90 research outputs found
Venturi Flowmeter Performance Installed Downstream of the Branch of a Tee Junction
The purpose of this research was to evaluate the influence of a tee junction on flow rate measurement of a Venturi flowmeter installed downstream of the branch of a tee. Accuracy in flow measurement is important to organizations where miscalculated flow rates can add up to be millions of dollars in either lost revenue, overcharges to the client, or improper system operation. This research used Computational Fluid Dynamics (CFD) to determine ratios by which the manufacturerâs straight-line calibrated Cd (discharge coefficient) can be adjusted to improve the accuracy of the flow measurement when the Venturi is installed on the branch of a tee. Physical laboratory data was obtained for a 6-in. Venturi in a straight-line, followed by installation on the branch of a tee at zero pipe diameters and five pipe diameters downstream. CFD modeling was then used.
Results show the flow rate measurement was less affected when all flow was entering the tee branch and more affected when less flow was entering the tee branch. While physical laboratory calibration is still the best way to get the most accurate flow measurement performance for a Venturi, using CFD to create contour plots of Cd ratios to adjust manufacturer given Cds over a range of Reynolds numbers and flow splits entering the tee could be an option
Single-cell transcriptomics uncovers distinct molecular signatures of stem cells in chronic myeloid leukemia
Recent advances in single-cell transcriptomics are ideally placed to unravel intratumoral heterogeneity and selective resistance of cancer stem cell (SC) subpopulations to molecularly targeted cancer therapies. However, current single-cell RNA-sequencing approaches lack the sensitivity required to reliably detect somatic mutations. We developed a method that combines high-sensitivity mutation detection with whole-transcriptome analysis of the same single cell. We applied this technique to analyze more than 2,000 SCs from patients with chronic myeloid leukemia (CML) throughout the disease course, revealing heterogeneity of CML-SCs, including the identification of a subgroup of CML-SCs with a distinct molecular signature that selectively persisted during prolonged therapy. Analysis of nonleukemic SCs from patients with CML also provided new insights into cell-extrinsic disruption of hematopoiesis in CML associated with clinical outcome. Furthermore, we used this single-cell approach to identify a blast-crisis-specific SC population, which was also present in a subclone of CML-SCs during the chronic phase in a patient who subsequently developed blast crisis. This approach, which might be broadly applied to any malignancy, illustrates how single-cell analysis can identify subpopulations of therapy-resistant SCs that are not apparent through cell-population analysis
A red knot as a black swan:How a single bird shows navigational abilities during repeat crossings of the Greenland Icecap
Despite the wealth of studies on seasonal movements of birds between southern nonbreeding locations and High Arctic breeding locations, the key mechanisms of navigation during these migrations remain elusive. A flight along the shortest possible route between pairs of points on a sphere ('orthodrome') requires a bird to be able to assess its current location in relation to its migration goal and to make continuous adjustment of heading to reach that goal. Alternatively, birds may navigate along a vector with a fixed orientation ('loxodrome') based on magnetic and/or celestial compass mechanisms. Compass navigation is considered especially challenging for summer migrations in Polar regions, as continuous daylight and complexity in the geomagnetic field may complicate the use of both celestial and magnetic compasses here. We examine the possible use of orientation mechanisms during migratory flights across the Greenland Icecap. Using a novel 2 g solar-powered satellite transmitter, we documented the flight paths travelled by a female red knotCalidris canutus islandicaduring two northward and two southward migrations. The geometry of the paths suggests that red knots can migrate across the Greenland Icecap along the shortest-, orthodrome-like, path instead of the previously suggested loxodrome path. This particular bird's ability to return to locations visited in a previous year, together with its sudden course changes (which would be appropriate responses to ambient wind fields), suggest a map sense that enables red knots to determine location, so that they can tailor their route depending on local conditions
Search for gravitational wave bursts in LIGO's third science run
We report on a search for gravitational wave bursts in data from the three
LIGO interferometric detectors during their third science run. The search
targets subsecond bursts in the frequency range 100-1100 Hz for which no
waveform model is assumed, and has a sensitivity in terms of the
root-sum-square (rss) strain amplitude of hrss ~ 10^{-20} / sqrt(Hz). No
gravitational wave signals were detected in the 8 days of analyzed data.Comment: 12 pages, 6 figures. Amaldi-6 conference proceedings to be published
in Classical and Quantum Gravit
Measurement of b hadron lifetimes in exclusive decays containing a J/psi in p-pbar collisions at sqrt(s)=1.96TeV
We report on a measurement of -hadron lifetimes in the fully reconstructed
decay modes B^+ -->J/Psi K+, B^0 --> J/Psi K*, B^0 --> J/Psi Ks, and Lambda_b
--> J/Psi Lambda using data corresponding to an integrated luminosity of 4.3
, collected by the CDF II detector at the Fermilab Tevatron. The
measured lifetimes are B^+ = , B^0 = and Lambda_b = . The lifetime ratios are B^+/B^0 = and Lambda_b/B^0 = . These are the most precise determinations
of these quantities from a single experiment.Comment: revised version. accepted for PRL publicatio
Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector
Measurements of electrons from interactions are crucial for the Deep
Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as
searches for physics beyond the standard model, supernova neutrino detection,
and solar neutrino measurements. This article describes the selection and
reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector.
ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and
operated at CERN as a charged particle test beam experiment. A sample of
low-energy electrons produced by the decay of cosmic muons is selected with a
purity of 95%. This sample is used to calibrate the low-energy electron energy
scale with two techniques. An electron energy calibration based on a cosmic ray
muon sample uses calibration constants derived from measured and simulated
cosmic ray muon events. Another calibration technique makes use of the
theoretically well-understood Michel electron energy spectrum to convert
reconstructed charge to electron energy. In addition, the effects of detector
response to low-energy electron energy scale and its resolution including
readout electronics threshold effects are quantified. Finally, the relation
between the theoretical and reconstructed low-energy electron energy spectrum
is derived and the energy resolution is characterized. The low-energy electron
selection presented here accounts for about 75% of the total electron deposited
energy. After the addition of lost energy using a Monte Carlo simulation, the
energy resolution improves from about 40% to 25% at 50~MeV. These results are
used to validate the expected capabilities of the DUNE far detector to
reconstruct low-energy electrons.Comment: 19 pages, 10 figure
Impact of cross-section uncertainties on supernova neutrino spectral parameter fitting in the Deep Underground Neutrino Experiment
A primary goal of the upcoming Deep Underground Neutrino Experiment (DUNE) is
to measure the MeV neutrinos produced by a Galactic
core-collapse supernova if one should occur during the lifetime of the
experiment. The liquid-argon-based detectors planned for DUNE are expected to
be uniquely sensitive to the component of the supernova flux, enabling
a wide variety of physics and astrophysics measurements. A key requirement for
a correct interpretation of these measurements is a good understanding of the
energy-dependent total cross section for charged-current
absorption on argon. In the context of a simulated extraction of
supernova spectral parameters from a toy analysis, we investigate the
impact of modeling uncertainties on DUNE's supernova neutrino
physics sensitivity for the first time. We find that the currently large
theoretical uncertainties on must be substantially reduced
before the flux parameters can be extracted reliably: in the absence of
external constraints, a measurement of the integrated neutrino luminosity with
less than 10\% bias with DUNE requires to be known to about 5%.
The neutrino spectral shape parameters can be known to better than 10% for a
20% uncertainty on the cross-section scale, although they will be sensitive to
uncertainties on the shape of . A direct measurement of
low-energy -argon scattering would be invaluable for improving the
theoretical precision to the needed level.Comment: 25 pages, 21 figure
Search for High Mass Resonances Decaying to Muon Pairs in root s=1.96 TeV p(p)over-bar Collisions
We present a search for a new narrow, spin-1, high mass resonance decaying to mu(+)mu(-) + X, using a matrix-element-based likelihood and a simultaneous measurement of the resonance mass and production rate. In data with 4.6 fb(-1) of integrated luminosity collected by the CDF detector in p (p) over bar collisions at root s = 1960 GeV, the most likely signal cross section is consistent with zero at 16% confidence level. We therefore do not observe evidence for a high mass resonance and place limits on models predicting spin-1 resonances, including M > 1071 GeV/c(2) at 95% confidence level for a Z' boson with the same couplings to fermions as the Z boson
Measurement of b Hadron Lifetimes in Exclusive Decays Containing a J/Psi in p(p)over-bar Collisions at root s=1.96 TeV
We report on a measurement of b-hadron lifetimes in the fully reconstructed decay modes B+-> J/psi K+, B-0 -> J/psi K*(892)(0), B-0 -> J/psi K-s(0), and Lambda(0)(b)-> J/psi Lambda(0) using data corresponding to an integrated luminosity of 4.3 fb(-1), collected by the CDF II detector at the Fermilab Tevatron. The measured lifetimes are tau(B+)=[1.639 +/- 0.009(stat)+/- 0.009(syst)]ps, tau(B-0)=[1.507 +/- 0.010(stat)+/- 0.008(syst)]ps, and tau(Lambda(0)(b))=[1.537 +/- 0.045(stat)+/- 0.014(syst)]ps. The lifetime ratios are tau(B+)/tau(B-0)=[1.088 +/- 0.009(stat)+/- 0.004(syst)] and tau(Lambda(0)(b))/tau(B-0)=[1.020 +/- 0.030(stat)+/- 0.008(syst)]. These are the most precise determinations of these quantities from a single experiment
Highly-parallelized simulation of a pixelated LArTPC on a GPU
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on 10^3 pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype
- âŠ