387 research outputs found

    The H1 Forward Proton Spectrometer at HERA

    Full text link
    The forward proton spectrometer is part of the H1 detector at the HERA collider. Protons with energies above 500 GeV and polar angles below 1 mrad can be detected by this spectrometer. The main detector components are scintillating fiber detectors read out by position-sensitive photo-multipliers. These detectors are housed in so-called Roman Pots which allow them to be moved close to the circulating proton beam. Four Roman Pot stations are located at distances between 60 m and 90 m from the interaction point.Comment: 20 pages, 10 figures, submitted to Nucl.Instr.and Method

    Inclusive V0V^0 Production Cross Sections from 920 GeV Fixed Target Proton-Nucleus Collisions

    Full text link
    Inclusive differential cross sections dσpA/dxFd\sigma_{pA}/dx_F and dσpA/dpt2d\sigma_{pA}/dp_t^2 for the production of \kzeros, \lambdazero, and \antilambda particles are measured at HERA in proton-induced reactions on C, Al, Ti, and W targets. The incident beam energy is 920 GeV, corresponding to s=41.6\sqrt {s} = 41.6 GeV in the proton-nucleon system. The ratios of differential cross sections \rklpa and \rllpa are measured to be 6.2±0.56.2\pm 0.5 and 0.66±0.070.66\pm 0.07, respectively, for \xf 0.06\approx-0.06. No significant dependence upon the target material is observed. Within errors, the slopes of the transverse momentum distributions dσpA/dpt2d\sigma_{pA}/dp_t^2 also show no significant dependence upon the target material. The dependence of the extrapolated total cross sections σpA\sigma_{pA} on the atomic mass AA of the target material is discussed, and the deduced cross sections per nucleon σpN\sigma_{pN} are compared with results obtained at other energies.Comment: 17 pages, 7 figures, 5 table

    Periferne osteoporotske frakture osim kuka - epidemiologija i značenje

    Get PDF
    Fractures are the most serious consequence of osteoporosis. Non-vertebral and non-hip fractures are seldom recognised as important, even though they account for the majority of all fractures. The most prevalent localisations are distal radius, proximal humerus, ribs, clavicle, and the pelvis. According to the results from large phase III clinical trials for placebo groups, their incidence ranges from 4.9 % to 12.0 %. Hospital morbidity data in Croatia in 2006 show that peripheral non-hip fractures ranked among the leading fifteen injuries, accounting for 23.7 % of all injuries in patients aged 60 years and above. Risk factors for non-hip and non-vertebral fractures are similar to other osteoporotic fractures, and the main are low bone mineral density and earlier fractures. Quality of life is considerably affected by these fractures, and medical costs are very high, soaring as high as 36.9 % of all national medical costs in the USA. Nonvertebral non-hip fractures need more attention, which was also recognised by the European regulatory bodies that approve use of anti-osteoporotic drugs.Prijelomi su najozbiljnija posljedica osteoporoze. Iako čine većinu svih fraktura, nevertebralne frakture osim kuka rijetko se prepoznaju kao značajne. Najčešće lokalizacije tih prijeloma su: distalni dio radijusa, proksimalni dio humerusa, rebra, klavikula i zdjelica. Prema rezultatima iz placebo-grupa III. faze velikih kliničkih ispitivanja raspon njihove incidencije iznosi između 4,9 % i 12,0 %. Prema podacima bolničkog pobolijevanja za 2006. g. u Hrvatskoj, među 15 vodećih ozljeda u dobnoj grupi 60 i više godina 23,7 % bile su periferne frakture osim kuka. Čimbenici rizika za nevertebralne frakture osim onih kuka slični su kao i za druge osteoporotske frakture gdje središnje mjesto imaju niska mineralna gustoća kosti i prethodne frakture. Ove frakture imaju velik utjecaj na kvalitetu `ivota, a njihovi su troškovi vrlo visoki, tako da u SAD-u iznose čak 36.9 % svih nacionalnih medicinskih troškova. Nevertebralne frakture osim kuka zahtijevaju veću pozornost, što su i prepoznala europska regulatorna tijela koja odobravaju upotrebu antiosteoporotskih lijekova

    Capture the fracture: a best practice framework and global campaign to break the fragility fracture cycle

    Get PDF
    Summary The International Osteoporosis Foundation (IOF) Capture the Fracture Campaign aims to support implementation of Fracture Liaison Services (FLS) throughout the world. Introduction FLS have been shown to close the ubiquitous secondary fracture prevention care gap, ensuring that fragility fracture sufferers receive appropriate assessment and intervention to reduce future fracture risk. Methods Capture the Fracture has developed internationally endorsed standards for best practice, will facilitate change at the national level to drive adoption of FLS and increase awareness of the challenges and opportunities presented by secondary fracture prevention to key stakeholders. The Best Practice Framework (BPF) sets an international benchmark for FLS, which defines essential and aspirational elements of service delivery. Results The BPF has been reviewed by leading experts from many countries and subject to beta-testing to ensure that it is internationally relevant and fit-for-purpose. The BPF will also serve as a measurement tool for IOF to award ‘Capture the Fracture Best Practice Recognition’ to celebrate successful FLS worldwide and drive service development in areas of unmet need. The Capture the Fracture website will provide a suite of resources related to FLS and secondary fracture prevention, which will be updated as new materials become available. A mentoring programme will enable those in the early stages of development of FLS to learn from colleagues elsewhere that have achieved Best Practice Recognition. A grant programme is in development to aid clinical systems which require financial assistance to establish FLS in their localities. Conclusion Nearly half a billion people will reach retirement age during the next 20 years. IOF has developed Capture the Fracture because this is the single most important thing that can be done to directly improve patient care, of both women and men, and reduce the spiralling fracture-related care costs worldwide.</p

    Low bone mass in microscopic colitis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Microscopic colitis presents with similar symptoms to classic inflammatory bowel diseases. Osteoporosis is a common complication of Crohn's disease but there are no data concerning bone metabolism in microscopic colitis.</p> <p>Aims</p> <p>The aim of the present study was to evaluate bone density and metabolism in patients with microscopic colitis.</p> <p>Methods</p> <p>Fourteen patients microscopic colitis were included in the study, and 28 healthy persons and 28 age and gender matched Crohn's disease patients were enrolled as controls. Bone mineral density was measured using dual x-ray absorptiometry at the lumbar spine, femoral neck and the radius. Serum bone formation and bone resorption markers (osteocalcin and beta-crosslaps, respectively) were measured using immunoassays.</p> <p>Results</p> <p>Low bone mass was measured in 57.14% patients with microscopic colitis. Bone mineral density at the femoral neck in patients suffering from microscopic colitis and Crohn's disease was lower than in healthy controls (0.852 ± 0.165 and 0.807 ± 0.136 vs. 1.056 ± 0.126 g/cm<sup>2</sup>; p < 0.01). Bone mineral density at the non-dominant radius was decreased in microscopic colitis patients (0.565 ± 0.093 vs. 0.667 ± 0.072 g/cm<sup>2</sup>; p < 0.05) but unaffected in Crohn's disease patients (0.672 ± 0.056 g/cm<sup>2</sup>). Mean beta-crosslaps concentration was higher in microscopic colitis and Crohn's disease patients than controls (417.714 ± 250.37 and 466.071 ± 249.96 vs. 264.75 ± 138.65 pg/ml; p < 0.05). A negative correlation between beta-crosslaps concentration and the femoral and radius t-scores was evident in microscopic colitis patients.</p> <p>Conclusions</p> <p>Low bone mass is frequent in microscopic colitis, and alterations to bone metabolism are similar to those present in Crohn's disease. Therefore, microscopic colitis-associated osteopenia could be a significant problem in such patients.</p

    The QCD transition temperature: results with physical masses in the continuum limit II.

    Get PDF
    We extend our previous study [Phys. Lett. B643 (2006) 46] of the cross-over temperatures (T_c) of QCD. We improve our zero temperature analysis by using physical quark masses and finer lattices. In addition to the kaon decay constant used for scale setting we determine four quantities (masses of the \Omega baryon, K^*(892) and \phi(1020) mesons and the pion decay constant) which are found to agree with experiment. This implies that --independently of which of these quantities is used to set the overall scale-- the same results are obtained within a few percent. At finite temperature we use finer lattices down to a <= 0.1 fm (N_t=12 and N_t=16 at one point). Our new results confirm completely our previous findings. We compare the results with those of the 'hotQCD' collaboration.Comment: 19 pages, 8 figures, 3 table

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe
    corecore