638 research outputs found

    Extraordinarily transparent compact metallic metamaterials

    Get PDF
    The design of achromatic optical components requires materials with high transparency and low dispersion. We show that although metals are highly opaque, densely packed arrays of metallic nanoparticles can be more transparent to infrared radiation than dielectrics such as germanium, even when the arrays are over 75% metal by volume. Such arrays form effective dielectrics that are virtually dispersion-free over ultra-broadband ranges of wavelengths from microns up to millimeters or more. Furthermore, the local refractive indices may be tuned by altering the size, shape, and spacing of the nanoparticles, allowing the design of gradient-index lenses that guide and focus light on the microscale. The electric field is also strongly concentrated in the gaps between the metallic nanoparticles, and the simultaneous focusing and squeezing of the electric field produces strong ‘doubly-enhanced’ hotspots which could boost measurements made using infrared spectroscopy and other non-linear processes over a broad range of frequencies

    Bioelectronics-on-a-chip for cardio myoblast proliferation enhancement using electric field stimulation

    Get PDF
    Background: Cardio myoblast generation from conventional approaches is laborious and time-consuming. We present a bioelectronics on-a-chip for stimulating cells cardio myoblast proliferation during culture. Method: The bioelectronics chip fabrication methodology involves two different process. In the first step, an aluminum layer of 200 nm is deposited over a soda-lime glass substrate using physical vapor deposition and selectively removed using a Q-switched Nd:YVO4 laser to create the electric tracks. To perform the experiments, we developed a biochip composed of a cell culture chamber fabricated with polydimethylsiloxane (PDMS) with a glass coverslip or a cell culture dish placed over the electric circuit tracks. By using such a glass cover slip or cell culture dish we avoid any toxic reactions caused by electrodes in the culture or may be degraded by electrochemical reactions with the cell medium, which is crucial to determine the effective cell-device coupling. Results: The chip was used to study the effect of electric field stimulation of Rat ventricular cardiomyoblasts cells (H9c2). Results shows a remarkable increase in the number of H9c2 cells for the stimulated samples, where after 72 h the cell density double the cell density of control samples. Conclusions: Cell proliferation of Rat ventricular cardiomyoblasts cells (H9c2) using the bioelectronics-on-a-chip was enhanced upon the electrical stimulation. The dependence on the geometrical characteristics of the electric circuit on the peak value and homogeneity of the electric field generated are analyzed and proper parameters to ensure a homogeneous electric field at the cell culture chamber are obtained. It can also be observed a high dependence of the electric field on the geometry of the electrostimulator circuit tracks and envisage the potential applications on electrophysiology studies, monitoring and modulate cellular behavior through the application of electric fields

    Caffeine, a Risk Factor for Osteoarthritis and Longitudinal Bone Growth Inhibition

    Get PDF
    Osteoarthritis (OA), the most common chronic rheumatic disease, is mainly characterized by a progressive degradation of the hyaline articular cartilage, which is essential for correct joint function, lubrication, and resistance. Articular cartilage disturbances lead to joint failure, pain, and disability. Hyaline cartilage is also present in the growth plate and plays a key role in longitudinal bone growth. Alterations of this cartilage by diverse pathologies have been related to longitudinal bone growth inhibition (LBGI), which leads to growth retardation. Diet can play a crucial role in processes involved in the OA and LBGI's onset and evolution. Specifically, there is ample evidence pointing to the negative impacts of caffeine consumption on hyaline cartilage. However, its effects on these tissues have not been reviewed. Accordingly, in this review, we summarize all current knowledge in the PubMed database about caffeine catabolic effects on articular and growth plate cartilage. Specifically, we focus on the correlation between OA and LBGI with caffeine prenatal or direct exposure. Overall, there is ample evidence indicating that caffeine intake negatively affects the physiology of both articular and growth plate cartilage, increasing consumers predisposition to suffer OA and LBGI. As a result, caffeine consumption should be avoided for these pathologies

    Nanoinformatics: developing new computing applications for nanomedicine

    Get PDF
    Nanoinformatics has recently emerged to address the need of computing applications at the nano level. In this regard, the authors have participated in various initiatives to identify its concepts, foundations and challenges. While nanomaterials open up the possibility for developing new devices in many industrial and scientific areas, they also offer breakthrough perspectives for the prevention, diagnosis and treatment of diseases. In this paper, we analyze the different aspects of nanoinformatics and suggest five research topics to help catalyze new research and development in the area, particularly focused on nanomedicine. We also encompass the use of informatics to further the biological and clinical applications of basic research in nanoscience and nanotechnology, and the related concept of an extended ?nanotype? to coalesce information related to nanoparticles. We suggest how nanoinformatics could accelerate developments in nanomedicine, similarly to what happened with the Human Genome and other -omics projects, on issues like exchanging modeling and simulation methods and tools, linking toxicity information to clinical and personal databases or developing new approaches for scientific ontologies, among many others

    Commissioning of the LHCb Silicon Tracker using data from the LHC injection tests

    Get PDF
    LHCb is a single-arm forward spectrometer dedicated to the study of the CP-violation and rare decays in the b-quark sector. An efficient and high precision tracking system is a key requirement of the experiment. The LHCb Silicon Tracker Project consists of two sub-detectors that make use of silicon micro-strip technology: the Tracker Turicensis located upstream of the spectrometer magnet and the Inner Tracker which covers the innermost part of the tracking stations after the magnet. In total an area of 12 m^2 is covered by silicon. In September 2008 and June 2009, injection tests from the SPS to the LHC were performed. Bunches of order 5x10^9 protons were dumped onto a beam stopper (TED) located upstream of LHCb. This produced a spray of ~10 GeV muons in the LHCb detector. Though the occupancy in this environment is relatively large, these TED runs have allowed a first space and time alignment of the tracking system. Results of these studies together and the overall detector performance obtained in the TED running will be discussed

    Differential branching fraction and angular analysis of the decay B0→K∗0ÎŒ+Ό−

    Get PDF
    The angular distribution and differential branching fraction of the decay B 0→ K ∗0 ÎŒ + ÎŒ − are studied using a data sample, collected by the LHCb experiment in pp collisions at s√=7 TeV, corresponding to an integrated luminosity of 1.0 fb−1. Several angular observables are measured in bins of the dimuon invariant mass squared, q 2. A first measurement of the zero-crossing point of the forward-backward asymmetry of the dimuon system is also presented. The zero-crossing point is measured to be q20=4.9±0.9GeV2/c4 , where the uncertainty is the sum of statistical and systematic uncertainties. The results are consistent with the Standard Model predictions

    Observation of associated production of a ZZ boson with a DD meson in the~forward region

    Get PDF
    A search for associated production of a ZZ boson with an open charm meson is presented using a data sample, corresponding to an integrated luminosity of 1.0 fb−‘1.0\,\mathrm{fb}^{-`} of proton--proton collisions at a centre-of-mass energy of 7\,TeV, collected by the LHCb experiment. %% Seven candidate events for associated production of a ZZ boson with a D0D^0 meson and four candidate events for a ZZ boson with a D+D^+ meson are observed with a combined significance of 5.1standard deviations. The production cross-sections in the forward region are measured to be σZ→Ό+ÎŒâˆ’â€‰âŁ,D0=2.50±1.12±0.22pb\sigma_{Z\rightarrow\mu^+\mu^-\!,D^0} = 2.50\pm1.12\pm0.22pb σZ→Ό+ÎŒâˆ’â€‰âŁ,D+=0.44±0.23±0.03pb,\sigma_{Z\rightarrow\mu^+\mu^-\!,D^+} = 0.44\pm0.23\pm0.03pb, where the first uncertainty is statistical and the second systematic.Comment: 18 pages, 2 figure

    Measurement of the relative rate of prompt χc0, χc1 and χc2 production at √s=7TeV

    Get PDF
    Prompt production of charmonium χc0, χc1 and χc2 mesons is studied using proton-proton collisions at the LHC at a centre-of-mass energy of √s=7TeV. The χc mesons are identified through their decay to J/ÏˆÎł, with J/ψ→Ό+mu− using photons that converted in the detector. A data sample, corresponding to an integrated luminosity of 1.0fb−1 collected by the LHCb detector, is used to measure the relative prompt production rate of χc1 and χc2 in the rapidity range 2.0<y<4.5 as a function of the J/ψ transverse momentum from 3 to 20 GeV/c. First evidence for χc0 meson production at a hadron collider is also presented

    Measurements of the B+B^+, B0B^0, Bs0B_s^0 meson and Λb0\Lambda_b^0 baryon lifetimes

    Get PDF
    Measurements of bb-hadron lifetimes are reported using pppp collision data, corresponding to an integrated luminosity of 1.0fb−1^{-1}, collected by the LHCb detector at a centre-of-mass energy of 77Tev. Using the exclusive decays B+→J/ψK+B^+\to J/\psi K^+, B0→J/ψK∗(892)0B^0\to J/\psi K^*(892)^0, B0→J/ψKS0B^0\to J/\psi K^0_{\rm S}, Λb0→J/ψΛ\Lambda_b^0\to J/\psi \Lambda and Bs0→J/ψϕB^0_s\to J/\psi \phi the average decay times in these modes are measured to be τB+→J/ψK+\tau_{B^+\to J/\psi K^+} = 1.637±1.637 \pm 0.004 ±\pm 0.003 ps, τB0→J/ψK∗(892)0\tau_{B^0\to J/\psi K^*(892)^0} = 1.524±1.524 \pm 0.006 ±\pm 0.004 ps, τB0→J/ψKS0\tau_{B^0\to J/\psi K^0_{\rm S}} = 1.499±1.499 \pm 0.013 ±\pm 0.005 ps, τΛb0→J/ψΛ\tau_{\Lambda_b^0\to J/\psi \Lambda} = 1.415±1.415 \pm 0.027 ±\pm 0.006 ps and τBs0→J/ψϕ\tau_{B^0_s\to J/\psi \phi} = 1.480±1.480 \pm 0.011 ±\pm 0.005 ps, where the first uncertainty is statistical and the second is systematic. These represent the most precise lifetime measurements in these decay modes. In addition, ratios of these lifetimes, and the ratio of the decay-width difference, ΔΓd\Delta\Gamma_d, to the average width, Γd\Gamma_d, in the B0B^0 system, ΔΓd/Γd=−0.044±0.025±0.011\Delta \Gamma_d/\Gamma_d = -0.044 \pm 0.025 \pm 0.011, are reported. All quantities are found to be consistent with Standard Model expectations.Comment: 28 pages, 4 figures. Updated reference
    • 

    corecore