845 research outputs found
Effect of carnitine on muscular glutamate uptake and intramuscular glutathione in malignant diseases
Abnormally low intramuscular glutamate and glutathione (GSH) levels and/or a decreased muscular uptake of glutamate by the skeletal muscle tissue have previously been found in malignant diseases and simian immunodeficiency virus (SIV) infection and may contribute to the development of cachexia. We tested the hypothesis that an impaired mitochondrial energy metabolism may compromise the Na+-dependent glutamate transport. A randomized double-blind clinical trial was designed to study the effects of L -carnitine, i.e. an agent known to enhance mitochondrial integrity and function, on the glutamate transport and plasma glutamate level of cancer patients. The effect of carnitine on the intramuscular glutamate and GSH levels was examined in complementary experiments with tumour-bearing mice. In the mice, L -carnitine treatment ameliorated indeed the tumour-induced decrease in muscular glutamate and GSH levels and the increase in plasma glutamate levels. The carnitine-treated group in the randomized clinical study showed also a significant decrease in the plasma glutamate levels but only a moderate and statistically not significant increase in the relative glutamate uptake in the lower extremities. Further studies may be warranted to determine the effect of L -carnitine on the intramuscular GSH levels in cancer patients. Š 2000 Cancer Research Campaig
In-depth clinical and biological exploration of DNA Damage Immune Response (DDIR) as a biomarker for oxaliplatin use in colorectal cancer
PURPOSE: The DNA Damage Immune Response (DDIR) assay was developed in breast cancer (BC) based on biology associated with deficiencies in homologous recombination and Fanconi Anemia (HR/FA) pathways. A positive DDIR call identifies patients likely to respond to platinum-based chemotherapies in breast and oesophageal cancers. In colorectal cancer (CRC) there is currently no biomarker to predict response to oxaliplatin. We tested the ability of the DDIR assay to predict response to oxaliplatin-based chemotherapy in CRC and characterised the biology in DDIR-positive CRC. METHODS: Samples and clinical data were assessed according to DDIR status from patients who received either 5FU or FOLFOX within the FOCUS trial (n=361, stage 4), or neo-adjuvant FOLFOX in the FOxTROT trial (n=97, stage 2/3). Whole transcriptome, mutation and immunohistochemistry data of these samples were used to interrogate the biology of DDIR in CRC. RESULTS: Contrary to our hypothesis, DDIR negative patients displayed a trend towards improved outcome for oxaliplatin-based chemotherapy compared to DDIR positive patients. DDIR positivity was associated with Microsatellite Instability (MSI) and Colorectal Molecular Subtype 1 (CMS1). Refinement of the DDIR signature, based on overlapping interferon-related chemokine signalling associated with DDIR positivity across CRC and BC cohorts, further confirmed that the DDIR assay did not have predictive value for oxaliplatin-based chemotherapy in CRC. CONCLUSIONS: DDIR positivity does not predict improved response following oxaliplatin treatment in CRC. However, data presented here suggests the potential of the DDIR assay in identifying immune-rich tumours that may benefit from immune checkpoint blockade, beyond current use of MSI status
Does delayed measurement affect patient reports of provider performance? Implications for performance measurement of medical assistance with tobacco cessation: A Dental PBRN study
<p>Abstract</p> <p>Background:</p> <p>We compared two methods of measuring provider performance of tobacco control activities: immediate "exit cards" versus delayed telephone follow-up surveys. Current standards, e.g. HEDIS, use delayed patient measures that may over or under-estimate overall performance.</p> <p>Methods:</p> <p>Patients completed exit cards in 60 dental practices immediately after a visit to measure whether the provider "asked" about tobacco use, and "advised" the patient to quit. One to six months later patients were asked the same questions by telephone survey. Using the exit cards as the standard, we quantified performance and calculated sensitivity (agreement of those responding yes on telephone surveys compared with exit cards) and specificity (agreement of those responding no) of the delayed measurement.</p> <p>Results:</p> <p>Among 150 patients, 21% reporting being asked about tobacco use on the exit cards and 30% reporting being asked in the delayed surveys. The sensitivity and specificity were 50% and 75%, respectively. Similarly, among 182 tobacco users, 38% reported being advised to quit on the exit cards and this increased to 51% on the delayed surveys. The sensitivity and specificity were 75% and 64%, respectively. Increasing the delay from the visit to the telephone survey resulted in increasing disagreement.</p> <p>Conclusion:</p> <p>Patient reports differed considerably in immediate versus delayed measures. These results have important implications because they suggest that our delayed measures may over-estimate performance. The immediate exit cards should be included in the armamentarium of tools for measuring providers' performance of tobacco control, and perhaps other service delivery.</p
Evidence-based nanoscopic and molecular framework for excipient functionality in compressed orally disintegrating tablets
The work investigates the adhesive/cohesive molecular and physical interactions together with nanoscopic features of commonly used orally disintegrating tablet (ODT) excipients microcrystalline cellulose (MCC) and D-mannitol. This helps to elucidate the underlying physico-chemical and mechanical mechanisms responsible for powder densification and optimum product functionality. Atomic force microscopy (AFM) contact mode analysis was performed to measure nano-adhesion forces and surface energies between excipient-drug particles (6-10 different particles per each pair). Moreover, surface topography images (100 nm2-10 Οm2) and roughness data were acquired from AFM tapping mode. AFM data were related to ODT macro/microscopic properties obtained from SEM, FTIR, XRD, thermal analysis using DSC and TGA, disintegration testing, Heckel and tabletability profiles. The study results showed a good association between the adhesive molecular and physical forces of paired particles and the resultant densification mechanisms responsible for mechanical strength of tablets. MCC micro roughness was 3 times that of D-mannitol which explains the high hardness of MCC ODTs due to mechanical interlocking. Hydrogen bonding between MCC particles could not be established from both AFM and FTIR solid state investigation. On the contrary, D-mannitol produced fragile ODTs due to fragmentation of surface crystallites during compression attained from its weak crystal structure. Furthermore, AFM analysis has shown the presence of extensive micro fibril structures inhabiting nano pores which further supports the use of MCC as a disintegrant. Overall, excipients (and model drugs) showed mechanistic behaviour on the nano/micro scale that could be related to the functionality of materials on the macro scale. Š 2014 Al-khattawi et al
Measurement of D-s(+) and D-s(*+) production in B meson decays and from continuum e(+)e(-) annihilation at âs=10.6 GeV
This is the pre-print version of the Article. The official published version can be accessed from the links below. Copyright @ 2002 APSNew measurements of Ds+ and Ds*+ meson production rates from B decays and from qqĚ
continuum events near the ÎĽ(4S) resonance are presented. Using 20.8 fb-1 of data on the ÎĽ(4S) resonance and 2.6 fb-1 off-resonance, we find the inclusive branching fractions B(BâDs+X)=(10.93Âą0.19Âą0.58Âą2.73)% and B(BâDs*+X)=(7.9Âą0.8Âą0.7Âą2.0)%, where the first error is statistical, the second is systematic, and the third is due to the Ds+âĎĎ+ branching fraction uncertainty. The production cross sections Ď(e+e-âDs+X)ĂB(Ds+âĎĎ+)=7.55Âą0.20Âą0.34pb and Ď(e+e-âDs*ÂąX)ĂB(Ds+âĎĎ+)=5.8Âą0.7Âą0.5pb are measured at center-of-mass energies about 40 MeV below the ÎĽ(4S) mass. The branching fractions ÎŁB(BâDs(*)+D(*))=(5.07Âą0.14Âą0.30Âą1.27)% and ÎŁB(BâDs*+D(*))=(4.1Âą0.2Âą0.4Âą1.0)% are determined from the Ds(*)+ momentum spectra. The mass difference m(Ds+)-m(D+)=98.4Âą0.1Âą0.3MeV/c2 is also measured.This work was supported by DOE and NSF (USA), NSERC (Canada), IHEP (China), CEA and CNRS-IN2P3 (France), BMBF (Germany), INFN (Italy), NFR (Norway), MIST (Russia), and PPARC (United Kingdom). Individuals have received support from the Swiss NSF, A. P. Sloan Foundation, Research Corporation, and Alexander von Humboldt Foundation
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy
A search for new physics is performed in events with two same-sign isolated
leptons, hadronic jets, and missing transverse energy in the final state. The
analysis is based on a data sample corresponding to an integrated luminosity of
4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of
7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of
140 increase in integrated luminosity over previously published results. The
observed yields agree with the standard model predictions and thus no evidence
for new physics is found. The observations are used to set upper limits on
possible new physics contributions and to constrain supersymmetric models. To
facilitate the interpretation of the data in a broader range of new physics
scenarios, information on the event selection, detector response, and
efficiencies is provided.Comment: Published in Physical Review Letter
Compressed representation of a partially defined integer function over multiple arguments
In OLAP (OnLine Analitical Processing) data are analysed in an n-dimensional cube. The cube may be represented as a partially defined function over n arguments. Considering that often the function is not defined everywhere, we ask: is there a known way of representing the function or the points in which it is defined, in a more compact manner than the trivial one
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV
The azimuthal anisotropy of charged particles in PbPb collisions at
nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS
detector at the LHC over an extended transverse momentum (pt) range up to
approximately 60 GeV. The data cover both the low-pt region associated with
hydrodynamic flow phenomena and the high-pt region where the anisotropies may
reflect the path-length dependence of parton energy loss in the created medium.
The anisotropy parameter (v2) of the particles is extracted by correlating
charged tracks with respect to the event-plane reconstructed by using the
energy deposited in forward-angle calorimeters. For the six bins of collision
centrality studied, spanning the range of 0-60% most-central events, the
observed v2 values are found to first increase with pt, reaching a maximum
around pt = 3 GeV, and then to gradually decrease to almost zero, with the
decline persisting up to at least pt = 40 GeV over the full centrality range
measured.Comment: Replaced with published version. Added journal reference and DO
- âŚ