1,204 research outputs found
Negative time delay for wave reflection from a one-dimensional semi-harmonic well
It is reported that the phase time of particles which are reflected by a
one-dimensional semi-harmonic well includes a time delay term which is negative
for definite intervals of the incoming energy. In this interval, the absolute
value of the negative time delay becomes larger as the incident energy becomes
smaller. The model is a rectangular well with zero potential energy at its
right and a harmonic-like interaction at its left.Comment: 6 pages, 5 eps figures. Talk presented at the XXX Workshop on
Geometric Methods in Physics, Bialowieza, Poland, 201
Which quality of life score is best for glaucoma patients and why?
<p>Abstract</p> <p>Background</p> <p>The glaucomas are generally asymptomatic diseases until they are very advanced. They affect 2% of the population over 40 years of age and therefore represent a significant public health issue. There have been a number of attempts to develop quality of life scales for the disease. This review discusses the pros and cons of these scales and suggests the best of the current ones for use in a clinical setting.</p> <p>Methods</p> <p>Medline, Embase and Google Scholar were searched for relevant articles. No time period was defined and all types of article were included.</p> <p>Results</p> <p>11 Quality of Life scores were identified that have been used with glaucoma patients.</p> <p>Conclusion</p> <p>There is no generally accepted 'best' Quality of Life instrument for use in glaucoma. Many of the scales are biased towards physical symptoms and do little to address the personal or social factors of the disease. Further work is needed to produce scales that address all these areas as well as being simple to administer in a clinical setting.</p
Amblyopia and quality of life: a systematic review
Background/Aims
Amblyopia is a common condition which can affect up to 5% of the general population. The health-related quality of life (HRQoL) implications of amblyopia and/or its treatment have been explored in the literature.
Methods
A systematic literature search was undertaken (16th-30th January 2007) to identify the HRQoL implications of amblyopia and/or its treatment.
Results
A total of 25 papers were included in the literature review. The HRQoL implications of amblyopia related specifically to amblyopia treatment, rather than the condition itself. These included the impact upon family life; social interactions; difficulties undertaking daily activities; and feelings and behaviour. The identified studies adopted a number of methodologies. The study populations included; children with the condition; parents of children with amblyopia; and adults who had undertaken amblyopia treatment as a child. Some studies developed their own measures of HRQoL, and others determined HRQoL through proxy measures.
Conclusions
The reported findings of the HRQoL implications are of importance when considering the management of cases of amblyopia. Further research is required to assess the immediate and long-term effects of amblyopia and/or its treatment upon HRQoL using a more standardised approach
Case-mix & patients' reports of outcome in Independent Sector Treatment Centres: Comparison with NHS providers
BACKGROUND: There has been considerable concern expressed about the outcomes achieved in Independent Sector Treatment Centres (ISTCs) introduced in England since 2003. Our aim was to compare the case-mix and patients' reported outcomes of surgery in ISTCs and in NHS providers. METHODS: Prospective cohort study of 769 patients treated in six ISTCs and 1895 treated in 20 NHS providers (acute hospitals and treatment centres) in England during 2006-07. Participants underwent one of three day surgery procedures (inguinal hernia repair, varicose vein surgery, cataract extraction) or hip or knee replacement. Change in patient-reported health status and health related quality of life (measured using a disease-specific and a generic (EQ-5D) instrument) was assessed either 3-months (day surgery) or 6-months (hip/knee) after surgery. In addition patient-reported post-operative complications and an overall assessment of success of surgery were collected. Outcome measures were adjusted (using multivariable regression) for patient characteristics (disease severity, duration of symptoms, age, sex, socioeconomic status, general health, previous similar surgery, comorbidity). RESULTS: Post-operative response rates varied by procedure (73%-88%) and were similar for those treated in ISTCs and NHS facilities. Patients treated in ISTCs were healthier, were less likely to have any comorbidity and, for those undergoing cataract surgery or joint replacement, their primary condition was less severe. Those undergoing hernia repair or joint replacement were less likely to have had similar surgery before. When adjustment was made for pre-operative characteristics, patients undergoing cataract surgery or hip replacement in ISTCs achieved a slightly greater improvement in functional status and quality of life than those treated in NHS facilities, while the opposite was true of patients undergoing hernia repair. No significant differences were found for the two other procedures. Patients treated in ISTCs were less likely to report post-operative problems than those treated in NHS facilities for cataract surgery (Adjusted Odds Ratio 0.35; 95% CI 0.17-0.70), hernia repair (0.42; 0.28-0.63) and knee replacement (0.44; 0.28-0.69). Most patients described the result of their operation as excellent, very good or good, regardless of where they were treated. CONCLUSION: The case-mix of patients treated in ISTCs differs from that in NHS providers, in line with the intention of the contracts. Caution is needed in interpreting the observation that patients treated in ISTCs reported slightly better outcomes as very few ISTCs participated, case-mix adjustment might have been insufficient, and patients' reports might have been biased as they were more likely to be satisfied with the way they were treated
An Objective Scatter Index Based on Double-Pass Retinal Images of a Point Source to Classify Cataracts
PURPOSE: To propose a new objective scatter index (OSI) based in the analysis of double-pass images of a point source to rank and classify cataract patients. This classification scheme is compared with a current subjective system. METHODS: We selected a population including a group of normal young eyes as control and patients diagnosed with cataract (grades NO2, NO3 and NO4) according to the Lens Opacities Classification System (LOCS III). For each eye, we recorded double-pass retinal images of a point source. In each patient, we determined an objective scatter index (OSI) as the ratio of the intensity at an eccentric location in the image and the central part. This index provides information on the relevant forward scatter affecting vision. Since the double-pass retinal images are affected by both ocular aberrations and intraocular scattering, an analysis was performed to show the ranges of contributions of aberrations to the OSI. RESULTS: We used the OSI values to classify each eye according to the degree of scatter. The young normal eyes of the control group had OSI values below 1, while the OSI for subjects in LOCS grade II were around 1 to 2. The use of the objective index showed some of the weakness of subjective classification schemes. In particular, several subjects initially classified independently as grade NO2 or NO3 had similar OSI values, and in some cases even higher than subjects classified as grade NO4. A new classification scheme based in OSI is proposed. CONCLUSIONS: We introduced an objective index based in the analysis of double-pass retinal images to classify cataract patients. The method is robust and fully based in objective measurements; i.e., not depending on subjective decisions. This procedure could be used in combination with standard current methods to improve cataract patient surgery scheduling
Measuring benefits and patients' satisfaction when glasses are not needed after cataract and presbyopia surgery: scoring and psychometric validation of the Freedom from Glasses Value Scale (FGVS©)
<p>Abstract</p> <p>Background</p> <p>The purpose of this study was to reduce the number of items, create a scoring method and assess the psychometric properties of the Freedom from Glasses Value Scale (FGVS), which measures benefits of freedom from glasses perceived by cataract and presbyopic patients after multifocal intraocular lens (IOL) surgery.</p> <p>Methods</p> <p>The 21-item FGVS, developed simultaneously in French and Spanish, was administered by phone during an observational study to 152 French and 152 Spanish patients who had undergone cataract or presbyopia surgery at least 1 year before the study. Reduction of items and creation of the scoring method employed statistical methods (principal component analysis, multitrait analysis) and content analysis. Psychometric properties (validation of the structure, internal consistency reliability, and known-group validity) of the resulting version were assessed in the pooled population and per country.</p> <p>Results</p> <p>One item was deleted and 3 were kept but not aggregated in a dimension. The other 17 items were grouped into 2 dimensions ('global evaluation', 9 items; 'advantages', 8 items) and divided into 5 sub-dimensions, with higher scores indicating higher benefit of surgery. The structure was validated (good item convergent and discriminant validity). Internal consistency reliability was good for all dimensions and sub-dimensions (Cronbach's alphas above 0.70). The FGVS was able to discriminate between patients wearing glasses or not after surgery (higher scores for patients not wearing glasses). FGVS scores were significantly higher in Spain than France; however, the measure had similar psychometric performances in both countries.</p> <p>Conclusions</p> <p>The FGVS is a valid and reliable instrument measuring benefits of freedom from glasses perceived by cataract and presbyopic patients after multifocal IOL surgery.</p
Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV
The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≥20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≤pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≤{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration
Search for R-parity-violating supersymmetry in events with four or more leptons in sqrt(s) =7 TeV pp collisions with the ATLAS detector
A search for new phenomena in final states with four or more leptons (electrons or muons) is presented. The analysis is based on 4.7 fb−1 of proton-proton collisions delivered by the Large Hadron Collider and recorded with the ATLAS detector. Observations are consistent with Standard Model expectations in two signal regions: one that requires moderate values of missing transverse momentum and another that requires large effective mass. The results are interpreted in a simplified model of R-parity-violating supersymmetry in which a 95% CL exclusion region is set for charged wino masses up to 540 GeV. In an R-parity-violating MSUGRA/CMSSM model, values of m 1/2 up to 820 GeV are excluded for 10 < tan β < 40
- …