1,010 research outputs found
Reproducibility of patient setup by surface image registration system in conformal radiotherapy of prostate cancer
<p>Abstract</p> <p>Background</p> <p>The reproducibility of patient setup for radiotherapy is based on various methods including external markers, X-rays with planar or computerized image acquisition, and, more recently, surface matching imaging. We analyzed the setup reproducibility of 16 patients affected by prostate cancer who underwent conformal radiotherapy with curative intent by using a surface image registration system.</p> <p>Methods</p> <p>We analyzed the setup reproducibility of 16 patients affected by prostate cancer candidates for conformal radiotherapy by using a surface image registration system. At the initial setup, EPID images were compared with DRRs and a reference 3D surface image was obtained by the AlignRT system (Vision RT, London, UK). Surface images were acquired prior to every subsequent setup procedure. EPID acquisition was repeated when errors > 5 mm were reported.</p> <p>Results</p> <p>The mean random and systematic errors were 1.2 ± 2.3 mm and 0.3 ± 3.0 mm along the X axis, 0.0 ± 1.4 mm and 0.5 ± 2.0 mm along the Y axis, and 2.0 ± 1.8 mm and -0.7 ± 2.4 mm along the Z axis respectively. The positioning error detected by AlignRT along the 3 axes X, Y, and Z exceeded the value of 5 mm in 14.1%, 2.0%, and 5.1% measurements and the value of 3 mm in 36.9%, 13.6% and 27.8% measurements, respectively. Correlation factors calculated by linear regression between the errors measured by AlignRT and EPID ranged from 0.77 to 0.92 with a mean of 0.85 and SD of 0.13. The setup measurements by surface imaging are highly reproducible and correlate with the setup errors detected by EPID.</p> <p>Conclusion</p> <p>Surface image registration system appears to be a simple, fast, non-invasive, and reproducible method to analyze the set-up alignment in 3DCRT of prostate cancer patients.</p
Quantitative assessment of microbicide-induced injury in the ovine vaginal epithelium using confocal microendoscopy
<p>Abstract</p> <p>Background</p> <p>The development of safe topical microbicides that can preserve the integrity of cervicovaginal tract epithelial barrier is of great interest as this may minimize the potential for increased susceptibility to STI infections. High resolution imaging to assess epithelial integrity in a noninvasive manner could be a valuable tool for preclinical testing of candidate topical agents.</p> <p>Methods</p> <p>A quantitative approach using confocal fluorescence microendoscopy (CFM) for assessment of microbicide-induced injury to the vaginal epithelium was developed. Sheep were treated intravaginally with one of five agents in solution (PBS; 0.02% benzalkonium chloride (BZK); 0.2% BZK) or gel formulation (hydroxyethyl cellulose (HEC); Gynol II nonoxynol-9 gel (N-9)). After 24 hours the vaginal tract was removed, labeled with propidium iodide (PI), imaged, then fixed for histology. An automated image scoring algorithm was developed for quantitative assessment of injury and applied to the data set. Image-based findings were validated with histological visual gradings that describe degree of injury and measurement of epithelial thickness.</p> <p>Results</p> <p>Distinct differences in PI staining were detected following BZK and N-9 treatment. Images from controls had uniformly distributed nuclei with defined borders, while those after BZK or N-9 showed heavily stained and disrupted nuclei, which increased in proportion to injury detected on histology. The confocal scoring system revealed statistically significant scores for each agent versus PBS controls with the exception of HEC and were consistent with histology scores of injury.</p> <p>Conclusions</p> <p>Confocal microendoscopy provides a sensitive, objective, and quantitative approach for non-invasive assessment of vaginal epithelial integrity and could serve as a tool for real-time safety evaluation of emerging intravaginal topical agents.</p
Visualizing peripheral nerve regeneration by whole mount staining.
Peripheral nerve trauma triggers a well characterised sequence of events both proximal and distal to the site of injury. Axons distal to the injury degenerate, Schwann cells convert to a repair supportive phenotype and macrophages enter the nerve to clear myelin and axonal debris. Following these events, axons must regrow through the distal part of the nerve, re-innervate and finally are re-myelinated by Schwann cells. For nerve crush injuries (axonotmesis), in which the integrity of the nerve is maintained, repair may be relatively effective whereas for nerve transection (neurotmesis) repair will likely be very poor as few axons may be able to cross between the two parts of the severed nerve, across the newly generated nerve bridge, to enter the distal stump and regenerate. Analysing axon growth and the cell-cell interactions that occur following both nerve crush and cut injuries has largely been carried out by staining sections of nerve tissue, but this has the obvious disadvantage that it is not possible to follow the paths of regenerating axons in three dimensions within the nerve trunk or nerve bridge. To try and solve this problem, we describe the development and use of a novel whole mount staining protocol that allows the analysis of axonal regeneration, Schwann cell-axon interaction and re-vascularisation of the repairing nerve following nerve cut and crush injuries
Variations in Healthcare Access and Utilization Among Mexican Immigrants: The Role of Documentation Status
The objective of this study is to identify differences in healthcare access and utilization among Mexican immigrants by documentation status. Cross-sectional survey data are analyzed to identify differences in healthcare access and utilization across Mexican immigrant categories. Multivariable logistic regression and the Blinder-Oaxaca decomposition are used to parse out differences into observed and unobserved components. Mexican immigrants ages 18 and above who are immigrants of California households and responded to the 2007 California Health Interview Survey (2,600 documented and 1,038 undocumented immigrants). Undocumented immigrants from Mexico are 27% less likely to have a doctor visit in the previous year and 35% less likely to have a usual source of care compared to documented Mexican immigrants after controlling for confounding variables. Approximately 88% of these disparities can be attributed to predisposing, enabling and need determinants in our model. The remaining disparities are attributed to unobserved heterogeneity. This study shows that undocumented immigrants from Mexico are much less likely to have a physician visit in the previous year and a usual source of care compared to documented immigrants from Mexico. The recently approved Patient Protection and Affordable Care Act will not reduce these disparities unless undocumented immigrants are granted some form of legal status
L-Glutamine therapy reduces endothelial adhesion of sickle red blood cells to human umbilical vein endothelial cells
BACKGROUND: We have previously demonstrated that therapy with orally administered L-glutamine improves nicotinamide adenosine dinucleotide (NAD) redox potential of sickle red blood cells (RBC). On further analysis of L-glutamine therapy for sickle cell anemia patients, the effect of L-glutamine on adhesion of sickle RBC to human umbilical vein endothelial cells (HUVEC) was examined. METHODS: The first part of the experiment was conducted with the blood samples of the 5 adult sickle cell anemia patients who had been on L-glutamine therapy for at least 4 weeks on a dosage of 30 grams per day compared to those of patient control group. In the second part of the experiment 6 patients with sickle cell anemia were studied longitudinally. Five of these patients were treated with oral L-glutamine 30 grams daily and one was observed without treatment as the control. t-test and paired t-test were used for determination of statistical significance in cross-sectional and longitudinal studies respectively. RESULTS: In the first study, the mean adhesion to endothelial cells with the autologous plasma incubated cells were 0.97 ± 0.45 for the treated group and 1.91 ± 0.53 for the nontreated group (p < 0.02). Similarly with lipopolysaccharide (LPS) incubated cells the mean adhesion to endothelial cells were 1.39 ± 0.33 for the treated group and 2.80 ± 0.47 for the untreated group (p < 0.001). With the longitudinal experiment, mean decrease in the adhesion to endothelial cells was 1.13 ± 0.21 (p < 0.001) for the 5 treated patients whereas the control patient had slight increase in the adhesion to endothelial cells. CONCLUSION: In these studies, oral L-glutamine administration consistently resulted in improvement of sickle RBC adhesion to HUVEC. These data suggest positive physiological effects of L-glutamine in sickle cell disease
Effective Rheology of Bubbles Moving in a Capillary Tube
We calculate the average volumetric flux versus pressure drop of bubbles
moving in a single capillary tube with varying diameter, finding a square-root
relation from mapping the flow equations onto that of a driven overdamped
pendulum. The calculation is based on a derivation of the equation of motion of
a bubble train from considering the capillary forces and the entropy production
associated with the viscous flow. We also calculate the configurational
probability of the positions of the bubbles.Comment: 4 pages, 1 figur
Measurement of the Forward-Backward Asymmetry in the B -> K(*) mu+ mu- Decay and First Observation of the Bs -> phi mu+ mu- Decay
We reconstruct the rare decays , , and in a data sample
corresponding to collected in collisions at
by the CDF II detector at the Fermilab Tevatron
Collider. Using and decays we report the branching ratios. In addition, we report
the measurement of the differential branching ratio and the muon
forward-backward asymmetry in the and decay modes, and the
longitudinal polarization in the decay mode with respect to the squared
dimuon mass. These are consistent with the theoretical prediction from the
standard model, and most recent determinations from other experiments and of
comparable accuracy. We also report the first observation of the {\mathcal{B}}(B^0_s \to
\phi\mu^+\mu^-) = [1.44 \pm 0.33 \pm 0.46] \times 10^{-6}27 \pm 6B^0_s$ decay observed.Comment: 7 pages, 2 figures, 3 tables. Submitted to Phys. Rev. Let
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Measurements of the properties of Lambda_c(2595), Lambda_c(2625), Sigma_c(2455), and Sigma_c(2520) baryons
We report measurements of the resonance properties of Lambda_c(2595)+ and
Lambda_c(2625)+ baryons in their decays to Lambda_c+ pi+ pi- as well as
Sigma_c(2455)++,0 and Sigma_c(2520)++,0 baryons in their decays to Lambda_c+
pi+/- final states. These measurements are performed using data corresponding
to 5.2/fb of integrated luminosity from ppbar collisions at sqrt(s) = 1.96 TeV,
collected with the CDF II detector at the Fermilab Tevatron. Exploiting the
largest available charmed baryon sample, we measure masses and decay widths
with uncertainties comparable to the world averages for Sigma_c states, and
significantly smaller uncertainties than the world averages for excited
Lambda_c+ states.Comment: added one reference and one table, changed order of figures, 17
pages, 15 figure
- …