97 research outputs found

    Instability and `Sausage-String' Appearance in Blood Vessels during High Blood Pressure

    Get PDF
    A new Rayleigh-type instability is proposed to explain the `sausage-string' pattern of alternating constrictions and dilatations formed in blood vessels under influence of a vasoconstricting agent. Our theory involves the nonlinear elasticity characteristics of the vessel wall, and provides predictions for the conditions under which the cylindrical form of a blood vessel becomes unstable.Comment: 4 pages, 4 figures submitted to Physical Review Letter

    Repetitive levosimendan infusions for patients with advanced chronic heart failure in the vulnerable post-discharge period

    Get PDF
    Hospitalization for acute heart failure (HF) is associated with a substantial morbidity burden and with associated healthcare costs and an increased mortality risk. However, few if any major medical innovations have been witnessed in this area in recent times. Levosimendan is a first-in-class calcium sensitizer and potassium channel opener indicated for the management of acute HF. Experience in several clinical studies has indicated that administration of intravenous levosimendan in intermittent cycles may reduce hospitalization and mortality rates in patients with advanced HF; however, none of those trials were designed or powered to give conclusive insights into that possibility. This paper describes the rationale and protocol of LeoDOR (levosimendan infusions for patients with advanced chronic heart failure), a randomized, double-blind, placebo-controlled, international, multicentre trial that will explore the efficacy and safety of intermittent levosimendan therapy, in addition to optimized standard therapy, in patients following hospitalization for acute HF. Salient features of LeoDOR include the use of two treatment regimens, in order to evaluate the effects of different schedules and doses of levosimendan during a 12 week treatment phase, and the use of a global rank primary endpoint, in which all patients are ranked across three hierarchical groups ranging from time to death or urgent heart transplantation or implantation of a ventricular assist device to time to rehospitalization and, lastly, time-averaged proportional change in N-terminal pro-brain natriuretic peptide. Secondary endpoints include changes in HF symptoms and functional status at 14 weeks

    The G0 Experiment: Apparatus for Parity-Violating Electron Scattering Measurements at Forward and Backward Angles

    Full text link
    In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized beam-monitoring and control systems, a cryogenic hydrogen (or deuterium) target, and a superconducting, toroidal magnetic spectrometer equipped with plastic scintillation and aerogel Cerenkov detectors, as well as fast readout electronics for the measurement of individual events. The overall design and performance of this experimental system is discussed.Comment: Submitted to Nuclear Instruments and Method

    2019 EACTS Expert Consensus on long-term mechanical circulatory support

    Get PDF
    Long-term mechanical circulatory support (LT-MCS) is an important treatment modality for patients with severe heart failure. Different devices are available, and many-sometimes contradictory-observations regarding patient selection, surgical techniques, perioperative management and follow-up have been published. With the growing expertise in this field, the European Association for Cardio-Thoracic Surgery (EACTS) recognized a need for a structured multidisciplinary consensus about the approach to patients with LT-MCS. However, the evidence published so far is insufficient to allow for generation of meaningful guidelines complying with EACTS requirements. Instead, the EACTS presents an expert opinion in the LT-MCS field. This expert opinion addresses patient evaluation and preoperative optimization as well as management of cardiac and non-cardiac comorbidities. Further, extensive operative implantation techniques are summarized and evaluated by leading experts, depending on both patient characteristics and device selection. The faculty recognized that postoperative management is multidisciplinary and includes aspects of intensive care unit stay, rehabilitation, ambulatory care, myocardial recovery and end-of-life care and mirrored this fact in this paper. Additionally, the opinions of experts on diagnosis and management of adverse events including bleeding, cerebrovascular accidents and device malfunction are presented. In this expert consensus, the evidence for the complete management from patient selection to end-of-life care is carefully reviewed with the aim of guiding clinicians in optimizing management of patients considered for or supported by an LT-MCS device

    Separation of the Longitudinal and Transverse Cross Sections in the p(ee'K)Lambda and p(ee'K)Sigma Reactions

    Full text link
    We report measurements of cross sections for the reaction p(e,e'K)Y, for both the Lambda and Sigma_0 hyperon states, at an invariant mass of W=1.84 GeV and four-momentum transfers 0.5<Q2<2 (GeV/c)2. Data were taken for three values of virtual photon polarization, allowing the decomposition of the cross sections into longitudinal and transverse components. The Lambda data is a revised analysis of prior work, whereas the Sigma_0 results have not been previously reported.Comment: 17 pages, 18 figures, REVTEX 4, submitted to Physical Review

    Child Studies Multiple - Collaborative play for thinking through theories and methods

    Get PDF
    This is the final version. Available on open access from Linköpings University Electronic Press via the DOI in this recordThis text is an exploration of collaborative thinking and writing through theories, methods, and experiences on the topic of the child, children, and childhood. It is a collaborative written text (with 32 authors) that sprang out of the experimental workshop Child Studies Multiple. The workshop and this text are about daring to stay with mess, “un-closure” , and uncertainty in order to investigate the (e)motions and complexities of being either a child or a researcher. The theoretical and methodological processes presented here offer an opportunity to shake the ground on which individual researchers stand by raising questions about scientific inspiration, theoretical and methodological productivity, and thinking through focusing on process, play, and collaboration. The effect of this is a questioning of the singular academic ‘I’ by exploring and showing what a plural ‘I’ can look like. It is about what the multiplicity of voice can offer research in a highly individualistic time. The article allows the reader to follow and watch the unconventional trial-and-error path of the ongoing-ness of exploring theories and methods together as a research community via methods of drama, palimpsest, and fictionary

    A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies

    A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies
    corecore