452 research outputs found
Design and experimental characterization of a tunable vibration-based electromagnetic micro-generator
Vibration-based micro-generators, as an alternative source of energy, have become increasingly significant in the last decade. This paper presents a new tunable electromagnetic vibration-based micro-generator. Frequency tuning is realized by applying an axial tensile force to the micro-generator. The dimensions of the generator, especially the dimensions of the coil and the air gap between magnets, have been optimized to maximize the output voltage and power of the micro-generator. The resonant frequency has been successfully tuned from 67.6 to 98 Hz when various axial tensile forces were applied to the structure. The generator produced a power of 61.6–156.6 µW over the tuning range when excited at vibrations of 0.59 ms-2. The tuning mechanism has little effect on the total damping. When the tuning force applied on the generator becomes larger than the generator’s inertial force, the total damping increases resulting in reduced output power. The resonant frequency increases less than indicated from simulation and approaches that of a straight tensioned cable when the force associated with the tension in the beam becomes much greater than the beam stiffness. The test results agree with the theoretical analysis presented
Integrating the promotion of physical activity within a smoking cessation programme: Findings from collaborative action research in UK Stop Smoking Services
Background: Within the framework of collaborative action research, the aim was to explore the feasibility of
developing and embedding physical activity promotion as a smoking cessation aid within UK 6/7-week National
Health Service (NHS) Stop Smoking Services.
Methods: In Phase 1 three initial cycles of collaborative action research (observation, reflection, planning,
implementation and re-evaluation), in an urban Stop Smoking Service, led to the development of an integrated
intervention in which physical activity was promoted as a cessation aid, with the support of a theoretically based
self-help guide, and self monitoring using pedometers. In Phase 2 advisors underwent training and offered the
intervention, and changes in physical activity promoting behaviour and beliefs were monitored. Also, changes in
clients’ stage of readiness to use physical activity as a cessation aid, physical activity beliefs and behaviour and
physical activity levels were assessed, among those who attended the clinic at 4-week post-quit. Qualitative data
were collected, in the form of clinic observation, informal interviews with advisors and field notes.
Results: The integrated intervention emerged through cycles of collaboration as something quite different to
previous practice. Based on field notes, there were many positive elements associated with the integrated
intervention in Phase 2. Self-reported advisors’ physical activity promoting behaviour increased as a result of
training and adapting to the intervention. There was a significant advancement in clients’ stage of readiness to use physical activity as a smoking cessation aid.
Conclusions: Collaboration with advisors was key in ensuring that a feasible intervention was developed as an aid to smoking cessation. There is scope to further develop tailored support to increasing physical activity and
smoking cessation, mediated through changes in perceptions about the benefits of, and confidence to do physical activity
Walk well:a randomised controlled trial of a walking intervention for adults with intellectual disabilities: study protocol
Background - Walking interventions have been shown to have a positive impact on physical activity (PA) levels, health and wellbeing for adult and older adult populations. There has been very little work carried out to explore the effectiveness of walking interventions for adults with intellectual disabilities. This paper will provide details of the Walk Well intervention, designed for adults with intellectual disabilities, and a randomised controlled trial (RCT) to test its effectiveness. Methods/design - This study will adopt a RCT design, with participants allocated to the walking intervention group or a waiting list control group. The intervention consists of three PA consultations (baseline, six weeks and 12 weeks) and an individualised 12 week walking programme. A range of measures will be completed by participants at baseline, post intervention (three months from baseline) and at follow up (three months post intervention and six months from baseline). All outcome measures will be collected by a researcher who will be blinded to the study groups. The primary outcome will be steps walked per day, measured using accelerometers. Secondary outcome measures will include time spent in PA per day (across various intensity levels), time spent in sedentary behaviour per day, quality of life, self-efficacy and anthropometric measures to monitor weight change. Discussion - Since there are currently no published RCTs of walking interventions for adults with intellectual disabilities, this RCT will examine if a walking intervention can successfully increase PA, health and wellbeing of adults with intellectual disabilities
Live cell tracking of macrophage efferocytosis during Drosophila embryo development in vivo
Apoptosis of cells and their subsequent removal via efferocytosis occurs in nearly all tissues during development, homeostasis, and disease. However, it has been difficult to track cell death and subsequent corpse removal in vivo. Here, we developed a genetically encoded fluorescent reporter, CharON, that could track emerging apoptotic cells and their efferocytic clearance by phagocytes. Using Drosophila expressing CharON, we uncovered multiple qualitative and quantitative features of coordinated clearance of apoptotic corpses during embryonic development. To confront high rate of emerging apoptotic corpses, the macrophages displayed heterogeneity in engulfment, with some efferocytic macrophages carrying high corpse burden. However, overburdened macrophages were compromised in clearing wound debris, revealing an inherent vulnerability. These findings reveal known and unexpected features of apoptosis and macrophage efferocytosis in vivo
Formation of Long-Lived Color Centers for Broadband Visible Light Emission in Low-Dimensional Layered Perovskites.
We investigate the origin of the broadband visible emission in layered hybrid lead-halide perovskites and its connection with structural and photophysical properties. We study ⟨001⟩ oriented thin films of hexylammonium (HA) lead iodide, (C6H16N)2PbI4, and dodecylammonium (DA) lead iodide, (C12H28N)2PbI4, by combining first-principles simulations with time-resolved photoluminescence, steady-state absorption and X-ray diffraction measurements on cooling from 300 to 4 K. Ultrafast transient absorption and photoluminescence measurements are used to track the formation and recombination of emissive states. In addition to the excitonic photoluminescence near the absorption edge, we find a red-shifted, broadband (full-width at half-maximum of about 0.4 eV), emission band below 200 K, similar to emission from ⟨110⟩ oriented bromide 2D perovskites at room temperature. The lifetime of this sub-band-gap emission exceeds that of the excitonic transition by orders of magnitude. We use X-ray diffraction measurements to study the changes in crystal lattice with temperature. We report changes in the octahedral tilt and lattice spacing in both materials, together with a phase change around 200 K in DA2PbI4. DFT simulations of the HA2PbI4 crystal structure indicate that the low-energy emission is due to interstitial iodide and related Frenkel defects. Our results demonstrate that white-light emission is not limited to ⟨110⟩ oriented bromide 2D perovskites but a general property of this class of system, and highlight the importance of defect control for the formation of low-energy emissive sites, which can provide a pathway to design tailored white-light emitters
Recommended from our members
Contralateral Hemispheric Cerebral Blood Flow Measured With Arterial Spin Labeling Can Predict Outcome in Acute Stroke.
Background and Purpose- Imaging is frequently used to select acute stroke patients for intra-arterial therapy. Quantitative cerebral blood flow can be measured noninvasively with arterial spin labeling magnetic resonance imaging. Cerebral blood flow levels in the contralateral (unaffected) hemisphere may affect capacity for collateral flow and patient outcome. The goal of this study was to determine whether higher contralateral cerebral blood flow (cCBF) in acute stroke identifies patients with better 90-day functional outcome. Methods- Patients were part of the prospective, multicenter iCAS study (Imaging Collaterals in Acute Stroke) between 2013 and 2017. Consecutive patients were enrolled after being diagnosed with anterior circulation acute ischemic stroke. Inclusion criteria were ischemic anterior circulation stroke, baseline National Institutes of Health Stroke Scale score ≥1, prestroke modified Rankin Scale score ≤2, onset-to-imaging time <24 hours, with imaging including diffusion-weighted imaging and arterial spin labeling. Patients were dichotomized into high and low cCBF groups based on median cCBF. Outcomes were assessed by day-1 and day-5 National Institutes of Health Stroke Scale; and day-30 and day-90 modified Rankin Scale. Multivariable logistic regression was used to test whether cCBF predicted good neurological outcome (modified Rankin Scale score, 0-2) at 90 days. Results- Seventy-seven patients (41 women) met the inclusion criteria with median (interquartile range) age of 66 (55-76) yrs, onset-to-imaging time of 4.8 (3.6-7.7) hours, and baseline National Institutes of Health Stroke Scale score of 13 (9-20). Median cCBF was 38.9 (31.2-44.5) mL per 100 g/min. Higher cCBF predicted good outcome at day 90 (odds ratio, 4.6 [95% CI, 1.4-14.7]; P=0.01), after controlling for baseline National Institutes of Health Stroke Scale, diffusion-weighted imaging lesion volume, and intra-arterial therapy. Conclusions- Higher quantitative cCBF at baseline is a significant predictor of good neurological outcome at day 90. cCBF levels may inform decisions regarding stroke triage, treatment of acute stroke, and general outcome prognosis. Clinical Trial Registration- URL: https://www.clinicaltrials.gov. Unique identifier: NCT02225730
Step based physical activity guidelines for preschool-aged children
OBJECTIVE Public health organizations recommend that preschool-aged children accumulate at least 3h of physical activity (PA) daily. Objective monitoring using pedometers offers an opportunity to measure preschooler's PA and assess compliance with this recommendation. The purpose of this study was to derive step-based recommendations consistent with the 3h PA recommendation for preschool-aged children. METHOD The study sample comprised 916 preschool-aged children, aged 3 to 6years (mean age=5.0+/-0.8years). Children were recruited from kindergartens located in Portugal, between 2009 and 2013. Children wore an ActiGraph GT1M accelerometer that measured PA intensity and steps per day simultaneously over a 7-day monitoring period. Receiver operating characteristic (ROC) curve analysis was used to identify the daily step count threshold associated with meeting the daily 3hour PA recommendation. RESULTS A significant correlation was observed between minutes of total PA and steps per day (r=0.76, p/=3h of total PA was 9099 steps per day (sensitivity (90%) and specificity (66%)) with area under the ROC curve=0.86 (95% CI: 0.84 to 0.88). CONCLUSION Preschool-aged children who accumulate less than 9000 steps per day may be considered Insufficiently Active
Step-based physical activity metrics and cardiometabolic risk: NHANES 2005-2006
Purpose: This study aimed to catalog the relationships between step-based accelerometer metrics indicative of physical activity volume (steps per day, adjusted to a pedometer scale), intensity (mean steps per minute from the highest, not necessarily consecutive, minutes in a day; peak 30-min cadence), and sedentary behavior (percent time at zero cadence relative to wear time; %TZC) and cardiometabolic risk factors. Methods: We analyzed data from 3388 participants, 20+ yr old, in the 2005-2006 National Health and Nutrition Examination Survey with >/=1 valid day of accelerometer data and at least some data on weight, body mass index, waist circumference, systolic and diastolic blood pressure, glucose, insulin, HDL cholesterol, triglycerides, and/or glycohemoglobin. Linear trends were evaluated for cardiometabolic variables, adjusted for age and race, across quintiles of steps per day, peak 30-min cadence, and %TZC. Results: Median steps per day ranged from 2247 to 12,334 steps per day for men and from 1755 to 9824 steps per day for women, and median peak 30-min cadence ranged from 48.1 to 96.0 steps per minute for men and from 40.8 to 96.2 steps per minute for women for the first and fifth quintiles, respectively. Linear trends were statistically significant (all P < 0.001), with increasing quintiles of steps per day and peak 30-min cadence inversely associated with waist circumference, weight, body mass index, and insulin for both men and women. Median %TZC ranged from 17.6% to 51.0% for men and from 19.9% to 47.6% for women for the first and fifth quintiles, respectively. Linear trends were statistically significant (all P < 0.05), with increasing quintiles of %TZC associated with increased waist circumference, weight and insulin for men, and insulin for women. Conclusions: This analysis identified strong linear relationships between step-based movement/nonmovement dimensions and cardiometabolic risk factors. These data offer a set of quantified access points for studying the potential dose-response effects of each of these dimensions separately or collectively in longitudinal observational or intervention study designs.Peer reviewedCommunity Health Sciences, Counseling and Counseling Psycholog
Physical activity monitoring: Addressing the difficulties of accurately detecting slow walking speeds
OBJECTIVE: To test the accuracy of a multi-sensor activity monitor (SWM) in detecting slow walking speeds in patients with chronic obstructive pulmonary disease (COPD). BACKGROUND: Concerns have been expressed regarding the use of pedometers in patient populations. Although activity monitors are more sophisticated devices, their accuracy at detecting slow walking speeds common in patients with COPD has yet to be proven. METHODS: A prospective observational study design was employed. An incremental shuttle walk test (ISWT) was completed by 57 patients with COPD wearing an SWM. The ISWT was repeated by 20 patients wearing the same SWM. RESULTS: Differences were identified between metabolic equivalents (METS) and between step-count across five levels of the ISWT (p < 0.001). Good within monitor reproducibility between two ISWT was identified for total energy expenditure and step-count (p < 0.001). CONCLUSIONS: The SWM is able to detect slow (standardized) speeds of walking and is an acceptable method for measuring physical activity in individuals disabled by COPD
- …