66 research outputs found
Long-term Running Experience with the Silicon Micro-strip Tracker at the D{\O} detector
The SiliconMicro-strip Tracker (SMT) at the D{\O} experiment in the Fermilab
Tevatron collider has been operating since 2001. In 2006, an additional layer,
referred to as 'Layer 0', was installed to improve impact parameter resolution
and compensate for detector degradation due to radiation damage to the original
innermost SMT layer. The SMT detector provides valuable tracking and vertexing
information for the experiment. This contribution will highlight aspects of the
long term operation of the SMT, including the impact of the silicon readout
test-stand. Due to the full integration of the test-stand into the D{\O}
trigger framework, this test-stand provides an advantageous tool for training
of new experts and studying subtle effects in the SMT while minimizing impact
on the global data acquisition.Comment: Proceedings of TIPP 2011 (Technology and Instrumentation for Particle
Physics 2011), June 9-14 2011, Chicago, US
Recommended from our members
Procedure to determine the two channel timing measurement accuracy and precision of a digital oscilloscope
The digital oscilloscope allows one to make numerous timing measurements, but just how good are those measurements? This document describes a procedure which can be used to determine the accuracy and precision to which a digital oscilloscope can make various two channel timing measurements
Electrical Properties of Carbon Fiber Support Systems
Carbon fiber support structures have become common elements of detector
designs for high energy physics experiments. Carbon fiber has many mechanical
advantages but it is also characterized by high conductivity, particularly at
high frequency, with associated design issues. This paper discusses the
elements required for sound electrical performance of silicon detectors
employing carbon fiber support elements. Tests on carbon fiber structures are
presented indicating that carbon fiber must be regarded as a conductor for the
frequency region of 10 to 100 MHz. The general principles of grounding
configurations involving carbon fiber structures will be discussed. To
illustrate the design requirements, measurements performed with a silicon
detector on a carbon fiber support structure at small radius are presented. A
grounding scheme employing copper-kapton mesh circuits is described and shown
to provide adequate and robust detector performance.Comment: 20 pages, 11 figures, submitted to NI
Bioaccumulation and Biomagnification of Mercury and Methylmercury in Four Sympatric Coastal Sharks in a Protected Subtropical Lagoon
Mercury bioaccumulation is frequently observed in marine ecosystems, often with stronger effects at higher trophic levels. We compared total mercury (THg) and methylmercury (MeHg) from muscle with length, comparative isotopic niche, and diet (via δ13C and δ15N) among four sympatric coastal sharks in Florida Bay (USA): blacknose, blacktip, bull, and lemon. Mercury in blacknose and blacktip sharks increased significantly with size, whereas bull and lemon sharks had a high variance in mercury relative to size. Both δ13C and δ15N were consistent with general resource use and trophic position relationships across all species. A significant relationship was observed between δ13C and mercury in blacktip sharks, suggesting an ontogenetic shift isotopic niche, possibly a dietary change. Multiple regression showed that δ13C and δ15N were the strongest factors regarding mercury bioaccumulation in individuals across all species. Additional research is recommended to resolve the mechanisms that determine mercury biomagnification in individual shark species
Recommended from our members
The design of a hardware testing system for the D Zero Detector
Testing a system as large as the D Zero data acquisition system is difficult. This paper describes the use of IBM compatible personal computers in a hardware test system that can run on any size system from an engineer's test bench to the entire subsystem in the D Zero Detector. The test system uses a PC to VME bus interface for the local testing and the Token Ring network for more global testing. This system has been implemented for several different hardware systems in D Zero
Effect of Progression From Impaired Glucose Tolerance to Diabetes on Cardiovascular Risk Factors and Its Amelioration by Lifestyle and Metformin Intervention: The Diabetes Prevention Program randomized trial by the Diabetes Prevention Program Research Group*
OBJECTIVE Although subjects with diabetes have increased risk for cardiovascular disease (CVD), the evolution of this increased risk as pre-diabetic individuals progress to diabetes is not understood. This study examines the longitudinal relationship between selected CVD risk factors (blood pressure, triglycerides, HDL and LDL cholesterol, and LDL peak particle density [PPD]) and glycemia in the three treatment groups of the Diabetes Prevention Program. RESEARCH DESIGN AND METHODS A total of 3,234 participants with impaired glucose tolerance (IGT) were followed for a mean of 3.2 years after randomization to intensive lifestyle intervention (ILS), metformin, or placebo. Using repeated-measures models, adjusted mean levels of risk factors were estimated for an annual change in glycemic status. Tests were also conducted to assess the risk factor trends with improvement or worsening of glycemic status. RESULTS CVD risk factor values and changes from baseline became more unfavorable as glucose tolerance status deteriorated but improved with reversion to normal glucose tolerance (NGT), especially in the ILS intervention group (trend test P < 0.001 for all risk factors except for LDL PPD [P = 0.02] in ILS and HDL cholesterol [P = 0.02] in placebo). Although there were few significant differences in the transition from IGT to diabetes, there were strong relationships between risk factors and continuous measures of glycemia. CONCLUSIONS Progression from IGT to diabetes is associated with mild deterioration, whereas reversion to NGT is associated with improvement in risk factors. Early intervention with ILS, but less so with metformin, in participants at high risk for diabetes improves the cardiovascular risk and glucose tolerance profile simultaneously
The Layer 0 Inner Silicon Detector of the D0 Experiment
This paper describes the design, fabrication, installation and performance of
the new inner layer called Layer 0 (L0) that was inserted in the existing Run
IIa Silicon Micro-Strip Tracker (SMT) of the D0 experiment at the Fermilab
Tevatron collider. L0 provides tracking information from two layers of sensors,
which are mounted with center lines at a radial distance of 16.1 mm and 17.6 mm
respectively from the beam axis. The sensors and readout electronics are
mounted on a specially designed and fabricated carbon fiber structure that
includes cooling for sensor and readout electronics. The structure has a thin
polyimide circuit bonded to it so that the circuit couples electrically to the
carbon fiber allowing the support structure to be used both for detector
grounding and a low impedance connection between the remotely mounted hybrids
and the sensors.Comment: 28 pages, 9 figure
Test beam performance measurements for the Phase I upgrade of the CMS pixel detector
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is (99.95 ± 0.05) %, while the intrinsic spatial resolutions are (4.80 ± 0.25) μm and (7.99 ± 0.21) μm along the 100 μm and 150 μm pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.Peer reviewe
Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to neq/cm. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations
Mechanical stability of the CMS strip tracker measured with a laser alignment system
Peer reviewe
- …