587 research outputs found
Selling Zoning: Do Density Bonus Incentives for Moderate-Cost Housing Work
This Article reviews the housing affordability problem, the California legislation, and previous research findings. The Article outlines our methods, presents our results, and recommends program improvements
Consistent Factorization of Jet Observables in Exclusive Multijet Cross-Sections
We demonstrate the consistency at the next-to-leading-logarithmic (NLL) level
of a factorization theorem based on Soft-Collinear Effective Theory (SCET) for
jet shapes in e+e- collisions. We consider measuring jet observables in
exclusive multijet final states defined with cone and k_T-type jet algorithms.
Consistency of the factorization theorem requires that the renormalization
group evolution of hard, jet, and soft functions is such that the physical
cross-section is independent of the factorization scale mu. The anomalous
dimensions of the various factorized pieces, however, depend on the color
representation of jets, choice of jet observable, the number of jets whose
shapes are measured, and the jet algorithm, making it highly nontrivial to
satisfy the consistency condition. We demonstrate the intricate cancellations
between anomalous dimensions that occur at the NLL level, so that, up to power
corrections that we identify, our factorization of the jet shape distributions
is consistent for any number of quark and gluon jets, for any number of jets
whose shapes are measured or unmeasured, for any angular size R of the jets,
and for any of the algorithms we consider. Corrections to these results are
suppressed by the SCET expansion parameter lambda (the ratio of soft to
collinear or collinear to hard scales) and in the jet separation measure 1/t^2
= tan^2(R/2)/tan^2(psi/2), where psi is the angular separation between jets.
Our results can be used to calculate a wide variety of jet observables in
multijet final states to NLL accuracy.Comment: 8 pages, 1 figure, uses elsarticle.cls; v2: minor edits, added
reference
XMM-Newton 13H Deep field - I. X-ray sources
We present the results of a deep X-ray survey conducted with XMM-Newton,
centred on the UK ROSAT 13H deep field area. This region covers 0.18 deg^2 and
is the first of two areas covered with XMM-Newton as part of an extensive
multi-wavelength survey designed to study the nature and evolution of the faint
X-ray source population. We have produced detailed Monte-Carlo simulations to
obtain a quantitative characterisation of the source detection procedure and to
assess the reliability of the resultant sourcelist. We use the simulations to
establish a likelihood threshold above which we expect less than 7 (3%) of our
sources to be spurious. We present the final catalogue of 225 sources. Within
the central 9 arcmin, 68 per cent of source positions are accurate to 2 arcsec,
making optical follow-up relatively straightforward. We construct the N(>S)
relation in four energy bands: 0.2-0.5 keV, 0.5-2 keV, 2-5 keV and 5-10 keV. In
all but our highest energy band we find that the source counts can be
represented by a double powerlaw with a bright end slope consistent with the
Euclidean case and a break around 10^-14 cgs. Below this flux the counts
exhibit a flattening. Our source counts reach densities of 700, 1300, 900 and
300 deg^-2 at fluxes of 4.1x10^-16, 4.5x10^-16, 1.1x10^-15 and 5.3x10^-15 cgs
in the 0.2-0.5, 0.5-2, 2-5 and 5-10 keV energy bands respectively. We have
compared our source counts with those in the two Chandra deep fields and
Lockman hole and find our source counts to be amongst the highest of these
fields in all energy bands. We resolve >51% (>50%) of the X-ray background
emission in the 1-2 keV (2-5 keV) energy bands.Comment: 27 pages, 18 figures, MNRAS accepte
Pulsatile Ocular Blood Flow in Healthy Koreans
PURPOSE: To determine the normal reference range of pulsatile ocular blood flow (POBF) values in healthy Korean subjects and to find out the factors that may affect them.
METHODS: A total of 280 eyes of 280 normal subjects were included in this study. Best corrected visual acuity (BCVA), intraocular pressure (IOP), axial length, POBF, systemic blood pressure, and pulse rate were measured. The mean, standard deviation, range, and the 5th and 95th percentiles of POBF were calculated, and the influences of various parameters to POBF were determined by multiple regression analyses.
RESULTS: The mean POBF value was 766.0+/-221.6 microl/min in men and 1021.1+/-249.5 microl/min in women. The 5th and 95th percentiles for POBF values were 486.0 microl/min and 1140.0 microl/min in men and 672.0 microl/min and 1458.0 microl/min in women. The POBF values were significantly influenced by gender, mean blood pressure, pulse rate, and axial length.
CONCLUSIONS: Even though the POBF values were influenced by gender, BP, and axial length, we could define the normal reference range of POBF in healthy Koreans.ope
Tumor Size Is Not Everything:Advancing Radiomics as a Precision Medicine Biomarker in Oncology Drug Development and Clinical Care. A Report of a Multidisciplinary Workshop Coordinated by the RECIST Working Group
Radiomics, the science of extracting quantifiable data from routine medical images, is a powerful tool that has many potential applications in oncology. The Response Evaluation Criteria in Solid Tumors Working Group (RWG) held a workshop in May 2022, which brought together various stakeholders to discuss the potential role of radiomics in oncology drug development and clinical trials, particularly with respect to response assessment. This article summarizes the results of that workshop, reviewing radiomics for the practicing oncologist and highlighting the work that needs to be done to move forward the incorporation of radiomics into clinical trials
Interpretation of uniocular and binocular trials of glaucoma medications: an observational case series
<p>Abstract</p> <p>Background</p> <p>To predict the effectiveness of topical glaucoma medications based on initial uniocular and binocular treatment. To test a traditional hypothesis that effectiveness following a uniocular trial is associated with the change in IOP in the initially treated eye minus the change in the initially untreated eye. To determine whether uniocular or binocular treatment trials are superior.</p> <p>Methods</p> <p>Based on a review of medical records, we identified 168 instances in 154 patients with bilateral primary open angle glaucoma of initial uniocular use of a topical glaucoma medication with well-documented intraocular pressure (IOP) readings at baseline (IOP<sub>A</sub>), during the trial (IOP<sub>B</sub>), and at follow-up (IOP<sub>C</sub>). Abstracted data included demographic data, IOP, and medication use. Predictors of the IOP following the trial (IOP<sub>C</sub>) in each eye were identified by multivariable linear regression. In 70 cases, the predictive ability of initial uniocular and binocular treatment could be directly compared.</p> <p>Results</p> <p>In a multivariable analysis, the follow-up pressure in the initially treated eye (IOP<sub>1C</sub>) was directly correlated with treated eye IOP during initial uniocular use (IOP<sub>1B</sub>, p < 0.001). In a multivariable analysis, the follow-up pressure in the initially untreated eye (IOP<sub>2C</sub>) was directly correlated with its baseline IOP<sub>2A </sub>(p < 0.001), and also tended to be associated with treated IOP<sub>1B </sub>(p = 0.07). The multivariable regression coefficient (b) for the IOP change in the initially untreated eye was generally not close to the value of -1 expected by the classic teaching (for eye 1, b = 0.04, p = 0.35; for eye 2, b = 0.07, p = 0.50). In 70 cases, the uniocular and binocular trials predicted a similar fraction of the variance in follow-up IOP<sub>1C </sub>(r<sup>2 </sup>= 0.56 and 0.57, respectively) and IOP<sub>2C </sub>(r<sup>2 </sup>= 0.39 and 0.38, respectively).</p> <p>Conclusion</p> <p>1) For uniocular trials, the IOP change in the untreated eye should not be subtracted from that in the treated eye. 2) Uniocular and binocular trials have similar predictive value when interpreted correctly. Either may be selected based on clinical circumstances.</p
Jet Shapes and Jet Algorithms in SCET
Jet shapes are weighted sums over the four-momenta of the constituents of a
jet and reveal details of its internal structure, potentially allowing
discrimination of its partonic origin. In this work we make predictions for
quark and gluon jet shape distributions in N-jet final states in e+e-
collisions, defined with a cone or recombination algorithm, where we measure
some jet shape observable on a subset of these jets. Using the framework of
Soft-Collinear Effective Theory, we prove a factorization theorem for jet shape
distributions and demonstrate the consistent renormalization-group running of
the functions in the factorization theorem for any number of measured and
unmeasured jets, any number of quark and gluon jets, and any angular size R of
the jets, as long as R is much smaller than the angular separation between
jets. We calculate the jet and soft functions for angularity jet shapes \tau_a
to one-loop order (O(alpha_s)) and resum a subset of the large logarithms of
\tau_a needed for next-to-leading logarithmic (NLL) accuracy for both cone and
kT-type jets. We compare our predictions for the resummed \tau_a distribution
of a quark or a gluon jet produced in a 3-jet final state in e+e- annihilation
to the output of a Monte Carlo event generator and find that the dependence on
a and R is very similar.Comment: 62 pages plus 21 pages of Appendices, 13 figures, uses JHEP3.cls. v2:
corrections to finite parts of NLO jet functions, minor changes to plots,
clarified discussion of power corrections. v3: Journal version. Introductory
sections significantly reorganized for clarity, classification of logarithmic
accuracy clarified, results for non-Mercedes-Benz configurations adde
- …