73 research outputs found

    Continuous wave optical parametric oscillator for quartz-enhanced photoacoustic trace gas sensing

    Get PDF
    A continuous wave optical parametric oscillator, generating up to 300 mW idler output in the 3–4 μm wavelength region, and pumped by a fiber-amplified DBR diode laser is used for trace gas detection by means of quartz-enhanced photoacoustic spectroscopy (QEPAS). Mode-hop-free tuning of the OPO output over 5.2 cm-1 and continuous spectral coverage exceeding 16.5 cm-1 were achieved via electronic pump source tuning alone. Online monitoring of the idler wavelength, with feedback to the DBR diode laser, provided an automated closed-loop control allowing arbitrary idler wavelength selection within the pump tuning range and locking of the idler wavelength with a stability of 1.7×10-3 cm-1 over at least 30 min.\ud \ud Using this approach, we locked the idler wavelength at an ethane absorption peak and obtained QEPAS data to verify the linear response of the QEPAS signal at different ethane concentrations (100 ppbv-20 ppmv) and different power levels. The detection limit for ethane was determined to be 13 ppbv (20 s averaging), corresponding to a normalized noise equivalent absorption coefficient of 4.4×10-7 cm-1  W/Hz1/2

    Apparatus for a Search for T-violating Muon Polarization in Stopped-Kaon Decays

    Full text link
    The detector built at KEK to search for T-violating transverse muon polarization in K+ --> pi0 mu+ nu (Kmu3) decay of stopped kaons is described. Sensitivity to the transverse polarization component is obtained from reconstruction of the decay plane by tracking the mu+ through a toroidal spectrometer and detecting the pi0 in a segmented CsI(Tl) photon calorimeter. The muon polarization was obtained from the decay positron asymmetry of muons stopped in a polarimeter. The detector included features which minimized systematic errors while maintaining high acceptance.Comment: 56 pages, 30 figures, submitted to NI

    A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies

    Anticoagulation and the Elderly Head Trauma Patient

    No full text

    Synthesis of low molecular weight thiols in response to Cd exposure in Thlaspi caerulescens

    No full text
    In this study, we investigated the accumulation of phytochelatins (PCs) and other low molecular weight (LMW) thiols in response to Cd exposure in two contrasting ecotypes differing in Cd accumulation. Using a root elongation test, we found that the highly accumulating ecotype Ganges was more tolerant to Cd than the low Cd-accumulation ecotype Prayon.L-buthionine-(S,R)-sulphoximine (BSO), a potent inhibitor of the gamma-glutamylcysteine synthetase (gamma-ECS) (an enzyme involved in the PC biosynthetic pathway), increased the Cd sensitivity of Prayon, but had no effect on Ganges. Although PC accumulation increased in response to Cd exposure, no significant differences were observed between the two ecotypes. Cd exposure induced a dose-dependent accumulation of both Cys and a still unidentified LMW thiol in roots of both ecotypes. Root accumulation of Cys and this thiol was higher in Ganges than in Prayon; the ecotypic differences were more pronounced when the plants were treated with BSO. These findings suggest that PCs do not contribute to the Cd hypertolerance displayed by the Ganges ecotype of Thlaspi caerulescens, whereas Cys and other LMW thiols might be involved
    • …
    corecore