22 research outputs found
Observation of the TeV gamma-ray source MGRO J1908+06 with ARGO-YBJ
The extended gamma ray source MGRO J1908+06, discovered by the Milagro air
shower detector in 2007, has been observed for about 4 years by the ARGO-YBJ
experiment at TeV energies, with a statistical significance of 6.2 standard
deviations. The peak of the signal is found at a position consistent with the
pulsar PSR J1907+0602. Parametrizing the source shape with a two-dimensional
Gauss function we estimate an extension \sigma = 0.49 \pm 0.22 degrees,
consistent with a previous measurement by the Cherenkov Array H.E.S.S.. The
observed energy spectrum is dN/dE = 6.1 \pm 1.4 \times 10^-13 (E/4 TeV)^{-2.54
\pm 0.36} photons cm^-2 s^-1 TeV^-1, in the energy range 1-20 TeV. The measured
gamma ray flux is consistent with the results of the Milagro detector, but is
2-3 times larger than the flux previously derived by H.E.S.S. at energies of a
few TeV. The continuity of the Milagro and ARGO-YBJ observations and the stable
excess rate observed by ARGO-YBJ along 4 years of data taking support the
identification of MGRO J1908+06 as the steady powerful TeV pulsar wind nebula
of PSR J1907+0602, with an integrated luminosity above 1 TeV about 1.8 times
the Crab Nebula luminosity.Comment: 6 pages, accepted for pubblication by ApJ. Replaced to correct the
author lis
Long-term Monitoring on Mrk 501 for Its VHE gamma Emission and a Flare in October 2011
As one of the brightest active blazars in both X-ray and very high energy
-ray bands, Mrk 501 is very useful for physics associated with jets
from AGNs. The ARGO-YBJ experiment is monitoring it for -rays above 0.3
TeV since November 2007. Starting from October 2011 the largest flare since
2005 is observed, which lasts to about April 2012. In this paper, a detailed
analysis is reported. During the brightest -rays flaring episodes from
October 17 to November 22, 2011, an excess of the event rate over 6 is
detected by ARGO-YBJ in the direction of Mrk 501, corresponding to an increase
of the -ray flux above 1 TeV by a factor of 6.62.2 from its steady
emission. In particular, the -ray flux above 8 TeV is detected with a
significance better than 4 . Based on time-dependent synchrotron
self-Compton (SSC) processes, the broad-band energy spectrum is interpreted as
the emission from an electron energy distribution parameterized with a single
power-law function with an exponential cutoff at its high energy end. The
average spectral energy distribution for the steady emission is well described
by this simple one-zone SSC model. However, the detection of -rays
above 8 TeV during the flare challenges this model due to the hardness of the
spectra. Correlations between X-rays and -rays are also investigated.Comment: have been accepted for publication at Ap
Mortality and pulmonary complications in patients undergoing surgery with perioperative SARS-CoV-2 infection: an international cohort study
Background: The impact of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) on postoperative recovery needs to be understood to inform clinical decision making during and after the COVID-19 pandemic. This study reports 30-day mortality and pulmonary complication rates in patients with perioperative SARS-CoV-2 infection. Methods: This international, multicentre, cohort study at 235 hospitals in 24 countries included all patients undergoing surgery who had SARS-CoV-2 infection confirmed within 7 days before or 30 days after surgery. The primary outcome measure was 30-day postoperative mortality and was assessed in all enrolled patients. The main secondary outcome measure was pulmonary complications, defined as pneumonia, acute respiratory distress syndrome, or unexpected postoperative ventilation. Findings: This analysis includes 1128 patients who had surgery between Jan 1 and March 31, 2020, of whom 835 (74·0%) had emergency surgery and 280 (24·8%) had elective surgery. SARS-CoV-2 infection was confirmed preoperatively in 294 (26·1%) patients. 30-day mortality was 23·8% (268 of 1128). Pulmonary complications occurred in 577 (51·2%) of 1128 patients; 30-day mortality in these patients was 38·0% (219 of 577), accounting for 81·7% (219 of 268) of all deaths. In adjusted analyses, 30-day mortality was associated with male sex (odds ratio 1·75 [95% CI 1·28–2·40], p\textless0·0001), age 70 years or older versus younger than 70 years (2·30 [1·65–3·22], p\textless0·0001), American Society of Anesthesiologists grades 3–5 versus grades 1–2 (2·35 [1·57–3·53], p\textless0·0001), malignant versus benign or obstetric diagnosis (1·55 [1·01–2·39], p=0·046), emergency versus elective surgery (1·67 [1·06–2·63], p=0·026), and major versus minor surgery (1·52 [1·01–2·31], p=0·047). Interpretation: Postoperative pulmonary complications occur in half of patients with perioperative SARS-CoV-2 infection and are associated with high mortality. Thresholds for surgery during the COVID-19 pandemic should be higher than during normal practice, particularly in men aged 70 years and older. Consideration should be given for postponing non-urgent procedures and promoting non-operative treatment to delay or avoid the need for surgery. Funding: National Institute for Health Research (NIHR), Association of Coloproctology of Great Britain and Ireland, Bowel and Cancer Research, Bowel Disease Research Foundation, Association of Upper Gastrointestinal Surgeons, British Association of Surgical Oncology, British Gynaecological Cancer Society, European Society of Coloproctology, NIHR Academy, Sarcoma UK, Vascular Society for Great Britain and Ireland, and Yorkshire Cancer Research
A new look at Goldstone's theorem
SIGLEAvailable from TIB Hannover: RA 2999(92-057) / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekDEGerman
Towards a determination of g_8 and g_2_7 from twisted mass lattice QCD
A first step towards solving the #DELTA#I=1/2 puzzle consists in a determination of the lowest order coupling constants g_8 and g_2_7 in the effective chiral theory. This could be achieved by matching to lattice results for unphysical K #-># #pi# transitions, provided light meson masses can be reached at reasonable computational costs. Using the framework of twisted mass QCD with an active charm quark, we show that the renormalization of K#-># #pi# matrix elements requires at most the subtraction of a linear divergence. In the (partially) quenched approximation one may eliminate the linear divergence by a suitable choice of the twist angles and the interpolating meson fields. (orig.)Available from TIB Hannover: RA 2999(03-131) / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekSIGLEDEGerman