1,528 research outputs found
3-D X-Ray Computed Tomography
Though well established in medicine as a technique of inspection, x-ray computed tomography (CT) is just beginning to have an impact on nondestructive evaluation. A recent review [1] emphasizes the potential of the technology. An aspect which is apparent from the description of most current systems is that they are being applied to inspection of objects which tend to be locally uniform in the axial direction, e.g., electrical and telephone poles, trees, and rocket motors. The CT systems used are basically adaptations of medical CT technology, and reconstruct slices of an object one at a time. Under the hypothesis that single- or few-slice CT examination will not suffice for certain NDE problems, we have been developing a tomographic system which performs direct three-dimensional reconstruction, in the sense that the transaxial slice is not the fundamental unit of reconstruction. This is accomplished by collecting a set of 2D projection images and performing a reconstruction directly into a 3D array, using an algorithm developed for the purpose. The result differs from a set of spaced conventional slices primarily in the respect that our spatial resolution in the axial direction is substantially as good as that in transaxial planes. Our developmental system is currently limited by beam energy and physical size to examination of small objects; because of its scale it has better absolute resolution (approx. 0.1 mm) than is generally found in CT equipment. The principles employed are quite general and, given appropriately energetic radiation and a 2D array of detectors, could be applied to the inspection of much larger objects. The system will be described, and example reconstructions will be used to illustrate salient aspects of the methodology
Development of an Advanced 3D Cone Beam Tomographic System
While 2D x-ray CT is now commonly used for NDT applications, the interest in 3D x-ray cone beam tomography has significantly increased over the last few years [1,2]. The need to reduce acquisition time for industrial applications, or radiation dose to patients for medical applications, led engineers to develop a new type of tomograph using x-ray beams more efficiently. Thanks to a high spatial resolution, the 3D x-ray CT allows greater knowledge of the object structure. This understanding is necessary to study and improve industrial production of high technology materials. Therefore, 3D x-ray CT is well suited for the study of materials with structural anomalies, such as technical ceramics [2]
X-Ray Cone Beam Tomography with Two Tilted Circular Trajectories
Recently 3-D cone-beam tomography has become of interest for the nondestructive evaluation of advanced materials. The main field of application in nondestructive testing is the evaluation of structural ceramics. Study of such materials implies high density resolution and high sensitivity to cracks. In fact, with a single circular source trajectory, when the cone-beam aperture increases, density is underestimated and cone shaped artifacts may appear at interfaces in the sample even at relatively small aperture [1–3]. These artifacts limit the thickness we can examine with a planar source trajectory. To maintain optimal reconstruction accuracy with a circular source trajectory, the angular aperture must remain within ±10°. However Kudo and Saito [4] showed that this limit can be slightly overcome by using a special interpolation of the shadow area. But to examine greater thicknesses and to maintain resolution, we must widen the cone-beam aperture thereby decreasing accuracy. To overcome these aperture limitations, Tuy [5] introduced the double circular source trajectory idea
Optimization of Parameters for High-Resolution X-Ray Computed Tomography
In recent years there have been efforts to increase the amount of structural information available in x-ray computed tomography (CT) images. These efforts have proceeded in several directions: increasing the number of resolution elements within a given imaging field; increasing the size of the imaging field for a given resolution element size; and decreasing the imaging field with the number of resolution elements held fixed or increased. This paper will discuss problems common to all of these approaches, with examples referred to two specific CT systems designed for 0.05-mm resolution over a 5-cm field and 2-mm resolution over a 2-meter field. The first problem is that of achieving the desired spatial resolution; the solution is application-dependent and must be discussed individually for each case. The second problem is that of achieving acceptable image noise levels.</p
Reinforcing the role of the conventional C-arm - a novel method for simplified distal interlocking
<p>Abstract</p> <p>Background</p> <p>The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR) like setting on human cadaveric lower legs in terms of operating time and radiation exposure.</p> <p>Methods</p> <p>The proposed concept (guided freehand), generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required.</p> <p>Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland). The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests.</p> <p>Results</p> <p>A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4) (mean ± SD) compared to the freehand technique (17.6 ± 10.3) (<it>p </it>< 0.001). Total radiation time (all 4 screws) was 55% lower for the guided freehand technique compared to conventional freehand (<it>p </it>= 0.001). Operating time per screw (from first shot to screw tightened) was on average 22% reduced by guided freehand (<it>p </it>= 0.018).</p> <p>Conclusions</p> <p>In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses.</p
Multimodality Imaging of Abnormal Vascular Perfusion and Morphology in Preclinical 9L Gliosarcoma Model
This study demonstrates that a dynamic susceptibility contrast-magnetic resonance imaging (DSC-MRI) perfusion parameter may indicate vascular abnormality in a brain tumor model and reflects an effect of dexamethasone treatment. In addition, X-ray computed tomography (CT) measurements of vascular tortuosity and tissue markers of vascular morphology were performed to investigate the underpinnings of tumor response to dexamethasone.One cohort of Fisher 344 rats (N = 13), inoculated intracerebrally with 9L gliosarcoma cells, was treated with dexamethasone (i.p. 3 mg/kg/day) for five consecutive days, and another cohort (N = 11) was treated with equal volume of saline. Longitudinal DSC-MRI studies were performed at the first (baseline), third and fifth day of treatments. Relative cerebral blood volume (rCBV) was significantly reduced on the third day of dexamethasone treatment (0.65 ± .13) as compared to the fifth day during treatment (1.26 ±.19, p < 0.05). In saline treated rats, relative CBV gradually increased during treatment (0.89 ±.13, 1.00 ± .21, 1.13 ± .23) with no significant difference on the third day of treatment (p>0.05). In separate serial studies, microfocal X-ray CT of ex vivo brain specimens (N = 9) and immunohistochemistry for endothelial cell marker anti-CD31 (N = 8) were performed. Vascular morphology of ex vivo rat brains from micro-CT analysis showed hypervascular characteristics in tumors, and both vessel density (41.32 ± 2.34 branches/mm(3), p<0.001) and vessel tortuosity (p<0.05) were significantly reduced in tumors of rats treated with dexamethasone compared to saline (74.29 ± 3.51 branches/mm(3)). The vascular architecture of rat brain tissue was examined with anti-CD31 antibody, and dexamethasone treated tumor regions showed reduced vessel area (16.45 ± 1.36 µm(2)) as compared to saline treated tumor regions (30.83 ± 4.31 µm(2), p<0.001) and non-tumor regions (22.80 ± 1.11 µm(2), p<0.01).Increased vascular density and tortuosity are culprit to abnormal perfusion, which is transiently reduced during dexamethasone treatment
Multi-particle azimuthal correlations in p-Pb and Pb-Pb collisions at the CERN Large Hadron Collider
Measurements of multi-particle azimuthal correlations (cumulants) for charged
particles in p-Pb and Pb-Pb collisions are presented. They help address the
question of whether there is evidence for global, flow-like, azimuthal
correlations in the p-Pb system. Comparisons are made to measurements from the
larger Pb-Pb system, where such evidence is established. In particular, the
second harmonic two-particle cumulants are found to decrease with multiplicity,
characteristic of a dominance of few-particle correlations in p-Pb collisions.
However, when a gap is placed to suppress such correlations,
the two-particle cumulants begin to rise at high-multiplicity, indicating the
presence of global azimuthal correlations. The Pb-Pb values are higher than the
p-Pb values at similar multiplicities. In both systems, the second harmonic
four-particle cumulants exhibit a transition from positive to negative values
when the multiplicity increases. The negative values allow for a measurement of
to be made, which is found to be higher in Pb-Pb collisions at
similar multiplicities. The second harmonic six-particle cumulants are also
found to be higher in Pb-Pb collisions. In Pb-Pb collisions, we generally find
which is indicative of a Bessel-Gaussian
function for the distribution. For very high-multiplicity Pb-Pb
collisions, we observe that the four- and six-particle cumulants become
consistent with 0. Finally, third harmonic two-particle cumulants in p-Pb and
Pb-Pb are measured. These are found to be similar for overlapping
multiplicities, when a gap is placed.Comment: 25 pages, 11 captioned figures, 3 tables, authors from page 20,
published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/87
Multiplicity dependence of jet-like two-particle correlations in p-Pb collisions at = 5.02 TeV
Two-particle angular correlations between unidentified charged trigger and
associated particles are measured by the ALICE detector in p-Pb collisions at a
nucleon-nucleon centre-of-mass energy of 5.02 TeV. The transverse-momentum
range 0.7 5.0 GeV/ is examined,
to include correlations induced by jets originating from low
momen\-tum-transfer scatterings (minijets). The correlations expressed as
associated yield per trigger particle are obtained in the pseudorapidity range
. The near-side long-range pseudorapidity correlations observed in
high-multiplicity p-Pb collisions are subtracted from both near-side
short-range and away-side correlations in order to remove the non-jet-like
components. The yields in the jet-like peaks are found to be invariant with
event multiplicity with the exception of events with low multiplicity. This
invariance is consistent with the particles being produced via the incoherent
fragmentation of multiple parton--parton scatterings, while the yield related
to the previously observed ridge structures is not jet-related. The number of
uncorrelated sources of particle production is found to increase linearly with
multiplicity, suggesting no saturation of the number of multi-parton
interactions even in the highest multiplicity p-Pb collisions. Further, the
number scales in the intermediate multiplicity region with the number of binary
nucleon-nucleon collisions estimated with a Glauber Monte-Carlo simulation.Comment: 23 pages, 6 captioned figures, 1 table, authors from page 17,
published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/161
Anisotropic flow of charged hadrons, pions and (anti-)protons measured at high transverse momentum in Pb-Pb collisions at TeV
The elliptic, , triangular, , and quadrangular, , azimuthal
anisotropic flow coefficients are measured for unidentified charged particles,
pions and (anti-)protons in Pb-Pb collisions at TeV
with the ALICE detector at the Large Hadron Collider. Results obtained with the
event plane and four-particle cumulant methods are reported for the
pseudo-rapidity range at different collision centralities and as a
function of transverse momentum, , out to GeV/.
The observed non-zero elliptic and triangular flow depends only weakly on
transverse momentum for GeV/. The small dependence
of the difference between elliptic flow results obtained from the event plane
and four-particle cumulant methods suggests a common origin of flow
fluctuations up to GeV/. The magnitude of the (anti-)proton
elliptic and triangular flow is larger than that of pions out to at least
GeV/ indicating that the particle type dependence persists out
to high .Comment: 16 pages, 5 captioned figures, authors from page 11, published
version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/186
Centrality dependence of charged particle production at large transverse momentum in Pb-Pb collisions at TeV
The inclusive transverse momentum () distributions of primary
charged particles are measured in the pseudo-rapidity range as a
function of event centrality in Pb-Pb collisions at
TeV with ALICE at the LHC. The data are presented in the range
GeV/ for nine centrality intervals from 70-80% to 0-5%.
The Pb-Pb spectra are presented in terms of the nuclear modification factor
using a pp reference spectrum measured at the same collision
energy. We observe that the suppression of high- particles strongly
depends on event centrality. In central collisions (0-5%) the yield is most
suppressed with at -7 GeV/. Above
GeV/, there is a significant rise in the nuclear modification
factor, which reaches for GeV/. In
peripheral collisions (70-80%), the suppression is weaker with almost independently of . The measured nuclear
modification factors are compared to other measurements and model calculations.Comment: 17 pages, 4 captioned figures, 2 tables, authors from page 12,
published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/284
- …