Glaucoma Detection

    No full text
    Purpose: This study examines the capacity to detect glaucoma of inner macular layer thickness measured by spectral-domain optical coherence tomography (SD-OCT) using a new normative database as the reference standard. Methods: Participants (N = 148) were recruited from Leuven (Belgium) and Zaragoza (Spain): 74 patients with early/moderate glaucoma and 74 age-matched healthy controls. One eye was randomly selected for a macular scan using the Spectralis SD-OCT. The variables measured with the instrument's segmentation software were: macular nerve fiber layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) volume and thickness along with circumpapillary RNFL thickness (cpRNFL). The new normative database of macular variables was used to define the cutoff of normality as the fifth percentile by age group. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) of each macular measurement and of cpRNFL were used to distinguish between patients and controls. Results: Overall sensitivity and specificity to detect early-moderate glaucoma were 42.2% and 88.9% for mRNFL, 42.4% and 95.6% for GCL, 42.2% and 94.5% for IPL, and 53% and 94.6% for RNFL, respectively. The best macular variable to discriminate between the two groups of subjects was outer temporal GCL thickness as indicated by an AUROC of 0.903. This variable performed similarly to mean cpRNFL thickness (AUROC = 0.845; P = 0.29). Conclusions: Using our normative database as reference, the diagnostic power of inner macular layer thickness proved comparable to that of peripapillary RNFL thickness. Translational Relevance: Spectralis SD-OCT, cpRNFL thickness, and individual macular inner layer thicknesses show comparable diagnostic capacity for glaucoma and RNFL, GCL, and IPL thickness may be useful as an alternative diagnostic test when the measure of cpRNFL shows artifacts.status: publishe
    corecore