51 research outputs found

    Age norms for grating acuity and contrast sensitivity in children using eye tracking technology

    Get PDF
    Key messages: Visual acuity is the most used method to assess visual function in children. Contrast sensitivity complements the information provided for visual acuity, but it is not commonly used in clinical practice. Digital devices are increasingly used as a method to evaluate visual function, due to multiple advantages. Testing with these devices can improve the evaluation of visual development in children from a few months of age. Visual acuity and contrast sensitivity tests, using eye tracking technology, are able to measure visual function in children across a wide range of ages, objectively, quickly and without need of an experienced examiner. Purpose: To report age-normative values for grating visual acuity and contrast sensitivity in healthy children using a digital device with eye tracking technology and to validate the grating acuity test. Methods: In the first project of the study, we examined healthy children aged between 6 months and 7 years with normal ophthalmological assessment. Grating visual acuity (VA) and contrast sensitivity (CS) were assessed using a preferential gaze paradigm with a DIVE (Device for an Integral Visual Examination) assisted with eye tracking technology to provide age norms. For the validation project, we compared LEA grating test (LGT) with DIVE VA in a group of children aged between 6 months and 4 years with normal and abnormal visual development. Results: Fifty-seven children (2.86 ± 1.55 years) were examined with DIVE VA test and 44 successfully completed DIVE CS test (3.06 ± 1.41 years). Both, VA and CS values increased with age, mainly along the first two years of life. Sixty-nine patients (1.34 ± 0.61 years) were included in the DIVE VA test validation. The mean difference between LGT and DIVE VA was − 1.05 ± 4.54 cpd with 95% limits of agreement (LoA) of − 9.95–7.84 cpd. Agreement between the two tests was higher in children younger than 1 year with a mean difference of − 0.19 ± 4.02 cpd. Conclusions: DIVE is an automatic, objective and reliable tool to assess several visual function parameters in children, and it has good agreement with classical VA tests, especially for the first stage of life

    An optoelectronic sensing device for CO detection in air based on a binuclear rhodium complex

    Full text link
    The design, fabrication and validation of an optoelectronic sensor implemented in an easy-to-use portable device for the selective and sensitive detection of CO in air is reported herein. The system is based on the colour changes observed in the binuclear rhodium complex of formula [Rh2[(C6H4)P(C6H5)2]2(O2CCF3)2](CF3CO2H)2(1) upon coordinating CO molecules in axial positions. Complex 1 is used supported on cellulose chromatography paper. In this support, colour changes to the naked eye are observed for CO concentrations above 50 ppm. The probe is also implemented in a simple portable optoelectronic device.The cellulose support containing probe 1 in this device is placed inside a small dark chamber, is illuminated with a tricolour LED emitting at 624, 525 and 470 nm, respectively corresponding to red (R), green (G) and blue (B) light, and reflected light is detected by a photodiode. With a transimpedance amplifier, the current generated by the photodiode is transformed into a voltage compatible with the 10-bit analogue-to-digital converter (ADC) port. Colour changes are measured as the distance d between the R, G and B data of the blank (probe without CO) and that for a certain CO concentration. Typical calibration curves are fitted using a bi-exponential equation. This system offers a typical response time of a few minutes (ca. 7 min) and a limit of detection of 11 ppm. The probe in the cellulose supports is also highly reversible.The optoelectronic device is portable (dimensions 14 × 8.5 × 3.5 cm; weighs approximately 270 g) and is powered by AA batteries. In addition, no variations in experimental parameter d upon exposure to CO2, N2, O2, Ar, water-saturated air and vapours of chloroform, hexane, ethanol, acetone, methane, toluene or formaldehyde are observed. Besides, colour changes are found for acetonitrile vapour, NO and NO2, but only at high concentrations. For validation purposes, the device was used to determine the CO present in the 4-shed accumulated smoke of two cigarette types after passing smokers lungs.We thank the Spanish Government (Project MAT2012-38429-C04-01), Generalitat Valenciana (Projects PROMETE02009/016 and ISIC/2012/005) and the UPV (Project INNOVA-04-10) for support. M.E.M thanks the Spanish Ministry of Education for a Doctoral FPU Fellowship.Moragues Pons, ME.; Montes Robles, R.; Ros-Lis, JV.; Alcañiz Fillol, M.; Ibáñez Civera, FJ.; Pardo Vicente, MT.; Martínez Mañez, R. (2014). An optoelectronic sensing device for CO detection in air based on a binuclear rhodium complex. Sensors and Actuators B: Chemical. 191:257-263. https://doi.org/10.1016/j.snb.2013.09.107S25726319

    Spontaneous Breathing in Early Acute Respiratory Distress Syndrome: Insights From the Large Observational Study to UNderstand the Global Impact of Severe Acute Respiratory FailurE Study

    Get PDF
    OBJECTIVES: To describe the characteristics and outcomes of patients with acute respiratory distress syndrome with or without spontaneous breathing and to investigate whether the effects of spontaneous breathing on outcome depend on acute respiratory distress syndrome severity. DESIGN: Planned secondary analysis of a prospective, observational, multicentre cohort study. SETTING: International sample of 459 ICUs from 50 countries. PATIENTS: Patients with acute respiratory distress syndrome and at least 2 days of invasive mechanical ventilation and available data for the mode of mechanical ventilation and respiratory rate for the 2 first days. INTERVENTIONS: Analysis of patients with and without spontaneous breathing, defined by the mode of mechanical ventilation and by actual respiratory rate compared with set respiratory rate during the first 48 hours of mechanical ventilation. MEASUREMENTS AND MAIN RESULTS: Spontaneous breathing was present in 67% of patients with mild acute respiratory distress syndrome, 58% of patients with moderate acute respiratory distress syndrome, and 46% of patients with severe acute respiratory distress syndrome. Patients with spontaneous breathing were older and had lower acute respiratory distress syndrome severity, Sequential Organ Failure Assessment scores, ICU and hospital mortality, and were less likely to be diagnosed with acute respiratory distress syndrome by clinicians. In adjusted analysis, spontaneous breathing during the first 2 days was not associated with an effect on ICU or hospital mortality (33% vs 37%; odds ratio, 1.18 [0.92-1.51]; p = 0.19 and 37% vs 41%; odds ratio, 1.18 [0.93-1.50]; p = 0.196, respectively ). Spontaneous breathing was associated with increased ventilator-free days (13 [0-22] vs 8 [0-20]; p = 0.014) and shorter duration of ICU stay (11 [6-20] vs 12 [7-22]; p = 0.04). CONCLUSIONS: Spontaneous breathing is common in patients with acute respiratory distress syndrome during the first 48 hours of mechanical ventilation. Spontaneous breathing is not associated with worse outcomes and may hasten liberation from the ventilator and from ICU. Although these results support the use of spontaneous breathing in patients with acute respiratory distress syndrome independent of acute respiratory distress syndrome severity, the use of controlled ventilation indicates a bias toward use in patients with higher disease severity. In addition, because the lack of reliable data on inspiratory effort in our study, prospective studies incorporating the magnitude of inspiratory effort and adjusting for all potential severity confounders are required

    Epidemiology and patterns of tracheostomy practice in patients with acute respiratory distress syndrome in ICUs across 50 countries

    Get PDF
    Background: To better understand the epidemiology and patterns of tracheostomy practice for patients with acute respiratory distress syndrome (ARDS), we investigated the current usage of tracheostomy in patients with ARDS recruited into the Large Observational Study to Understand the Global Impact of Severe Acute Respiratory Failure (LUNG-SAFE) study. Methods: This is a secondary analysis of LUNG-SAFE, an international, multicenter, prospective cohort study of patients receiving invasive or noninvasive ventilation in 50 countries spanning 5 continents. The study was carried out over 4 weeks consecutively in the winter of 2014, and 459 ICUs participated. We evaluated the clinical characteristics, management and outcomes of patients that received tracheostomy, in the cohort of patients that developed ARDS on day 1-2 of acute hypoxemic respiratory failure, and in a subsequent propensity-matched cohort. Results: Of the 2377 patients with ARDS that fulfilled the inclusion criteria, 309 (13.0%) underwent tracheostomy during their ICU stay. Patients from high-income European countries (n = 198/1263) more frequently underwent tracheostomy compared to patients from non-European high-income countries (n = 63/649) or patients from middle-income countries (n = 48/465). Only 86/309 (27.8%) underwent tracheostomy on or before day 7, while the median timing of tracheostomy was 14 (Q1-Q3, 7-21) days after onset of ARDS. In the subsample matched by propensity score, ICU and hospital stay were longer in patients with tracheostomy. While patients with tracheostomy had the highest survival probability, there was no difference in 60-day or 90-day mortality in either the patient subgroup that survived for at least 5 days in ICU, or in the propensity-matched subsample. Conclusions: Most patients that receive tracheostomy do so after the first week of critical illness. Tracheostomy may prolong patient survival but does not reduce 60-day or 90-day mortality. Trial registration: ClinicalTrials.gov, NCT02010073. Registered on 12 December 2013

    Hyperoxemia and excess oxygen use in early acute respiratory distress syndrome : Insights from the LUNG SAFE study

    Get PDF
    Publisher Copyright: © 2020 The Author(s). Copyright: Copyright 2020 Elsevier B.V., All rights reserved.Background: Concerns exist regarding the prevalence and impact of unnecessary oxygen use in patients with acute respiratory distress syndrome (ARDS). We examined this issue in patients with ARDS enrolled in the Large observational study to UNderstand the Global impact of Severe Acute respiratory FailurE (LUNG SAFE) study. Methods: In this secondary analysis of the LUNG SAFE study, we wished to determine the prevalence and the outcomes associated with hyperoxemia on day 1, sustained hyperoxemia, and excessive oxygen use in patients with early ARDS. Patients who fulfilled criteria of ARDS on day 1 and day 2 of acute hypoxemic respiratory failure were categorized based on the presence of hyperoxemia (PaO2 > 100 mmHg) on day 1, sustained (i.e., present on day 1 and day 2) hyperoxemia, or excessive oxygen use (FIO2 ≥ 0.60 during hyperoxemia). Results: Of 2005 patients that met the inclusion criteria, 131 (6.5%) were hypoxemic (PaO2 < 55 mmHg), 607 (30%) had hyperoxemia on day 1, and 250 (12%) had sustained hyperoxemia. Excess FIO2 use occurred in 400 (66%) out of 607 patients with hyperoxemia. Excess FIO2 use decreased from day 1 to day 2 of ARDS, with most hyperoxemic patients on day 2 receiving relatively low FIO2. Multivariate analyses found no independent relationship between day 1 hyperoxemia, sustained hyperoxemia, or excess FIO2 use and adverse clinical outcomes. Mortality was 42% in patients with excess FIO2 use, compared to 39% in a propensity-matched sample of normoxemic (PaO2 55-100 mmHg) patients (P = 0.47). Conclusions: Hyperoxemia and excess oxygen use are both prevalent in early ARDS but are most often non-sustained. No relationship was found between hyperoxemia or excessive oxygen use and patient outcome in this cohort. Trial registration: LUNG-SAFE is registered with ClinicalTrials.gov, NCT02010073publishersversionPeer reviewe

    Genetic tool development in marine protists: emerging model organisms for experimental cell biology

    Get PDF
    Abstract: Diverse microbial ecosystems underpin life in the sea. Among these microbes are many unicellular eukaryotes that span the diversity of the eukaryotic tree of life. However, genetic tractability has been limited to a few species, which do not represent eukaryotic diversity or environmentally relevant taxa. Here, we report on the development of genetic tools in a range of protists primarily from marine environments. We present evidence for foreign DNA delivery and expression in 13 species never before transformed and for advancement of tools for eight other species, as well as potential reasons for why transformation of yet another 17 species tested was not achieved. Our resource in genetic manipulation will provide insights into the ancestral eukaryotic lifeforms, general eukaryote cell biology, protein diversification and the evolution of cellular pathways
    corecore