93 research outputs found

    Iodine intakes and status in Irish adults is there cause for concern?

    Get PDF
    I is an important mineral for health, required for the production of key thyroid hormones, which are essential for cellular metabolism, growth and physical development. Hence, adequate I is crucial at all stages of life, but imperative during pregnancy for fetal brain development and during a child’s early life for neurodevelopment. Within Ireland, limited information exists on population I intakes and status. Therefore, the purposes of the present analysis were to estimate dietary I intakes and to analyse urinary iodine (UI) status using the cross-sectional National Adult Nutrition Survey 2008–2010 and the most recent Irish Total Diet Study. Median I intakes in the total population (n 1106) were adequate with only 26 % of the population being classified as below the estimated average requirement (EAR). Milk consumption was the major source of I in the diet, contributing 45 % to total intake. Likewise, median UI concentrations (107 ”g/l) indicated ‘optimal’ I nutrition according to the WHO cut-off points. In our cohort, 77 % of women of childbearing age (18–50 years) did not meet the EAR recommendation set for pregnant women. Although I is deemed to be sufficient in the majority of adult populations resident in Ireland, any changes to the current dairy practices could significantly impact intake and status. Continued monitoring should be of priority to ensure that all subgroups of the population are I sufficient

    Precision scans of the pixel cell response of double sided 3D pixel detectors to pion and x-ray beams

    Get PDF
    hree-dimensional (3D) silicon sensors offer potential advantages over standard planar sensors for radiation hardness in future high energy physics experiments and reduced charge-sharing for X-ray applications, but may introduce inefficiencies due to the columnar electrodes. These inefficiencies are probed by studying variations in response across a unit pixel cell in a 55Όm pitch double-sided 3D pixel sensor bump bonded to TimePix and Medipix2 readout ASICs. Two complementary characterisation techniques are discussed: the first uses a custom built telescope and a 120GeV pion beam from the Super Proton Synchrotron (SPS) at CERN; the second employs a novel technique to illuminate the sensor with a micro-focused synchrotron X-ray beam at the Diamond Light Source, UK. For a pion beam incident perpendicular to the sensor plane an overall pixel efficiency of 93.0±0.5% is measured. After a 10o rotation of the device the effect of the columnar region becomes negligible and the overall efficiency rises to 99.8±0.5%. The double-sided 3D sensor shows significantly reduced charge sharing to neighbouring pixels compared to the planar device. The charge sharing results obtained from the X-ray beam study of the 3D sensor are shown to agree with a simple simulation in which charge diffusion is neglected. The devices tested are found to be compatible with having a region in which no charge is collected centred on the electrode columns and of radius 7.6±0.6Όm. Charge collection above and below the columnar electrodes in the double-sided 3D sensor is observed

    The UA9 experimental layout

    Full text link
    The UA9 experimental equipment was installed in the CERN-SPS in March '09 with the aim of investigating crystal assisted collimation in coasting mode. Its basic layout comprises silicon bent crystals acting as primary collimators mounted inside two vacuum vessels. A movable 60 cm long block of tungsten located downstream at about 90 degrees phase advance intercepts the deflected beam. Scintillators, Gas Electron Multiplier chambers and other beam loss monitors measure nuclear loss rates induced by the interaction of the beam halo in the crystal. Roman pots are installed in the path of the deflected particles and are equipped with a Medipix detector to reconstruct the transverse distribution of the impinging beam. Finally UA9 takes advantage of an LHC-collimator prototype installed close to the Roman pot to help in setting the beam conditions and to analyze the efficiency to deflect the beam. This paper describes in details the hardware installed to study the crystal collimation during 2010.Comment: 15pages, 11 figure, submitted to JINS

    Ni-62(n,gamma) and Ni-63(n,gamma) cross sections measured at the n_TOF facility at CERN

    Get PDF
    The cross section of the Ni-62(n,gamma) reaction was measured with the time-of-flight technique at the neutron time-of-flight facility n_TOF at CERN. Capture kernels of 42 resonances were analyzed up to 200 keV neutron energy and Maxwellian averaged cross sections (MACS) from kT = 5-100 keV were calculated. With a total uncertainty of 4.5%, the stellar cross section is in excellent agreement with the the KADoNiS compilation at kT = 30 keV, while being systematically lower up to a factor of 1.6 at higher stellar temperatures. The cross section of the Ni-63(n,gamma) reaction was measured for the first time at n_TOF. We determined unresolved cross sections from 10 to 270 keV with a systematic uncertainty of 17%. These results provide fundamental constraints on s-process production of heavier species, especially the production of Cu in massive stars, which serve as the dominant source of Cu in the solar system.Peer reviewedFinal Accepted Versio

    Review of hybrid pixel detector readout ASICs for spectroscopic X-ray imaging

    Get PDF
    Semiconductor detector readout chips with pulse processing electronics have made possible spectroscopic X-ray imaging, bringing an improvement in the overall image quality and, in the case of medical imaging, a reduction in the X-ray dose delivered to the patient. In this contribution we review the state of the art in semiconductor-detector readout ASICs for spectroscopic X-ray imaging with emphasis on hybrid pixel detector technology. We discuss how some of the key challenges of the technology (such as dealing with high fluxes, maintaining spectral fidelity, power consumption density) are addressed by the various ASICs. In order to understand the fundamental limits of the technology, the physics of the interaction of radiation with the semiconductor detector and the process of signal induction in the input electrodes of the readout circuit are described. Simulations of the process of signal induction are presented that reveal the importance of making use of the small pixel effect to minimize the impact of the slow motion of holes and hole trapping in the induced signal in high-Z sensor materials. This can contribute to preserve fidelity in the measured spectrum with relatively short values of the shaper peaking time. Simulations also show, on the other hand, the distortion in the energy spectrum due to charge sharing and fluorescence photons when the pixel pitch is decreased. However, using recent measurements from the Medipix3 ASIC, we demonstrate that the spectroscopic information contained in the incoming photon beam can be recovered by the implementation in hardware of an algorithm whereby the signal from a single photon is reconstructed and allocated to the pixel with the largest deposition

    Comparative results on collimation of the SPS beam of protons and Pb ions with bent crystals

    Get PDF
    New experiments on crystal assisted collimation have been carried out at the CERN SPS with stored beams of 120 GeV/. c protons and Pb ions. Bent silicon crystals of 2 mm long with about 170 ÎŒrad bend angle and a small residual torsion were used as primary collimators. In channeling conditions, the beam loss rate induced by inelastic interactions of particles with the crystal nuclei is minimal. The loss reduction was about 6 for protons and about 3 for Pb ions. Lower reduction value for Pb ions can be explained by their considerably larger ionization losses in the crystal. In one of the crystals, the measured fraction of the Pb ion beam halo deflected in channeling conditions was 74%, a value very close to that for protons. The intensity of the off-momentum halo leaking out from the collimation station was measured in the first high dispersion area downstream. The particle population in the shadow of the secondary collimator-absorber was considerably smaller in channeling conditions than for amorphous orientations of the crystal. The corresponding reduction was in the range of 2-5 for both protons and Pb ions.peer-reviewe

    Observation of parametric X-rays produced by 400 GeV/c protons in bent crystals

    Get PDF
    Spectral maxima of parametric X-ray radiation (PXR) produced by 400 GeV/c protons in bent silicon crystals aligned with the beam have been observed in an experiment at the H8 external beam of the CERN SPS. The total yield of PXR photons was about 10-6 per proton. Agreement between calculations and the experimental data shows that the PXR kinematic theory is valid for bent crystals with sufficiently small curvature as used in the experiment. The intensity of PXR emitted from halo protons in a bent crystal used as a primary collimator in a circular accelerator may be considered as a possible tool to control its crystal structure, which is slowly damaged because of irradiation. The intensity distribution of PXR peaks depends on the crystal thickness intersected by the beam, which changes for different orientations of a crystal collimator. This dependence may be used to control crystal collimator alignment by analyzing PXR spectra produced by halo protons.peer-reviewe

    Effect of Cadmium in Wood Ash on Spring Wheat Vitality: pot experiment

    No full text
    The reutilization of residues derived from the bio-energy processes in agriculture is important for more effective nutrient cycle in ecosystem. This study evaluated wood fly ash (WFA) as an agricultural soil supplement. Spring wheat was grown on two different soils amended with different ash rates. The aim of our study was to investigate long-term effects of Cd contained in WFA on spring wheat vitality and yield during 3 years of cumulative ash application. Cd concentration in samples was analysed by inductively coupled plasma optical emission spectrometer (ICP-OES). WFA addition significantly decreased (p < 0.05) total Cd content in spring wheat, especially in the second experimental year and with increased WFA rate, probably because of increased soil pH and ash sorption ability caused by the ash addition. Grain yield was affected by the addition of ash at lower doses where we observed almost 100 % yield increase compared to untreated control and wheat straw showed the highest yields at the most ash enriched treatments growing in the last year. The risk of Cd contamination appears to be low, even from the long-term view and hence there are justifiable grounds for applying wood ash to the soil

    Medipix Imaging - evaluation of datasets with PCA

    Get PDF
    Spectral datasets of a watch and a fetal hand have been acquired with the energy-resolving 2D X-ray imaging detector Medipix-2. We applied principal component analysis (PCA) to evaluate the spectral information in the data. PCA is useful as it identifies the relevant information in a few derived variables that account for most of the variance of the dataset. A scattergram and cluster analysis allow us to group pixels with similar spectral characteristics. With our data, three derived variables display the most relevant information of the full dataset which can be represented in one RGB image. We have begun to apply this method to CT reconstructed slices to separate different materials. Our approach applies PCA to the energy domain and should not be confused with widely used applications of PCA in pattern recognition where it is applied to the spatial domain
    • 

    corecore