1,293 research outputs found

    A case of an obstructive intramural haematoma during percutaneous coronary intervention successfully treated with intima microfenestrations utilising a cutting balloon inflation technique

    Get PDF
    During percutaneous coronary interventions (PCI), good lesion preparation with adequate balloon predilatation is a fundamental step before stent deployment in order to achieve optimal stent expansion and favourable long-term outcomes post PCI. During PCI, inadvertent vessel tearing can occur, resulting in coronary dissections and formation of intramural haematomas. The latter might be associated with compression of the vessel lumen and significant compromise of the coronary blood flow leading to myocardial ischaemia and infarction. Herein, we present a case of intramural haematoma that occurred after PCI of the left anterior descending artery resulting in occlusion of the vessel and the subsequent use of a cutting balloon inflation technique to resolve the haematoma and restore the normal coronary blood flow

    The role of intravascular imaging in chronic total occlusion percutaneous coronary intervention

    Get PDF
    Chronic total occlusions (CTOs) represent the most complex subset of coronary artery disease and therefore careful planning of CTO percutaneous coronary recanalization (PCI) strategy is of paramount importance aiming to achieve procedural success, and improve patient's safety and post CTO PCI outcomes. Intravascular imaging has an essential role in facilitating CTO PCΙ. First, intravascular ultrasound (IVUS), due to its higher penetration depth compared to optical coherence tomography (OCT), and the additional capacity of real-time imaging without need for contrast injection is considered the preferred imaging modality for CTO PCI. Secondly, IVUS can be used to resolve proximal cap ambiguity, facilitate wire re-entry when dissection and re-entry strategies are applied and most importantly to guide stent deployment and optimization post implantation. The role of OCT during CTO PCI is currently limited to stent sizing and optimization, however, due to its high spatial resolution, OCT is ideal for detecting stent edge dissections and strut malapposition. In this review, we describe the use of intravascular imaging for lesion crossing, plaque characterization and wire tracking, extra- or intra-plaque, and stent sizing and optimization during CTO PCI and summarize the findings of the major studies in this field

    Impact of intravascular ultrasound on chronic total occlusion percutaneous revascularization

    Get PDF
    Aim: We sought to investigate the impact of IVUS use on chronic total occlusion (CTO) PCI using data from a contemporary registry of consecutive patients and applying a propensity score matching analysis. Methods and results: We evaluated 514 successful CTO-PCIs, median age: 67 years (IQR: 58–73), 83.5% males. IVUS-guided PCI was performed in 184 (35.8%) of cases. After using 1:1 propensity matching score analysis, two groups of 182 patients each (IVUS-guided vs. angiography-guided CTO-PCI group) were produced to form the study population. In the IVUS-guided group the median maximum stent diameter was larger and the median total stented segment was longer compared to the angiography-guided group [(3.5 mm, IQR: 3.0–4.0 vs. 3.2 mm, IQR: 3.0–3.5, p < 0.001) and (60.0 mm, IQR: 38.0–91.3 vs. 38.0 mm, IQR: 32.0–70.5, p < 0.001), respectively]. In the IVUS-guided group, retrograde recanalization was more frequently encountered compared to the angiography-guided PCI group (30.2% vs. 20.9%, p = 0.04). Procedural time was significantly longer in the IVUS-guided group, without any difference in fluoroscopy time, radiation dose and contrast volume. Multivariate linear regression analysis showed that IVUS use was the strongest independent factor associated with larger maximum diameter stents (p < 0.001) and a strong independent predictor for total stented segment length during CTO-PCI (p < 0.001). Up to 8 years follow-up, there was no difference in the incidence of the composite endpoint of all-cause death, cardiac death, myocardial infarction and target vessel revascularization between the IVUS-guided PCI and the angiography-guided PCI groups (hazard ratio: 13.7% vs. 15.9%, respectively, log-rank: p = 0.67, median follow-up time: 49.0 months, IQR: 33.0–67.0). Conclusions: Use of IVUS in CTO-PCI was associated with larger stent diameter and longer stented segments. Despite more frequent use of IVUS in retrograde CTO-PCI, there was no difference in long-term adverse events between IVUS and angiography CTO-PCI groups; nevertheless, the study was not powered to assess clinical outcomes

    Eosinophilic pneumonia associated with daptomycin: a case report and a review of the literature

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Although several studies did not demonstrate that daptomycin may cause significantly higher rates of pulmonary adverse effects when compared with vancomycin or penicillinase-resistant penicillins, there have been a few case reports of severe pulmonary complications associated with daptomycin administration.</p> <p>Case presentation</p> <p>A rare case of eosinophilic pneumonia occurring 10 days after daptomycin administration in a 78-year-old Caucasian man with possible infectious endocarditis is described. He developed new onset fever, up to 38.5°C, with bilateral pulmonary crackles on physical examination and with no signs of severe respiratory failure. A chest computed tomography-scan showed bilateral nodular consolidations with air bronchograms and pleural effusions. Immediate discontinuation of daptomycin was followed by vigorous improvement of clinical signs and symptoms with progressive resolution of pulmonary consolidations a month later.</p> <p>Conclusion</p> <p>Physicians should be aware of this rare but serious complication during daptomycin treatment, and prompt discontinuation of the offending agent, with or without additional supportive treatment, must occur immediately.</p

    Search for supersymmetry in events with b-quark jets and missing transverse energy in pp collisions at 7 TeV

    Get PDF
    Results are presented from a search for physics beyond the standard model based on events with large missing transverse energy, at least three jets, and at least one, two, or three b-quark jets. The study is performed using a sample of proton-proton collision data collected at sqrt(s) = 7 TeV with the CMS detector at the LHC in 2011. The integrated luminosity of the sample is 4.98 inverse femtobarns. The observed number of events is found to be consistent with the standard model expectation, which is evaluated using control samples in the data. The results are used to constrain cross sections for the production of supersymmetric particles decaying to b-quark-enriched final states in the context of simplified model spectra.Comment: Submitted to Physical Review

    Discovery of Genetic Variation on Chromosome 5q22 Associated with Mortality in Heart Failure

    Get PDF
    Failure of the human heart to maintain sufficient output of blood for the demands of the body, heart failure, is a common condition with high mortality even with modern therapeutic alternatives. To identify molecular determinant

    Measurement of the prompt J/psi and psi(2S) polarizations in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    The polarizations of prompt J/psi and psi(2S) mesons are measured in proton-proton collisions at sqrt(s) = 7 TeV, using a dimuon data sample collected by the CMS experiment at the LHC, corresponding to an integrated luminosity of 4.9 inverse femtobarns. The prompt J/psi and psi(2S) polarization parameters lambda[theta], lambda[phi], and lambda[theta, phi], as well as the frame-invariant quantity lambda(tilde), are measured from the dimuon decay angular distributions in three different polarization frames. The J/psi results are obtained in the transverse momentum range 14 &lt; pt &lt; 70 GeV, in the rapidity intervals abs(y) &lt; 0.6 and 0.6 &lt; abs(y) &lt; 1.2. The corresponding psi(2S) results cover 14 &lt; pt &lt; 50 GeV and include a third rapidity bin, 1.2 &lt; abs(y) &lt; 1.5. No evidence of large transverse or longitudinal polarizations is seen in these kinematic regions, which extend much beyond those previously explored

    Measurement of the underlying event activity in pp collisions at √s = 0.9 and 7 TeV with the novel jet-area/median approach

    Get PDF
    Open Access: This article is distributed under the terms of the Creative Commons Attribution License.-- Chatrchyan, S. et al.The first measurement of the charged component of the underlying event using the novel >jet-area/median> approach is presented for proton-proton collisions at centre-of-mass energies of 0.9 and 7 TeV. The data were recorded in 2010 with the CMS experiment at the LHC. A new observable, sensitive to soft particle production, is introduced and investigated inclusively and as a function of the event scale defined by the transverse momentum of the leading jet. Various phenomenological models are compared to data, with and without corrections for detector effects. None of the examined models describe the data satisfactorily. © 2012 SISSA.Acknowledge support from BMWF and FWF (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); MoER, SF0690030s09 and ERDF (Estonia); Academy of Finland, MEC, and HIP (Finland); CEA and CNRS/IN2P3 (France);BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF and WCU (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); MSI (New Zealand); PAEC (Pakistan); MSHE and NSC (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MON, RosAtom, RAS and RFBR (Russia); MSTD (Serbia); SEIDI and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); ThEP, IPST and NECTEC (Thailand); TUBITAK and TAEK (Turkey); NASU (Ukraine); STFC (United Kingdom); DOE and NSF (USA). Individuals have received support from the Marie-Curie program and the European Research Council (European Union); the Leventis Foundation; the A. P. Sloan Foundation; the Alexander von Humboldt Foundation; the Austrian Science Fund (FWF); the Belgian Federal Science Policy Office; the Fonds pour la Formation à la Recherche dans l’Industrie et dans l’Agriculture (FRIA-Belgium); the Agentschap voor Innovatie door Wetenschap en Technologie (IWTBelgium); the Ministry of Education, Youth and Sports (MEYS) of Czech Republic; the Council of Science and Industrial Research, India; the Compagnia di San Paolo (Torino); and the HOMING PLUS program of Foundation for Polish Science, cofinanced from European Union, Regional Development Fund.Peer Reviewe
    • …
    corecore