1,744 research outputs found

    Voltage regulation considerations for the design of hybrid distribution transformers

    Get PDF
    The future substation depends on finding a way to mitigate the effects of the drawbacks of the conventional legacy by employing the efficiency of the solid state switches [1]. This paper discusses the considerations of designing a distribution transformer that provides additional functions in regulating the voltage and controlling the reactive power that is injected in the distribution network, using a fractional rated converter attached partially with the windings of the transformer. This approach aims mainly to enhance the unit with more flexibility in controlling the voltage at the last mile of the network, in order to decrease the losses and meet the future expectations for low voltage networks modifications, and that by using a power electronic (PE) approach has less losses and more functionality (depending on the reliability of transformer and intelligence of PE). The design of a hybrid distribution transformer is detailed and its functionality in regulating the voltage is discussed as a combination between the features of one of the most reliable network devices, the transformer, and the effect of PE existence with less losses in both switching and conduction losses. Reduced ratings PE are used in this approach, whereby the solid state switches are controlled according to the immediate need for voltage control in low voltage (LV) networks

    Gender-differences of in vitro colonic motility after chemo- and radiotherapy in humans.

    Get PDF
    Background: The aim of the present in vitro study was to investigate, in different genders, motor responses in surgical colonic specimens from patients with rectal cancer undergoing and not undergoing chemotherapy with capecitabine and radiotherapy. Methods: This in vitro study was conducted from October 2015 to August 2017 at the Experimental Pharmacology Laboratory at the National Institute “S. de Bellis” after collecting samples at the Department of Surgery. Segments of sigmoid colon were obtained from 15 patients (Male (M)/Female (F) = 8/7; control group, CG) operated on for elective colorectal resection for rectal cancer without obstruction and 14 patients (M/F = 7/7; study group, SG) operated on for elective colorectal resection for rectal cancer who also received chemotherapy, based on capecitabine twice daily, and radiotherapy. Isometric tension was measured on colonic circular muscle strips exposed to increasing carbachol or histamine concentrations to obtain concentration-response curves. The motor responses to electrically evoked stimulation were also investigated. Results: In males, carbachol and histamine caused concentration-dependent contractions in the CG and SG. An increased sensitivity and a higher response to carbachol and histamine were observed in SG than CG (P < 0.01). On the contrary, in females, the response to carbachol was not significantly different in CG from the SG and the maximal responses to carbachol were greater in CG than in SG (P < 0.001). The same applied to histamine for half-maximal effective concentrations and maximal response in that they were not significantly different in CG from the SG. Electrically evoked contractions were significantly more pronounced in males, especially in the SG (P < 0.05). Conclusions: This preliminary in vitro study has shown gender differences in motor responses of colonic circular muscle strips in patients who had received chemotherapy with capecitabine and radiotherapy

    Electrochemical determination of microRNAs based on isothermal strand-displacement polymerase reaction coupled with multienzyme functionalized magnetic micro-carriers

    Get PDF
    This study was supported by the National Natural Science Foundation of China (81371901), Doctoral Scientific Fund Project of the Ministry of Education of People's Republic of China (20134433110010), the Critical Point-of-Care Testing (CPOCT) Research grant of American Association for Clinical Chemistry (AACC) and 2015 Distinguished Academic Fellowships of Royal College of Engineering (DVF1415/2/79)

    Is mitral valve repair superior to replacement for chronic ischemic mitral regurgitation with left ventricular dysfunction?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This study was undertaken to compare mitral valve repair and replacement as treatments for ischemic mitral regurgitation (IMR) with left ventricular dysfunction (LVD). Specifically, we sought to determine whether the choice of mitral valve procedure affected survival, and discover which patients were predicted to benefit from mitral valve repair and which from replacement.</p> <p>Methods</p> <p>A total of 218 consecutive patients underwent either mitral valve repair (MVP, n = 112) or mitral valve replacement (MVR, n = 106). We retrospectively reviewed the clinical material, operation methods, echocardiography check during operation and follow-up. Patients details and follow-up outcomes were compared using multivariate and Kaplan-Meier analyses.</p> <p>Results</p> <p>No statistical difference was found between the two groups in term of intraoperative data. Early mortality was 3.2% (MVP 2.7% and MVR 3.8%). At discharge, Left ventricular end-systolic and end-diastolic diameter and left ventricular ejection fraction (LVEF) were improved more in the MVP group than MVR group (P < 0.05), however, in follow-up no statistically significant difference was observed between the MVR and MVP group (P > 0.05). Follow-up mitral regurgitation grade was significantly improved in the MVR group compared with the MVP group (P < 0.05). The Kaplan-Meier survival estimates at 1, 3, and 5 years were simlar between MVP and MVR group. Logistic regression revealed poor survival was associated with old age(#75), preoperative renal insufficiency and low left ventricular ejection fraction (< 30%).</p> <p>Conclusion</p> <p>Mitral valve repair is the procedure of choice in the majority of patients having surgery for severe ischemic mitral regurgitation with left ventricular dysfunction. Early results of MVP treatment seem to be satisfactory, but several lines of data indicate that mitral valve repair provided less long-term benefit than mitral valve replacement in the LVD patients.</p

    Quality control and beam test of GEM detectors for future upgrades of the CMS muon high rate region at the LHC

    Get PDF
    Gas Electron Multipliers (GEM) are a proven position sensitive gas detector technology which nowadays is becoming more widely used in High Energy Physics. GEMs offer an excellent spatial resolution and a high particle rate capability, with a close to 100% detection efficiency. In view of the high luminosity phase of the CERN Large Hadron Collider, these aforementioned features make GEMs suitable candidates for the future upgrades of the Compact Muon Solenoid (CMS) detector. In particular, the CMS GEM Collaboration proposes to cover the high-eta region of the muon system with large-area triple-GEM detectors, which have the ability to provide robust and redundant tracking and triggering functions. In this contribution, after a general introduction and overview of the project, the construction of full-size trapezoidal triple-GEM prototypes will be described in more detail. The procedures for the quality control of the GEM foils, including gain uniformity measurements with an x-ray source will be presented. In the past few years, several CMS triple-GEM prototype detectors were operated with test beams at the CERN SPS. The results of these test beam campaigns will be summarised

    l-Tetrahydropalmatine, an Active Component of Corydalis yanhusuo W.T. Wang, Protects against Myocardial Ischaemia-Reperfusion Injury in Rats

    Get PDF
    l-Tetrahydropalmatine (l-THP) is an active ingredients of Corydalis yanhusuo W.T. Wang, which protects against acute global cerebral ischaemia-reperfusion injury. In this study, we show that l-THP is cardioprotective in myocardial ischaemia-reperfusion injury and examined the mechanism. Rats were treated with l-THP (0, 10, 20, 40 mg/kg b.w.) for 20 min before occlusion of the left anterior descending coronary artery and subjected to myocardial ischaemia-reperfusion (30 min/6 h). Compared with vehicle-treated animals, the infarct area/risk area (IA/RA) of l-THP (20, 40 mg/kg b.w.) treated rats was reduced, whilst l-THP (10 mg/kg b.w.) had no significant effect. Cardiac function was improved in l-THP-treated rats whilst plasma creatine kinase activity declined. Following treatment with l-THP (20 mg/kg b.w.), subunit of phosphatidylinositol 3-kinase p85, serine473 phosphorylation of Akt and serine1177 phosphorylation of endothelial NO synthase (eNOS) increased in myocardium, whilst expression of inducible NO synthase (iNOS) decreased. However, the expression of HIF-1Îą and VEGF were increased in I30 minR6 h, but decreased to normal level in I30 minR24 h, while treatment with l-THP (20 mg/kg b.w.) enhanced the levels of these two genes in I30 minR24 h. Production of NO in myocardium and plasma, activity of myeloperoxidase (MPO) in plasma and the expression of tumour necrosis factor-Îą (TNF-Îą) in myocardium were decreased by l-THP. TUNEL assay revealed that l-THP (20 mg/kg b.w.) reduced apoptosis in myocardium. Thus, we show that l-THP activates the PI3K/Akt/eNOS/NO pathway and increases expression of HIF-1Îą and VEGF, whilst depressing iNOS-derived NO production in myocardium. This effect may decrease the accumulation of inflammatory factors, including TNF-Îą and MPO, and lessen the extent of apoptosis, therefore contributing to the cardioprotective effects of l-THP in myocardial ischaemia-reperfusion injury

    Measurement of the t(t)over-bar production cross section in the dilepton channel in pp collisions at √s=8 TeV

    Get PDF
    The top-antitop quark (t (t) over bar) production cross section is measured in proton-proton collisions at root s = 8 TeV with the CMS experiment at the LHC, using a data sample corresponding to an integrated luminosity of 5.3 fb(-1). The measurement is performed by analysing events with a pair of electrons or muons, or one electron and one muon, and at least two jets, one of which is identified as originating from hadronisation of a bottom quark. The measured cross section is 239 +/- 2 (stat.) +/- 11 (syst.) +/- 6 (lum.) pb, for an assumed top-quark mass of 172.5 GeV, in agreement with the prediction of the standard model

    Voltammetric aptasensors for protein disease biomarkers detection: a review

    Get PDF
    "Available online 24 May 2016"An electrochemical aptasensor is a compact analytical device where the bioreceptor (aptamer) is coupled to a transducer surface to convert a biological interaction into a measurable signal (current) that can be easily processed, recorded and displayed. Since the discovery of the Systematic Evolution of Ligands by Enrichment (SELEX) methodology, the selection of aptamers and their application as bioreceptors has become a promising tool in the design of electrochemical aptasensors. Aptamers present several advantages that highlight their usefulness as bioreceptors such as chemical stability, cost effectiveness and ease of modification towards detection and immobilization at different transducer surfaces. In this review, a special emphasis is given to the potential use of electrochemical aptasensors for the detection of protein disease biomarkers using voltammetry techniques. Methods for the immobilization of aptamers onto electrode surfaces are discussed, as well as different electrochemical strategies that can be used for the design of aptasensors.The authors acknowledge the financial support from the Strategic funding of UID/BIO/04469/2013 unit, from Project POCI-01-0145- FEDER-006984 – Associate Laboratory LSRE-LCM funded by FEDER funds through COMPETE2020 - Programa Operacional Competitividade e Internacionalização (POCI) – and by national funds through FCT - Fundação para a Ciência e a Tecnologia and project ref. RECI/BBB-EBI/ 0179/2012 (project number FCOMP-01-0124-FEDER-027462) and S. Meirinhos's doctoral grant (ref SFRH/BD/65021/2009) funded by Fundação para a Ciência e a Tecnologia

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore