431 research outputs found

    Testing for negligible interaction: A coherent and robust approach.

    Get PDF
    Researchers often want to demonstrate a lack of interaction between two categorical predictors on an outcome. To justify a lack of interaction, researchers typically accept the null hypothesis of no interaction from a conventional analysis of variance (ANOVA). This method is inappropriate as failure to reject the null hypothesis does not provide statistical evidence to support a lack of interaction. This study proposes a bootstrap-based intersection-union test for negligible interaction that provides coherent decisions between the omnibus test and post hoc interaction contrast tests and is robust to violations of the normality and variance homogeneity assumptions. Further, a multiple comparison strategy for testing interaction contrasts following a nonsignificant omnibus test is proposed. Our simulation study compared the Type I error control, omnibus power and per-contrast power of the proposed approach to the noncentrality-based negligible interaction test of Cheng and Shao (2007). For 2 x 2 designs, the empirical Type I error rates of the Cheng and Shao test were very close to the nominal α level when the normality and variance homogeneity assumptions were satisfied, however only our proposed bootstrapping approach was satisfactory under nonnormality and/or variance heterogeneity. In general a x b designs, although the omnibus Cheng and Shao test, as expected, is the most powerful, it is not robust to assumption violation and results in incoherent omnibus and interaction contrast decisions that are not possible with the intersection-union approach.Social Sciences and Humanities Research Council of Canad

    Selection of suitable reference genes for quantitative real-time polymerase chain reaction in human meningiomas and arachnoidea

    Get PDF
    <p>Abstract</p> <p>Findings</p> <p>At first 32 housekeeping genes were analyzed in six randomly chosen meningiomas, brain and dura mater using geNorm, NormFinder, Bestkeeper-1 software and the comparative ΔCt method. Reference genes were ranked according to an integration tool for analyzing reference genes expression based on those four algorithms. Eight highest ranked reference genes (CASC3, EIF2B1, IPO8, MRPL19, PGK1, POP4, PPIA, and RPL37A) plus GAPDH and ACTB were then analyzed in 35 meningiomas, arachnoidea, dura mater and normal brain. NormFinder and Bestkeeper-1 identified RPL37A as the most stable expressed gene in meningiomas and their normal control tissue. NormFinder also determined the best combination of genes: RPL37A and EIF2B1. Commonly used reference genes GAPDH and ACTB were considered least stable genes. The critical influence of reference genes on qPCR data analysis is shown for VEGFA transcription patterns.</p> <p>Background</p> <p>In meningiomas quantitative real-time reverse transcription-polymerase chain reaction (qPCR) is most frequently used for accurate determination of gene expression using various reference genes. Although meningiomas are a heterogeneous group of tissue, no data have been reported to validate reference genes for meningiomas and their control tissues.</p> <p>Conclusions</p> <p>RPL37A is the optimal single reference gene for normalization of gene expression in meningiomas and their control tissues, although the use of the combination of RPL37A and EIF2B1 would provide more stable results.</p

    A Method to Quantify Mouse Coat-Color Proportions

    Get PDF
    Coat-color proportions and patterns in mice are used as assays for many processes such as transgene expression, chimerism, and epigenetics. In many studies, coat-color readouts are estimated from subjective scoring of individual mice. Here we show a method by which mouse coat color is quantified as the proportion of coat shown in one or more digital images. We use the yellow-agouti mouse model of epigenetic variegation to demonstrate this method. We apply this method to live mice using a conventional digital camera for data collection. We use a raster graphics editing program to convert agouti regions of the coat to a standard, uniform, brown color and the yellow regions of the coat to a standard, uniform, yellow color. We use a second program to quantify the proportions of these standard colors. This method provides quantification that relates directly to the visual appearance of the live animal. It also provides an objective analysis with a traceable record, and it should allow for precise comparisons of mouse coats and mouse cohorts within and between studies

    Equivalence tests for comparing correlation and regression coefficients

    Get PDF
    Equivalence tests are an alternative to traditional difference-based tests for demonstrating a lack of association between two variables. While there are several recent studies investigating equivalence tests for comparing means, little research has been conducted on equivalence methods for evaluating the equivalence or similarity of two correlation coefficients or two regression coefficients. The current project proposes novel tests for evaluating the equivalence of two regression or correlation coefficients derived from the two one-sided tests (TOST) method (Schuirmann, 1987, J. Pharmacokinet. Biopharm, 15, 657) and an equivalence test by Anderson and Hauck (1983, Stat. Commun., 12, 2663). A simulation study was used to evaluate the performance of these tests and compare them with the common, yet inappropriate, method of assessing equivalence using nonrejection of the null hypothesis in difference-based tests. Results demonstrate that equivalence tests have more accurate probabilities of declaring equivalence than difference-based tests. However, equivalence tests require large sample sizes to ensure adequate power. We recommend the Anderson–Hauck equivalence test over the TOST method for comparing correlation or regression coefficients.Social Sciences and Humanities Research Council (SSHRC

    Bioavailability of Orally Administered rhGM-CSF: A Single-Dose, Randomized, Open-Label, Two-Period Crossover Trial

    Get PDF
    BACKGROUND: Recombinant human granulocyte-macrophage colony-stimulating factor (rhGM-CSF) is usually administered by injection, and its oral administration in a clinical setting has been not yet reported. Here we demonstrate the bioavailability of orally administered rhGM-CSF in healthy volunteers. The rhGM-CSF was expressed in Bombyx mori expression system (BmrhGM-CSF). METHODS AND FINDINGS: Using a single-dose, randomized, open-label, two-period crossover clinical trial design, 19 healthy volunteers were orally administered with BmrhGM-CSF (8 microg/kg) and subcutaneously injected with rhGM-CSF (3.75 microg/kg) respectively. Serum samples were drawn at 0.0h, 0.5h ,0.75h,1.0h,1.5h,2.0h ,3.0h,4.0h,5.0h,6.0h,8.0h,10.0h and 12.0h after administrations. The hGM-CSF serum concentrations were determined by ELISA. The AUC was calculated using the trapezoid method. The relative bioavailability of BmrhGM-CSF was determined according to the AUC ratio of both orally administered and subcutaneously injected rhGM-CSF. Three volunteers were randomly selected from 15 orally administrated subjects with ELISA detectable values. Their serum samples at the 0.0h, 1.0h, 2.0h, 3.0h and 4.0h after the administrations were analyzed by Q-Trap MS/MS TOF. The different peaks were revealed by the spectrogram profile comparison of the 1.0h, 2.0h, 3.0h and 4.0h samples with that of the 0.0h sample, and further analyzed using both Enhanced Product Ion (EPI) scanning and Peptide Mass Fingerprinting Analysis. The rhGM-CSF was detected in the serum samples from 15 of 19 volunteers administrated with BmrhGM-CSF. Its bioavailability was observed at an average of 1.0%, with the highest of 3.1%. The rhGM-CSF peptide sequences in the serum samples were detected by MS analysis, and their sizes ranging from 2,039 to 7,336 Da. CONCLUSIONS: The results demonstrated that the oral administered BmrhGM-CSF was absorbed into the blood. This study provides an approach for an oral administration of rhGM-CSF protein in clinical settings. TRIAL REGISTRATION: www.chictr.orgChiCTR-TRC-00000107

    Covering Chemical Diversity of Genetically-Modified Tomatoes Using Metabolomics for Objective Substantial Equivalence Assessment

    Get PDF
    As metabolomics can provide a biochemical snapshot of an organism's phenotype it is a promising approach for charting the unintended effects of genetic modification. A critical obstacle for this application is the inherently limited metabolomic coverage of any single analytical platform. We propose using multiple analytical platforms for the direct acquisition of an interpretable data set of estimable chemical diversity. As an example, we report an application of our multi-platform approach that assesses the substantial equivalence of tomatoes over-expressing the taste-modifying protein miraculin. In combination, the chosen platforms detected compounds that represent 86% of the estimated chemical diversity of the metabolites listed in the LycoCyc database. Following a proof-of-safety approach, we show that % had an acceptable range of variation while simultaneously indicating a reproducible transformation-related metabolic signature. We conclude that multi-platform metabolomics is an approach that is both sensitive and robust and that it constitutes a good starting point for characterizing genetically modified organisms

    Asymmetric inner wedge group sequential tests with applications to verifying whether effective drug concentrations are similar in adults and children

    Get PDF
    Extrapolating from information available on one patient group to support conclusions about another is common in clinical research. For example, the findings of clinical trials, often conducted in highly selective patient cohorts, are routinely extrapolated to wider populations by policy makers. Meanwhile, the results of adult trials may be used to support conclusions about the effects of a medicine in children. For example, if the effective concentration of a drug can be assumed to be similar in adults and children, an appropriate paediatric dosing rule may be found by ‘bridging’, that is, by matching the adult effective concentration. However, this strategy may result in children receiving an ineffective or hazardous dose if, in fact, effective concentrations differ between adults and children. When there is uncertainty about the equality of effective concentrations, some pharmacokinetic–pharmacodynamic data may be needed in children to verify that differences are small. In this paper, we derive optimal group sequential tests that can be used to verify this assumption efficiently. Asymmetric inner wedge tests are constructed that permit early stopping to accept or reject an assumption of similar effective drug concentrations in adults and children. Asymmetry arises because the consequences of under- and over-dosing may differ. We show how confidence intervals can be obtained on termination of these tests and illustrate the small sample operating characteristics of designs using simulation

    Diagnostic Value of Lumbar Facet Joint Injection: A Prospective Triple Cross-Over Study

    Get PDF
    The diagnosis “lumbar facet syndrome” is common and often indicates severe lumbar spine surgery procedures. It is doubtful whether a painful facet joint (FJ) can be identified by a single FJ block. The aim of this study was to clarify the validity of a single and placebo controlled bilateral FJ blocks using local anesthetics. A prospective single blinded triple cross-over study was performed. 60 patients (31 f, 29 m, mean age 53.2 yrs (22–73)) with chronic low back pain (mean pain persistance 31 months, 6 months of conservative treatment without success) admitted to a local orthopaedic department for surgical or conservative therapy of chronic LBP, were included in the study. Effect on pain reduction (10 point rating scale) was measured. The 60 subjects were divided into six groups with three defined sequences of fluoroscopically guided bilateral monosegmental lumbar FJ test injections in “oblique needle” technique: verum-(local anaesthetic-), placebo-(sodium chloride-) and sham-injection. Carry-over and periodic effects were evaluated and a descriptive and statistical analysis regarding the effectiveness, difference and equality of the FJ injections and the different responses was performed. The results show a high rate of non-response, which documents the lack of reliable and valid predictors for a positive response towards FJ blocks. There was a high rate of placebo reactions noted, including subjects who previously or later reacted positively to verum injections. Equivalence was shown among verum vs. placebo and partly vs. sham also. With regard to test validity criteria, a single intraarticular FJ block with local anesthetics is not useful to detect the pain-responsible FJ and therefore is no valid and reliable diagostic tool to specify indication of lumbar spine surgery. Comparative FJ blocks with local anesthetics and placebo-controls have to be interpretated carefully also, because they solely give no proper diagnosis on FJ being main pain generator
    corecore