4 research outputs found

    Evaluation of volumetric modulated arc therapy and quality assurance based on Monte Carlo simulation

    Get PDF
    Complex intensity modulated fields delivered by means of rotational dynamic techniques, such as Volumetric Modulated Arc Therapy (VMAT), can be considered a step forward in comparison to conventional, static technique, providing demanding dose distributions in short irradiation times. However this dynamic implementation involves two main sources of uncertainty: one related to the dose calculation accuracy, and the other linked to the continuous delivery of a discrete calculation. Therefore, require new quality assurance (QA) protocols and detailed verification capable of predicting the actual delivered dose to the patient. This is especially critical when used with hypofractionated schemes and for stereotactic body radiotherapy (SBRT) treatments. In this scenario, Monte Carlo (MC) simulation presents an ideal tool to complete the linac commissioning required for VMAT, as well as the gold standard for dose distribution verification. The present thesis reflects the work carried out in order to implement a routine MC verification of VMAT treatments, and to develop a QA model able to control and potentially reduce the inherent uncertainties for a fair and reliable evaluation of current VMAT solutions, including further evaluation of VMAT QA systems. The developed model consists on a system composed by a specific phantom integrated with MC simulation of VMAT log files in a feedback procedure by implementing an optimization process able to adjust the Monitor Units and reconstruct the dose-volume histogram on the patient CT. Several clinical cases, previously planned with different treatment planning systems and verified with different commercial solutions were selected in order to test operational feasibility of the proposed model. The proper operation of the feedback procedure was proved through the achieved high agreement between reconstructed dose distributions and the film measurements. The proposed model showed to be valid for VMAT assessment, and also for linac commissioning and evaluation of other QA systems. Besides, the results also showed enough robustness and efficiency of the model to be considered as a pre-treatment VMAT verification system

    Accurate,robust and harmonized implementation of morpho-functional imaging in treatment planning for personalized radiotherapy

    Get PDF
    In this work we present a methodology able to use harmonized PET/CT imaging in dose painting by number (DPBN) approach by means of a robust and accurate treatment planning system. Image processing and treatment planning were performed by using a Matlab-based platform, called CARMEN, in which a full Monte Carlo simulation is included. Linear programming formulation was developed for a voxel-by-voxel robust optimization and a specific direct aperture optimization was designed for an efficient adaptive radiotherapy implementation. DPBN approach with our methodology was tested to reduce the uncertainties associated with both, the absolute value and the relative value of the information in the functional image. For the same H&N case, a single robust treatment was planned for dose prescription maps corresponding to standardized uptake value distributions from two different image reconstruction protocols: One to fulfill EARL accreditation for harmonization of [18F]FDG PET/CT image, and the other one to use the highest available spatial resolution. Also, a robust treatment was planned to fulfill dose prescription maps corresponding to both approaches, the dose painting by contour based on volumes and our voxel-by-voxel DPBN. Adaptive planning was also carried out to check the suitability of our proposal. Different plans showed robustness to cover a range of scenarios for implementation of harmonizing strategies by using the highest available resolution. Also, robustness associated to discretization level of dose prescription according to the use of contours or numbers was achieved. All plans showed excellent quality index histogram and quality factors below 2%. Efficient solution for adaptive radiotherapy based directly on changes in functional image was obtained. We proved that by using voxel-by-voxel DPBN approach it is possible to overcome typical drawbacks linked to PET/CT images, providing to the clinical specialist confidence enough for routinely implementation of functional imaging for personalized radiotherapy.Junta de Andalucía (FISEVI, reference project CTS 2482)European Regional Development Fund (FEDER

    3D VMAT Verification Based on Monte Carlo Log File Simulation with Experimental Feedback from Film Dosimetry.

    Get PDF
    A model based on a specific phantom, called QuAArC, has been designed for the evaluation of planning and verification systems of complex radiotherapy treatments, such as volumetric modulated arc therapy (VMAT). This model uses the high accuracy provided by the Monte Carlo (MC) simulation of log files and allows the experimental feedback from the high spatial resolution of films hosted in QuAArC. This cylindrical phantom was specifically designed to host films rolled at different radial distances able to take into account the entrance fluence and the 3D dose distribution. Ionization chamber measurements are also included in the feedback process for absolute dose considerations. In this way, automated MC simulation of treatment log files is implemented to calculate the actual delivery geometries, while the monitor units are experimentally adjusted to reconstruct the dose-volume histogram (DVH) on the patient CT. Prostate and head and neck clinical cases, previously planned with Monaco and Pinnacle treatment planning systems and verified with two different commercial systems (Delta4 and COMPASS), were selected in order to test operational feasibility of the proposed model. The proper operation of the feedback procedure was proved through the achieved high agreement between reconstructed dose distributions and the film measure- ments (global gamma passing rates > 90% for the 2%/2 mm criteria). The necessary discre- tization level of the log file for dose calculation and the potential mismatching between calculated control points and detection grid in the verification process were discussed. Besides the effect of dose calculation accuracy of the analytic algorithm implemented in treatment planning systems for a dynamic technique, it was discussed the importance of the detection density level and its location in VMAT specific phantom to obtain a more reliable DVH in the patient CT. The proposed model also showed enough robustness and efficiency to be considered as a pre-treatment VMAT verification system.Ministerio de Ciencia y Tecnología SAF2011- 27116; IPT-2011-1480-900000

    Characterisation of microbial attack on archaeological bone

    Get PDF
    As part of an EU funded project to investigate the factors influencing bone preservation in the archaeological record, more than 250 bones from 41 archaeological sites in five countries spanning four climatic regions were studied for diagenetic alteration. Sites were selected to cover a range of environmental conditions and archaeological contexts. Microscopic and physical (mercury intrusion porosimetry) analyses of these bones revealed that the majority (68%) had suffered microbial attack. Furthermore, significant differences were found between animal and human bone in both the state of preservation and the type of microbial attack present. These differences in preservation might result from differences in early taphonomy of the bones. © 2003 Elsevier Science Ltd. All rights reserved
    corecore