31 research outputs found

    Measuring soot particles from automotive exhaust emissions

    Get PDF
    The European Metrology Research Programme participating countries and the European Union jointly fund a three year project to address the need of the automotive industry for a metrological sound base for exhaust measurements. The collaborative work on particle emissions involves five European National Metrology Institutes, the Tampere University of Technology, the Joint Research Centre for Energy and Transport and the Leibniz Institute for Tropospheric Research. On one hand, a particle number and size standard for soot particles is aimed for. Eventually this will allow the partners to provide accurate and comparable calibrations of measurement instruments for the type approval of Euro 5b and Euro 6 vehicles. Calibration aerosols of combustion particles, silver and graphite proof partially suitable. Yet, a consensus choice together with instrument manufactures is pending as the aerosol choice considerably affects the number concentration measurement. Furthermore, the consortium issued consistent requirements for novel measuring instruments foreseen to replace today’s opacimeters in regulatory periodic emission controls of soot and compared them with European legislative requirements. Four partners are conducting a metrological validation of prototype measurement instruments. The novel instruments base on light scattering, electrical, ionisation chamber and diffusion charging sensors and will be tested at low and high particle concentrations. Results shall allow manufacturers to further improve their instruments to comply with legal requirements

    Long-term persistence of HCV resistance-associated substitutions after DAA treatment failure

    Full text link
    BACKGROUND & AIMS: Data on the long-term persistence of HCV resistance-associated substitutions (RASs) after treatment with direct-acting antivirals (DAAs) are limited. This study evaluated the persistence of NS3, NS5A, and NS5B RASs for up to 5 years after the end of treatment (EOT). METHODS: We included samples from 678 individuals with an HCV genotype (GT) 1 or 3 infection and virologic DAA treatment failure collected in the European Resistance Database. NS3, NS5A, and NS5B were sequenced, and clinical parameters were evaluated. RESULTS: A total of 242 individuals with HCV GT1a (36%), 237 with GT1b (35%), and 199 (29%) with GT3 and a DAA failure were included. After protease inhibitor failure, the frequencies of NS3 RASs were 40-90% after the EOT. NS3 RASs disappeared rapidly in GT1b and GT3 after follow-up month 3 but were stable (≥60%) in GT1a owing to Q80K. The SOF-resistant NS5B RAS S282T was only found in individuals with GT3a. Non-nucleoside NS5B RASs were frequent in GT1 (56-80%) and decreased to 30% in GT1a but persisted in GT1b. NS5A RASs were very common in all GTs after NS5A inhibitor failure (88-95%), and even after follow-up month 24, their frequency was 65% and higher. However, RASs in GT1b had a stable course, whereas RASs in GT1a and GT3 declined slightly after follow-up month 24 (GT1a, 68%; GT1b, 95%; and GT3, 65%), mainly because of the slow decline of high-level resistant Y93H. CONCLUSIONS: We found that low-to medium-level RASs persisted, whereas high-level resistant RASs disappeared over time. Different patterns of RAS persistence according to HCV subtype could have implications for retreatment with first-generation DAAs and for global HCV elimination goals. IMPACT AND IMPLICATIONS: There are little data on the long-term persistence of HCV resistance-associated substitutions (RASs) after DAA treatment failure, and RASs could have an impact on the efficacy of a rescue treatment. Especially in countries with limited availability of VOX/VEL/SOF or G/P/SOF, different patterns of RAS persistence could have implications for retreatment with first-generation DAAs and for global HCV elimination goals. The different patterns of RAS persistence identified in this study can be used to derive general rules regarding the persistence of RASs after DAA failure that could be applied by physicians in less developed countries to plan individualized HCV retreatment

    Synthetic biology, inspired by synthetic chemistry

    Get PDF
    The topic synthetic biology appears still as an 'empty basket to be filled'. However, there is already plenty of claims and visions, as well as convincing research strategies about the theme of synthetic biology. First of all, synthetic biology seems to be about the engineering of biology -about bottom-up and top-down approaches, compromising complexity versus stability of artificial architectures, relevant in biology. Synthetic biology accounts for heterogeneous approaches towards minimal and even artificial life, the engineering of biochemical pathways on the organismic level, the modelling of molecular processes and finally, the combination of synthetic with nature-derived materials and architectural concepts, such as a cellular membrane. Still, synthetic biology is a discipline, which embraces interdisciplinary attempts in order to have a profound, scientific base to enable the re-design of nature and to compose architectures and processes with man-made matter. We like to give an overview about the developments in the field of synthetic biology, regarding polymer-based analogs of cellular membranes and what questions can be answered by applying synthetic polymer science towards the smallest unit in life, namely a cell. (C) 2012 Federation of European Biochemical Societies. Published by Elsevier B. V. All rights reserved
    corecore