43 research outputs found

    Protocol for a multicentre, parallelgroup, open-label randomised controlled trial comparing ferric carboxymaltose with the standard of care in anaemic Malawian pregnant women: the REVAMP trial

    Get PDF
    Introduction Anaemia in pregnancy remains a critical global health problem, affecting 46% of pregnant women in Africa and 49% in Asia. Oral iron therapy requires extended adherence to achieve correction of anaemia and replenishment of iron stores. Ferric carboxymaltose (FCM) is a recently established intravenous iron formulation associated with substantial advantages in safety, speed of delivery and total dose deliverable in a single infusion. We aim to determine whether FCM given once during the second trimester of pregnancy compared with standard oral iron distributed through routine antenatal services is effective and safe for treatment of moderate to severe maternal anaemia in sub-Saharan Africa. Methods and analysis The randomized controlled trial of the effect of intravenous iron on anaemia in Malawian pregnant women (REVAMP) is a two-arm confirmatory individually randomised trial set in Blantyre and Zomba districts in Malawi. The trial will randomise 862 women in the second trimester of pregnancy with a capillary haemoglobin concentration below 100.0 g/L. The study comprises two arms: (a) intravenous FCM (20 mg/kg up to 1000 mg) given once at randomisation, and (b) standard of care oral iron (65 mg elemental iron two times per day) for 90 days (or the duration of pregnancy, whichever is shorter) provided according to local healthcare practices. Both arms receive sulfadoxine-pyrimethamine as intermittent preventive treatment in pregnancy. The primary outcome is the prevalence of anaemia (Hb <110.0 g/L) at 36 weeks’ gestation. Secondary outcomes include birth weight, gestation duration and safety outcomes, including clinical malaria, serious perinatal events and postpartum haematologic and health-related outcomes in the mother and child. Ethics and dissemination Ethical approval was granted by the Research Ethics Committee (COMREC P.02/18/2357) in Malawi and the Human Research Ethics Committee (WEHI: 18/02), Melbourne, Australia. The protocol is registered with the Australian and New Zealand Clinical Trials Registry. The results will be shared with the local community that enabled the research, and also to the international fora.publishedVersio

    A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies

    A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies

    Finishing the euchromatic sequence of the human genome

    Get PDF
    The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead

    Tropical Data: Approach and Methodology as Applied to Trachoma Prevalence Surveys

    Get PDF
    PURPOSE: Population-based prevalence surveys are essential for decision-making on interventions to achieve trachoma elimination as a public health problem. This paper outlines the methodologies of Tropical Data, which supports work to undertake those surveys. METHODS: Tropical Data is a consortium of partners that supports health ministries worldwide to conduct globally standardised prevalence surveys that conform to World Health Organization recommendations. Founding principles are health ministry ownership, partnership and collaboration, and quality assurance and quality control at every step of the survey process. Support covers survey planning, survey design, training, electronic data collection and fieldwork, and data management, analysis and dissemination. Methods are adapted to meet local context and needs. Customisations, operational research and integration of other diseases into routine trachoma surveys have also been supported. RESULTS: Between 29th February 2016 and 24th April 2023, 3373 trachoma surveys across 50 countries have been supported, resulting in 10,818,502 people being examined for trachoma. CONCLUSION: This health ministry-led, standardised approach, with support from the start to the end of the survey process, has helped all trachoma elimination stakeholders to know where interventions are needed, where interventions can be stopped, and when elimination as a public health problem has been achieved. Flexibility to meet specific country contexts, adaptation to changes in global guidance and adjustments in response to user feedback have facilitated innovation in evidence-based methodologies, and supported health ministries to strive for global disease control targets

    The evolving SARS-CoV-2 epidemic in Africa: Insights from rapidly expanding genomic surveillance

    Get PDF
    INTRODUCTION Investment in Africa over the past year with regard to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) sequencing has led to a massive increase in the number of sequences, which, to date, exceeds 100,000 sequences generated to track the pandemic on the continent. These sequences have profoundly affected how public health officials in Africa have navigated the COVID-19 pandemic. RATIONALE We demonstrate how the first 100,000 SARS-CoV-2 sequences from Africa have helped monitor the epidemic on the continent, how genomic surveillance expanded over the course of the pandemic, and how we adapted our sequencing methods to deal with an evolving virus. Finally, we also examine how viral lineages have spread across the continent in a phylogeographic framework to gain insights into the underlying temporal and spatial transmission dynamics for several variants of concern (VOCs). RESULTS Our results indicate that the number of countries in Africa that can sequence the virus within their own borders is growing and that this is coupled with a shorter turnaround time from the time of sampling to sequence submission. Ongoing evolution necessitated the continual updating of primer sets, and, as a result, eight primer sets were designed in tandem with viral evolution and used to ensure effective sequencing of the virus. The pandemic unfolded through multiple waves of infection that were each driven by distinct genetic lineages, with B.1-like ancestral strains associated with the first pandemic wave of infections in 2020. Successive waves on the continent were fueled by different VOCs, with Alpha and Beta cocirculating in distinct spatial patterns during the second wave and Delta and Omicron affecting the whole continent during the third and fourth waves, respectively. Phylogeographic reconstruction points toward distinct differences in viral importation and exportation patterns associated with the Alpha, Beta, Delta, and Omicron variants and subvariants, when considering both Africa versus the rest of the world and viral dissemination within the continent. Our epidemiological and phylogenetic inferences therefore underscore the heterogeneous nature of the pandemic on the continent and highlight key insights and challenges, for instance, recognizing the limitations of low testing proportions. We also highlight the early warning capacity that genomic surveillance in Africa has had for the rest of the world with the detection of new lineages and variants, the most recent being the characterization of various Omicron subvariants. CONCLUSION Sustained investment for diagnostics and genomic surveillance in Africa is needed as the virus continues to evolve. This is important not only to help combat SARS-CoV-2 on the continent but also because it can be used as a platform to help address the many emerging and reemerging infectious disease threats in Africa. In particular, capacity building for local sequencing within countries or within the continent should be prioritized because this is generally associated with shorter turnaround times, providing the most benefit to local public health authorities tasked with pandemic response and mitigation and allowing for the fastest reaction to localized outbreaks. These investments are crucial for pandemic preparedness and response and will serve the health of the continent well into the 21st century

    The Svedberg Lecture 2017. From nano to micro: the huge dynamic range of the analytical ultracentrifuge for characterising the sizes, shapes and interactions of molecules and assemblies in Biochemistry and Polymer Science

    No full text
    The analytical ultracentrifuge (AUC) invented by T. Svedberg has now become an extremely versatile and diverse tool in Biochemistry and Polymer Science for the characterisation of the sizes, shapes and interactions of particles ranging in size from a few nanometres to tens of microns, or in molecular weight, M (molar mass) terms from a few hundred daltons to hundreds of megadaltons. We illustrate this diversity by reviewing recent work on (1) small lignin-like isoeugenols of M ~ 0.4–0.9 kDa for archaeological wood conservation, (2) protein-like association of a functional amino-cellulose M = 3.25 kDa, (3) a small glycopeptide antibiotic (M ~ 1.5 kDa) and its association with a protein involved in antibiotic resistance (M ~ 47 kDa), (4) tetanus toxoid protein TTP (M ~ 150 kDa) and (5) the incorporation of TTP into two huge glycoconjugates considered in glycovaccine development with molecular weight species in a broad distribution appearing to reach 100 MDa. In illustrating the diversity, we will highlight developments in hydrodynamic analysis which have made the AUC such an exciting and important instrument, and point to a potential future development for extending its capability to highly concentrated systems

    Modelling biological macromolecules in solution: the general tri-axial ellipsoid

    Full text link
    Hydrodynamic shape functions for modelling biological macromolecules in solution in terms of an ellipsoid of revolution model are reviewed. Several new, hitherto unpublished shape functions whose experimental determination does not require knowledge of the swollen molecular volume in solution, are given. The limitations and inadequacies of this model are explained. The viscosity increment v for a dilute dispersion of tri-axial ellipsoids of semi-axes a> b> c, under dominant Brownian motion is derived and an explicit expression in terms of a, b and c is given. Knowledge of the viscosity increment alone is not sufficient to uniquely determine the axial ratios (a/b, b/c) because (i) in order to determine v, knowledge of the swollen volume in solution is required and (ii) a particular value for v has a line solution of possible values for (a/b, b/c). (i) is dealt with by combining v with the tri-axial frictional ratio function P to give the tri-axial R function and (ii) by combining graphically the R line solution with δ+ and δ- swelling independent line solutions. The experimental determination of δ+ and δ- requires the resolution of a 2-term electric birefringence decay into its component relaxation times; current data analysis techniques are however not satisfactory for resolving close relaxation times (as for globular proteins) with the current experimental precision. It is however shown by exhaustive computer simulation that using a new R-constrained nonlinear least squares iterative analysis this is now possible. It is thus concluded that the general tri-axial ellipsoid as a model for the gross conformation of biological macromolecules in solution can now be employed

    Characterisation of high molecular weight hop proanthocyanidins using Analytical Ultracentrifugation

    Get PDF
    We report the novel application of Analytical Ultracentrifugation (AUCF) to characterise the polymeric proanthocyanidin fraction of hops. Extraction of hop samples with 70% acetone (aq) followed by a C-18 Solid Phase Extraction yielded polyphenolic fractions for AUCF analysis. Sedimentation velocity experiments demonstrated the presence of discrete molecular weight bands of proanthocyanidins, as opposed to a continuous distribution of molecular weights. There were 4 such bands for Saaz hop (0.15, 1.1, 2.7 and 4.4S) and 3 bands for Magnum (0.15, 1.6 and 3.0S). The method resulted in a reproducible size (sedimentation coefficient) distribution for replicate runs of the same extract and for extracts prepared from different samples of the same hop variety. Sedimentation equilibrium experiments were then used to fit molecular weight distributions using the new SEDFIT-MSTAR method for the same samples. Thus we report for the first time polymeric proanthocyanidins in hops with molecular weights of up to 100 kDa in Saaz hop (or up to 56 kDa in Magnum). This represents the first application of AUCF to characterise complex fractions of polyphenolics extracted from botanical sources and the methodology developed should find wider application in the study of this diverse and bioactive class of compounds

    A simple cell-alignment protocol for sedimentation velocity analytical ultracentrifugation to complement mechanical and optical alignment procedures

    No full text
    In establishing the sources of data variability within sedimentation velocity analysis in the analytical ultracentrifuge and their relative importance, recent studies have demonstrated that alignment of the sample cells to the centre of rotation is the most significant contributing factor to overall variability, particularly for the characterisation of low levels of protein aggregation. Accurate mechanical and optical alignment tools have been recently designed. In this study, we (1) confirm the effect of misalignment observed by others on the estimated amounts of bovine serum albumin (BSA) monomer and dimer, and the sedimentation coefficient value for the BSA dimer; and (2) demonstrate the high performance of a mechanical alignment tool and the usefulness of a simple and complementary enhanced manual alignment protocol which should be useful for situations where these tools are not available
    corecore