21 research outputs found
Correlations between emotional and behavioral factors and the EDI-3 by sex
The Eating Disorder Inventory 3 (EDI-3) is one of the most commonly used measures for assessing symptoms associated with eating disorders. Several studies have examined differences in scores on the EDI-3 constructs based on sex, however; few have examined potential behavioral and/or emotional factors that may be related to scores on the EDI-3. The purpose of this study was to consider how the domains of the Behavioral Assessment System for Children, Second Edition Self Report of Personality College Form (BASC-2 SRP COL) correlated to the constructs of the EDI-3 by sex in a population of college students. The results revealed significant Pearsonâs Product-Moment Correlation coefficients in all five of the EDI-3 constructs evaluated and at least one BASC-2 SRP COL scale in females. In addition, significant correlations were observed between four of the five EDI-3 composites considered and at least one BASC-2 SRP COL scales in males. Implications for future research will be discussed within the text
Optimal Configuration of Proton-Therapy Accelerators for Relative-Stopping-Power Resolution in Proton Computed Tomography
Magnetic-field measurement and analysis for the Muon g â 2 Experiment at Fermilab
The Fermi National Accelerator Laboratory (FNAL) Muon g - 2 Experiment has measured the anomalous precession frequency a_{ÎŒ}(g_{ÎŒ} - 2)/2 of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7C. The measured field is weighted by the muon distribution resulting in \tilde{Ï}'_{p}, the denominator in the ratio \tilde{Ï}_{a}/\tilde{Ï}'_{p} that together with known fundamental constants yields aÎŒ. The reported uncertainty on \tilde{Ï}'_{p} for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 dataset of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency Ïam are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary, because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to Ï_{a}^{m} is 0.50±0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of Ï_{a}^{m}
Outcomes from elective colorectal cancer surgery during the SARS-CoV-2 pandemic
This study aimed to describe the change in surgical practice and the impact of SARS-CoV-2 on mortality after surgical resection of colorectal cancer during the initial phases of the SARS-CoV-2 pandemic
Pooled analysis of WHO Surgical Safety Checklist use and mortality after emergency laparotomy
Background The World Health Organization (WHO) Surgical Safety Checklist has fostered safe practice for 10 years, yet its place in emergency surgery has not been assessed on a global scale. The aim of this study was to evaluate reported checklist use in emergency settings and examine the relationship with perioperative mortality in patients who had emergency laparotomy. Methods In two multinational cohort studies, adults undergoing emergency laparotomy were compared with those having elective gastrointestinal surgery. Relationships between reported checklist use and mortality were determined using multivariable logistic regression and bootstrapped simulation. Results Of 12 296 patients included from 76 countries, 4843 underwent emergency laparotomy. After adjusting for patient and disease factors, checklist use before emergency laparotomy was more common in countries with a high Human Development Index (HDI) (2455 of 2741, 89.6 per cent) compared with that in countries with a middle (753 of 1242, 60.6 per cent; odds ratio (OR) 0.17, 95 per cent c.i. 0.14 to 0.21, P <0001) or low (363 of 860, 422 per cent; OR 008, 007 to 010, P <0.001) HDI. Checklist use was less common in elective surgery than for emergency laparotomy in high-HDI countries (risk difference -94 (95 per cent c.i. -11.9 to -6.9) per cent; P <0001), but the relationship was reversed in low-HDI countries (+121 (+7.0 to +173) per cent; P <0001). In multivariable models, checklist use was associated with a lower 30-day perioperative mortality (OR 0.60, 0.50 to 073; P <0.001). The greatest absolute benefit was seen for emergency surgery in low- and middle-HDI countries. Conclusion Checklist use in emergency laparotomy was associated with a significantly lower perioperative mortality rate. Checklist use in low-HDI countries was half that in high-HDI countries.Peer reviewe
Measurement of the anomalous precession frequency of the muon in the Fermilab Muon g-2 Experiment
The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has
measured the muon anomalous precession frequency to an uncertainty
of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data
collected in four storage ring configurations during its first physics run in
2018. When combined with a precision measurement of the magnetic field of the
experiment's muon storage ring, the precession frequency measurement determines
a muon magnetic anomaly of (0.46 ppm). This article describes the multiple techniques employed
in the reconstruction, analysis and fitting of the data to measure the
precession frequency. It also presents the averaging of the results from the
eleven separate determinations of \omega_a, and the systematic uncertainties on
the result.Comment: 29 pages, 19 figures. Published in Physical Review
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to is 0.50 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of
Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7C. The measured field is weighted by the muon distribution resulting in , the denominator in the ratio / that together with known fundamental constants yields . The reported uncertainty on for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to is 0.50 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of