2,104 research outputs found
Tangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures
Background: Volar locking plate fixation has become the gold standard in the treatment of unstable distal radius fractures. Juxta-articular screws should be placed as close as possible to the subchondral zone, in an optimized length to buttress the articular surface and address the contralateral cortical bone. On the other hand, intra-articular screw misplacements will promote osteoarthritis, while the penetration of the contralateral bone surface may result in tendon irritations and ruptures. The intraoperative control of fracture reduction and implant positioning is limited in the common postero-anterior and true lateral two-dimensional (2D)-fluoroscopic views. Therefore, additional 2D-fluoroscopic views in different projections and intraoperative three-dimensional (3D) fluoroscopy were recently reported. Nevertheless, their utility has issued controversies.
Objectives: The following questions should be answered in this study; 1) Are the additional tangential view and the intraoperative 3D fluoroscopy useful in the clinical routine to detect persistent fracture dislocations and screw misplacements, to prevent revision surgery? 2) Which is the most dangerous plate hole for screw misplacement?
Patients and Methods: A total of 48 patients (36 females and 13 males) with 49 unstable distal radius fractures (22 x 23 A; 2 x 23 B, and 25 x 23 C) were treated with a 2.4 mm variable angle LCP Two-Column volar distal radius plate (Synthes GmbH, Oberdorf, Switzerland) during a 10-month period. After final fixation, according to the manufactures' technique guide and control of implant placement in the two common perpendicular 2D-fluoroscopic images (postero-anterior and true lateral), an additional tangential view and intraoperative 3D fluoroscopic scan were performed to control the anatomic fracture reduction and screw placements. Intraoperative revision rates due to screw misplacements (intra-articular or overlength) were evaluated. Additionally, the number of surgeons, time and radiation-exposure, for each step of the operating procedure, were recorded.
Results: In the standard 2D-fluoroscopic views (postero-anterior and true lateral projection), 22 screw misplacements of 232 inserted screws were not detected. Based on the additional tangential view, 12 screws were exchanged, followed by further 10 screws after performing the 3D fluoroscopic scan. The most lateral screw position had the highest risk for screw misplacement (accounting for 45.5% of all exchanged screws). The mean number of images for the tangential view was 3 ± 2.5 images. The mean surgical time was extended by 10.02 ± 3.82 minutes for the 3D fluoroscopic scan. An additional radiation exposure of 4.4 ± 4.5seconds, with a dose area product of 39.2 ± 14.5 cGy/cm2 were necessary for the tangential view and 54.4 ± 20.9 seconds with a dose area product of 2.1 ± 2.2 cGy/cm2, for the 3D fluoroscopic scan.
Conclusions: We recommend the additional 2D-fluoroscopic tangential view for detection of screw misplacements caused by overlength, with penetration on the dorsal cortical surface of the distal radius, predominantly observed for the most lateral screw position. The use of intraoperative 3D fluoroscopy did not become accepted in our clinical routine, due to the technical demanding and time consuming procedure, with a limited image quality so far
Stock Identification Methods Working Group (SIMWG)
The Stock Identification Methods Working Group (SIMWG) reviews new methods for the defi-nition and investigation of stock structure and provides advice to other ICES expert groups on how to interpret patterns of population structure. The identification of the spatial boundaries of exploited stocks is a fundamental requirement before any stock assessment or modelling can be contemplated, and therefore lies at the heart of resource management. SIMWG continues to provide annual updates on recent applications of stock identification methods to species assessed by ICES and on advances in stock identification methods. Based on the wide expertise of SIMWG members, the group provides reviews of recent literature on genetics, growth marks in calcified structures, life history parameters, morphometrics/ me-ristics, tagging, otolith shape, otolith chemistry, parasites and interdisciplinary approaches. A key activity of SIMWG is to address requests by ICES working groups for technical advice on issues of stock identity. In 2020, the working group reviewed the outcome of the Workshop on Stock Identification of North Sea Cod (WKNSCodID). SIMWG contributes to the general understanding of the biological features of the north Atlantic ecosystem through its work to describe fish population structure. Additionally, SIMWG’s annual reviews on advances in stock identification methods keeps ICES members abreast of best prac-tices in this field of study. SIMWG expert reviews on questions of stock structure for particular ICES species are directly relevant to the appropriate definition of stock and contribute to the accuracy of stock assessment and effectiveness of management actions. We see an important role for SIMWG in the future as ICES copes with the shifting distributions of fishery resources and questions regarding the appropriate definition of fish stocks. Understanding stock structure is a fundamental requirement before any assessment or modelling on a stock can be contemplated and SIMWG will continue to work with ICES expert groups to address pressing stock identifica-tion issues
Stock Identification Methods Working Group (SIMWG). 2021
The Stock Identification Methods Working Group (SIMWG) reviews new methods for the definition and investigation of stock structure and provides recommendations to other ICES expert groups on how to interpret patterns of population structure. In 2021, SIMWG continued providing annual updates on recent applications of stock identification methods to species assessed by ICES and on advances in stock identification methods. Based on the wide expertise of SIMWG members, the group provides reviews of recent literature on genetics, growth marks in calcified structures, life history parameters, morphometrics/ meristics, tagging, otolith shape, otolith chemistry, parasites and interdisciplinary approaches. The key activity of SIMWG is to address requests by ICES working groups for technical advice on issues of stock identity. In 2021, SIMWG reviewed the report of a project on herring stock structure upon request by the ICES Herring Assessment Working Group (HAWG). SIMWG contributes to the general understanding of the biological features of the north Atlantic ecosystem through its work to describe fish population structure. Additionally, SIMWG annual reviews on advances in stock identification methods keep ICES members abreast of best practices in this field of study. SIMWG expert reviews on questions of stock structure for particular ICES species are directly relevant to the appropriate definition of stock and contribute to the accuracy of stock assessment and effectiveness of management actions. We see an important role for SIMWG in the future as ICES is coping with the shifting distributions of fishery resources and questions regarding the appropriate definition of fish stocks. Understanding stock structure is a fundamental requirement before any assessment or modelling on a stock can be contemplated and SIMWG will continue to work with ICES expert groups to address pressing stock identification issues
Reversed T cell receptor docking on a major histocompatibility class I complex limits involvement in the immune response
The anti-viral T cell response is drawn from the naive T cell repertoire. During influenza infection, the CD8+ T cell response to an H-2Db-restricted nucleoprotein epitope (NP366) is characterized by preferential expansion of T cells bearing TRBV13+ T cell receptors (TCRs) and avoidance of TRBV17+ T cells, despite the latter dominating the naive precursor repertoire. We found two TRBV17+ TCRs that bound H-2Db-NP366 with a 180° reversed polarity compared to the canonical TCR-pMHC-I docking. The TRBV17 β-chain dominated the interaction and, whereas the complementarity determining region-3 (CDR3) loops exclusively mediated contacts with the MHC-I, peptide specificity was attributable to germline-encoded recognition. Nevertheless, the TRBV17+ TCR exhibited moderate affinity toward H-2Db-NP366 and was capable of signal transduction. Thus, the naive CD8+ T cell pool can comprise TCRs adopting reversed pMHC-I docking modes that limit their involvement in the immune response
Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV
A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay
channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7
TeV is presented. The data were collected at the LHC, with the CMS detector,
and correspond to an integrated luminosity of 4.6 inverse femtobarns. No
significant excess is observed above the background expectation, and upper
limits are set on the Higgs boson production cross section. The presence of the
standard model Higgs boson with a mass in the 270-440 GeV range is excluded at
95% confidence level.Comment: Submitted to JHE
Search for the standard model Higgs boson decaying into two photons in pp collisions at sqrt(s)=7 TeV
A search for a Higgs boson decaying into two photons is described. The
analysis is performed using a dataset recorded by the CMS experiment at the LHC
from pp collisions at a centre-of-mass energy of 7 TeV, which corresponds to an
integrated luminosity of 4.8 inverse femtobarns. Limits are set on the cross
section of the standard model Higgs boson decaying to two photons. The expected
exclusion limit at 95% confidence level is between 1.4 and 2.4 times the
standard model cross section in the mass range between 110 and 150 GeV. The
analysis of the data excludes, at 95% confidence level, the standard model
Higgs boson decaying into two photons in the mass range 128 to 132 GeV. The
largest excess of events above the expected standard model background is
observed for a Higgs boson mass hypothesis of 124 GeV with a local significance
of 3.1 sigma. The global significance of observing an excess with a local
significance greater than 3.1 sigma anywhere in the search range 110-150 GeV is
estimated to be 1.8 sigma. More data are required to ascertain the origin of
this excess.Comment: Submitted to Physics Letters
Measurement of isolated photon production in pp and PbPb collisions at sqrt(sNN) = 2.76 TeV
Isolated photon production is measured in proton-proton and lead-lead
collisions at nucleon-nucleon centre-of-mass energies of 2.76 TeV in the
pseudorapidity range |eta|<1.44 and transverse energies ET between 20 and 80
GeV with the CMS detector at the LHC. The measured ET spectra are found to be
in good agreement with next-to-leading-order perturbative QCD predictions. The
ratio of PbPb to pp isolated photon ET-differential yields, scaled by the
number of incoherent nucleon-nucleon collisions, is consistent with unity for
all PbPb reaction centralities.Comment: Submitted to Physics Letters
Adjustment of traumatic femur shortening assisted by an intramedullar skeletal kinetic distractor: a case report
2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series
<p>Abstract</p> <p>Background</p> <p>Screw fixation of pelvic ring fractures is a common, but demanding procedure and navigation techniques were introduced to increase the precision of screw placement. The purpose of this case series was the evaluation of screw misplacement rate and functional outcome of percutaneous screw fixation of pelvic ring disruptions using a 2D navigation system.</p> <p>Methods</p> <p>Between August 2004 and December 2007, 44 of 442 patients with pelvic injuries were included for closed reduction and percutaneous screw fixation of disrupted pelvic ring lesions using an optoelectronic 2D-fluoroscopic based navigation system. Operating and fluoroscopy time were measured, as well as peri- and postoperative complications documented. Screw position was assessed by postoperative CT scans. Quality of live was evaluated by SF 36-questionnaire in 40 of 44 patients at mean follow up 15.5 ± 1.2 month.</p> <p>Results</p> <p>56 iliosacral- and 29 ramus pubic-screws were inserted (mean operation time per screw 62 ± 4 minutes, mean fluoroscopy time per screw 123 ± 12 seconds). In post-operative CT-scans the screw position was assessed and graded as follows: I. secure positioning, completely in the cancellous bone (80%); II. secure positioning, but contacting cortical bone structures (14%); III. malplaced positioning, penetrating the cortical bone (6%). The malplacements predominantly occurred in bilateral overlapping screw fixation. No wound infection or iatrogenic neurovascular damage were observed. Four re-operations were performed, two of them due to implant-misplacement and two of them due to implant-failure.</p> <p>Conclusion</p> <p>2D-fluoroscopic navigation is a safe tool providing high accuracy of percutaneous screw placement for pelvic ring fractures, but in cases of a bilateral iliosacral screw fixation an increased risk for screw misplacement was observed. If additional ramus pubic screw fixations are performed, the retrograde inserted screws have to pass the iliopubic eminence to prevent an axial screw loosening.</p
- …