20 research outputs found

    Inhomogeneous States in a Small Magnetic Disk with Single-Ion Surface Anisotropy

    Full text link
    We investigate analytically and numerically the ground and metastable states for easy-plane Heisenberg magnets with single-ion surface anisotropy and disk geometry. The configurations with two half-vortices at the opposite points of the border are shown to be preferable for strong anisotropy. We propose a simple analytical description of the spin configurations for all values of a surface anisotropy. The effects of lattice pinning leads to appearance of a set of metastable configurations.Comment: 10 pages, 7 figures; submitted to Phys. Rev.

    Tau Ori and Tau Lib: Two New Massive Heartbeat Binaries

    Get PDF
    We report the discovery of two massive eccentric systems with BRITE data, tau Ori and tau Lib, showing heartbeat effects close to the periastron passage. τ Lib exhibits shallow eclipses that will soon vanish due to the apsidal motion in the system. In neither system, tidally excited oscillations were detected

    Search for jet extinction in the inclusive jet-pT spectrum from proton-proton collisions at s=8 TeV

    Get PDF
    Published by the American Physical Society under the terms of the Creative Commons Attribution 3.0 License. Further distribution of this work must maintain attribution to the author(s) and the published articles title, journal citation, and DOI.The first search at the LHC for the extinction of QCD jet production is presented, using data collected with the CMS detector corresponding to an integrated luminosity of 10.7  fb−1 of proton-proton collisions at a center-of-mass energy of 8 TeV. The extinction model studied in this analysis is motivated by the search for signatures of strong gravity at the TeV scale (terascale gravity) and assumes the existence of string couplings in the strong-coupling limit. In this limit, the string model predicts the suppression of all high-transverse-momentum standard model processes, including jet production, beyond a certain energy scale. To test this prediction, the measured transverse-momentum spectrum is compared to the theoretical prediction of the standard model. No significant deficit of events is found at high transverse momentum. A 95% confidence level lower limit of 3.3 TeV is set on the extinction mass scale

    Searches for electroweak neutralino and chargino production in channels with Higgs, Z, and W bosons in pp collisions at 8 TeV

    Get PDF
    Searches for supersymmetry (SUSY) are presented based on the electroweak pair production of neutralinos and charginos, leading to decay channels with Higgs, Z, and W bosons and undetected lightest SUSY particles (LSPs). The data sample corresponds to an integrated luminosity of about 19.5 fb(-1) of proton-proton collisions at a center-of-mass energy of 8 TeV collected in 2012 with the CMS detector at the LHC. The main emphasis is neutralino pair production in which each neutralino decays either to a Higgs boson (h) and an LSP or to a Z boson and an LSP, leading to hh, hZ, and ZZ states with missing transverse energy (E-T(miss)). A second aspect is chargino-neutralino pair production, leading to hW states with E-T(miss). The decays of a Higgs boson to a bottom-quark pair, to a photon pair, and to final states with leptons are considered in conjunction with hadronic and leptonic decay modes of the Z and W bosons. No evidence is found for supersymmetric particles, and 95% confidence level upper limits are evaluated for the respective pair production cross sections and for neutralino and chargino mass values

    Accessory Transversarium Foramen of Cervical Vertebrae: A Case Study

    No full text
    The anatomical variations of the cervical vertebrae as reported in most classical anatomical textbooks mainly include: cervical ribs, non fusion of the halves of the posterior arch of the atlas, presence of articular facets on the superior margin of the anterior arch of the atlas incase of presence of a third occipital condyle. A male cadaver preserved by means of the routine embalming techniques following the completion of dissection was used for bone maceration. The soft tissues were removed and the cervical vertebrae were studied for variations. The variations recorded in this study include the presence of accessory transverse foramina in the atlas, C5 and C6, The presence of an accessory foramen transversarium in the cervical vertebra is a rare variation. It narrowed the size of the real transverse process and this may result in pressure on the vertebral artery and the sympathetic plexus embedding it. Similarly the narrowing of the transverse foramen may result in formation of atheromatose plaque which may also result to thrombosis emboli or just reflex spasm. The implications of these variations in the anatomy of this region should be noted by neurologist and by those who advocate instrumentation of the cervical vertebrae.Key words: Cervical vertebra, Atlas, Accessory transverse foramina, Foramen transversariu

    Life-cycle Dependency of Models for Product Development Processes

    No full text

    Design(er) support based on conceptual frameworks

    No full text

    Electrochemical and Crystallographic Aspects of Lead Granular Growth

    No full text
    Lead granules synthesized by the potentiostatic regime of electrolysis were characterized by the scanning electron microscopy technique. Effect of the different parameters of electrolysis, such as solution composition, overpotential of electrodeposition, and quantity of the electricity, on lead granular growth has been systematically investigated. Aside from the electrochemical aspects of lead granular growth, crystallographic aspects of the obtained granules were also analyzed. In the dependence of the electrodeposition conditions, granules of various shapes were obtained. The granules, such as octahedrons and hexagons, as well as many various types of twinned particles: single-twinned, multiply-twinned, lamellar-twinned, and many other complicated shapes denoted as polyparticles, were synthesized through regulation of the parameters of electrolysis. Increasing both the concentration of Pb2+ ions and overpotential of the electrodeposition favored the formation of more complicated forms. Formation of granules of specified crystallographic characteristics was also correlated with the basic principle of metal electrocrystallization

    Safety and efficacy of non-steroidal anti-inflammatory drugs to reduce ileus after colorectal surgery

    No full text
    Background: Ileus is common after elective colorectal surgery, and is associated with increased adverse events and prolonged hospital stay. The aim was to assess the role of non-steroidal anti-inflammatory drugs (NSAIDs) for reducing ileus after surgery. Methods: A prospective multicentre cohort study was delivered by an international, student- and trainee-led collaborative group. Adult patients undergoing elective colorectal resection between January and April 2018 were included. The primary outcome was time to gastrointestinal recovery, measured using a composite measure of bowel function and tolerance to oral intake. The impact of NSAIDs was explored using Cox regression analyses, including the results of a centre-specific survey of compliance to enhanced recovery principles. Secondary safety outcomes included anastomotic leak rate and acute kidney injury. Results: A total of 4164 patients were included, with a median age of 68 (i.q.r. 57\u201375) years (54\ub79 per cent men). Some 1153 (27\ub77 per cent) received NSAIDs on postoperative days 1\u20133, of whom 1061 (92\ub70 per cent) received non-selective cyclo-oxygenase inhibitors. After adjustment for baseline differences, the mean time to gastrointestinal recovery did not differ significantly between patients who received NSAIDs and those who did not (4\ub76 versus 4\ub78 days; hazard ratio 1\ub704, 95 per cent c.i. 0\ub796 to 1\ub712; P = 0\ub7360). There were no significant differences in anastomotic leak rate (5\ub74 versus 4\ub76 per cent; P = 0\ub7349) or acute kidney injury (14\ub73 versus 13\ub78 per cent; P = 0\ub7666) between the groups. Significantly fewer patients receiving NSAIDs required strong opioid analgesia (35\ub73 versus 56\ub77 per cent; P < 0\ub7001). Conclusion: NSAIDs did not reduce the time for gastrointestinal recovery after colorectal surgery, but they were safe and associated with reduced postoperative opioid requirement
    corecore