10 research outputs found

    Towards a realistic in vitro experience of epidural Tuohy needle insertion.

    Get PDF
    The amount of pressure exerted on the syringe and the depth of needle insertion are the two key factors for successfully carrying out epidural procedure. The force feedback from the syringe plunger is helpful in judging the loss of pressure, and the depth of the needle insertion is crucial in identifying when the needle is precisely placed in the epidural space. This article presents the development of two novel wireless devices to measure these parameters to precisely guide the needle placement in the epidural space. These techniques can be directly used on patients or implemented in a simulator for improving the safety of procedure. A pilot trial has been conducted to collect depth and pressure data with the devices on a porcine cadaver. These measurements are then combined to accurately configure a haptic device for creating a realistic in vitro experience of epidural needle insertion

    A review of epidural simulators: Where are we today?

    Get PDF
    Thirty-one central neural blockade simulators have been implemented into clinical practice over the last thirty years either commercially or for research. This review aims to provide a detailed evaluation of why we need epidural and spinal simulators in the first instance and then draws comparisons between computer-based and manikin-based simulators. This review covers thirty-one simulators in total; sixteen of which are solely epidural simulators, nine are for epidural plus spinal or lumbar puncture simulation, and six, which are solely lumbar puncture simulators. All hardware and software components of simulators are discussed, including actuators, sensors, graphics, haptics, and virtual reality based simulators. The purpose of this comparative review is to identify the direction for future epidural simulation by outlining necessary improvements to create the ideal epidural simulator. The weaknesses of existing simulators are discussed and their strengths identified so that these can be carried forward. This review aims to provide a foundation for the future creation of advanced simulators to enhance the training of epiduralists, enabling them to comprehensively practice epidural insertion in vitro before training on patients and ultimately reducing the potential risk of harm. © 2013 IPEM

    If I had a Hammer

    No full text

    A case of lung volume reduction surgery with decortication for a septic patient in respiratory failure

    Get PDF
    Introduction: Decortication and lung volume reduction surgery are both major operations and each has its independent risk of morbidity and mortality. Case report: We present the case of a 41 year old gentleman with left sided empyema and giant bullae of the upper lobe with an active air leak that was transferred to our tertiary referral centre for further management. We performed emergency left thoracotomy, decorticated the left lower lobe with extensive lung volume reduction surgery of the upper lobe. Patient’s respiratory status significantly improved along with excellent radiological results. Conclusion: Our case demonstrates that a combination of complex procedures is feasible with excellent outcomes

    Perioperative diagnostics of patients referred for radioiodine therapy of differentiated thyroid carcinoma: referral center experience in an iodine-insufficient country

    Get PDF
    PURPOSE: The interdisciplinary “Martinique-Principles” of four international professional societies concerned with the patient management of differentiated thyroid cancer (DTC) patients were agreed upon. Differences in perioperative diagnostics can lead to differences in clinical decision founding regarding the treatment of thyroid carcinoma. Our aim was to analyze the perioperative diagnostics of patients referred for postoperative I-131 therapy of DTC. METHODS: We retrospectively examined the data of 142 patients who were referred to our center for the first course of postsurgical I-131 therapy. We extracted data on perioperative diagnostics. RESULTS: Fine-needle biopsy (FNB) was performed in 27/142 patients. In 17 patients, FNB yielded findings suspicious of malignancy, in 3 patients a follicular lesion was reported. An intraoperative frozen section analysis was performed in 79/142 patients. 5/63 patients showed already a cytologically proven malignancy. In 10/79 patients, the frozen section had a nonmalignant result, although DTC was found on final assessment. In 2/79 patients, frozen section analysis was indecisive, although the final report confirmed DTC. In the remaining 67 patients, frozen section yielded DTC. CONCLUSIONS: There is room for improvement in perioperative diagnostics surrounding thyroid surgery, currently many procedures are performed without adequate information on potential presence of thyroid cancer. More frequent use of FNB might be able to decrease the number of unnecessary thyroid surgeries, increased use of frozen section might decrease the number of second operations and might contribute to less discordance between experts in the field of DTC treatment

    ImaGiNe Seldinger : first simulator for Seldinger technique and angiography training

    Get PDF
    In vascular interventional radiology, procedures generally start with the Seldinger technique to access the vasculature, using a needle through which a guidewire is inserted, followed by navigation of catheters within the vessels. Visual and tactile skills are learnt in a patient apprenticeship which is expensive and risky for patients. We propose a training alternative through a new virtual simulator supporting the Seldinger technique: ImaGiNe (imaging guided interventional needle) Seldinger. It is composed of two workstations: (1) a simulated pulse is palpated, in an immersive environment, to guide needle puncture and (2) two haptic devices provide a novel interface where a needle can direct a guidewire and catheter within the vessel lumen, using virtual fluoroscopy. Different complexities are provided by 28 real patient datasets. The feel of the simulation is enhanced by replicating, with the haptics, real force and flexibility measurements. A preliminary validation study has demonstrated training effectiveness for skills transfer
    corecore