518 research outputs found

    真实性抑或现实性:有关历史剧讨论的讨论

    Get PDF
    Studies have been performed on the radiation hardness of the type of VCSELs**2 Vertical Cavity Surface Emitting Lasers. that will be used in the ATLAS SemicConductor Tracker. The measurements were made using 30 MeV proton beams, 24 GeV/c proton beams and a gamma source. The lifetime of the devices after irradiation was studied

    Anti-Angiogenic Activity of a Small Molecule STAT3 Inhibitor LLL12

    Get PDF
    Background: Recent data indicate the Signal Transducer and Activator of Transcription 3 (STAT3) pathway is required for VEGF production and angiogenesis in various types of cancers. STAT3 inhibitors have been shown to reduce tumor microvessel density in tumors but a direct anti-angiogenic activity has not been described. Methodology/Principal Findings: We investigated the direct action of a small molecule inhibitor of STAT3 (LLL12) in human umbilical cord vascular endothelial cells (HUVECs) in vitro, in a Matrigel model for angiogenesis in vivo, and its antitumor activity in a xenograft model of osteosarcoma. LLL12 (100 nM) significantly inhibited VEGF-stimulated STAT3 phosphorylation in HUVECs, reduced their proliferation/migration and inhibited VEGF-induced tube formation. Morphologic analysis of LLL12 treated HUVECs demonstrated marked changes in actin/tubulin distribution and bundling. In scid mice, LLL12 reduced microvessel invasion into VEGF-infused Matrigel plugs by,90 % at a dose of 5 mg/kg daily. Following a period of tumor progression (2 weeks), LLL12 completely suppressed further growth of established OS-1 osteosarcoma xenografts. Pharmacodynamic studies showed robust phosphorylated STAT3 in control tumors, whereas phospho-STAT3 was not detected in LLL12-treated OS-1 tumors. Treated tumors demonstrated decreased proliferation (Ki67 staining), and decreased microvessel density (CD34 staining), but no significant increase in apoptosis (TUNEL staining), relative to controls. Assay of angiogenic factors, using an antibody array, showed VEGF, MMP-9, Angiopoietin1/2, Tissue Factor and FGF-

    Measurement of CP-violation asymmetries in D0 to Ks pi+ pi-

    Get PDF
    We report a measurement of time-integrated CP-violation asymmetries in the resonant substructure of the three-body decay D0 to Ks pi+ pi- using CDF II data corresponding to 6.0 invfb of integrated luminosity from Tevatron ppbar collisions at sqrt(s) = 1.96 TeV. The charm mesons used in this analysis come from D*+(2010) to D0 pi+ and D*-(2010) to D0bar pi-, where the production flavor of the charm meson is determined by the charge of the accompanying pion. We apply a Dalitz-amplitude analysis for the description of the dynamic decay structure and use two complementary approaches, namely a full Dalitz-plot fit employing the isobar model for the contributing resonances and a model-independent bin-by-bin comparison of the D0 and D0bar Dalitz plots. We find no CP-violation effects and measure an asymmetry of ACP = (-0.05 +- 0.57 (stat) +- 0.54 (syst))% for the overall integrated CP-violation asymmetry, consistent with the standard model prediction.Comment: 15 page

    Discovery of Radio Emission from the Brown Dwarf LP944-20

    Get PDF
    Brown dwarfs are classified as objects which are not massive enough to sustain nuclear fusion of hydrogen, and are distinguished from planets by their ability to burn deuterium. Old (>10 Myr) brown dwarfs are expected to possess short-lived magnetic fields and, since they no longer generate energy from collapse and accretion, weak radio and X-ray emitting coronae. Several efforts have been undertaken in the past to detect chromospheric activity from the brown dwarf LP944-20 at X-ray and optical wavelengths, but only recently an X-ray flare from this object was detected. Here we report on the discovery of quiescent and flaring radio emission from this source, which represents the first detection of persistent radio emission from a brown dwarf, with luminosities that are several orders of magnitude larger than predicted from an empirical relation between the X-ray and radio luminosities of many stellar types. We show in the context of synchrotron emission, that LP944-20 possesses an unusually weak magnetic field in comparison to active dwarf M stars, which might explain the null results from previous optical and X-ray observations of this source, and the deviation from the empirical relations.Comment: Accepted to Natur

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Heterogeneous Response to a Quorum-Sensing Signal in the Luminescence of Individual Vibrio fischeri

    Get PDF
    The marine bacterium Vibrio fischeri regulates its bioluminescence through a quorum sensing mechanism: the bacterium releases diffusible small molecules (autoinducers) that accumulate in the environment as the population density increases. This accumulation of autoinducer (AI) eventually activates transcriptional regulators for bioluminescence as well as host colonization behaviors. Although V.fischeri quorum sensing has been extensively characterized in bulk populations, far less is known about how it performs at the level of the individual cell, where biochemical noise is likely to limit the precision of luminescence regulation. We have measured the time-dependence and AI-dependence of light production by individual V.fischeri cells that are immobilized in a perfusion chamber and supplied with a defined concentration of exogenous AI. We use low-light level microscopy to record and quantify the photon emission from the cells over periods of several hours as they respond to the introduction of AI. We observe an extremely heterogeneous response to the AI signal. Individual cells differ widely in the onset time for their luminescence and in their resulting brightness, even in the presence of high AI concentrations that saturate the light output from a bulk population. The observed heterogeneity shows that although a given concentration of quorum signal may determine the average light output from a population of cells, it provides far weaker control over the luminescence output of each individual cell
    corecore