409 research outputs found

    Determinación de la calidad del aceite de té mediante 19F RMN y 1H RMN

    Get PDF
    The nuclear magnetic resonance (NMR) technique was applied to monitor the quality of tea oil herein. The adulteration of virgin tea oil was monitored by 19F NMR and 1H NMR. The 19F NMR technique was used as a new method to detect the changes in quality and hydroperoxide value of tea oil. The research demonstrates that 19F NMR and 1H NMR can quickly detect adulteration in tea oil. High temperature caused a decrease in the ratio D and increase in the total diglyceride content. Some new peaks belonging to the derivatives of hydroperoxides appeared at δ-108.21 and δ-109.05 ppm on the 19F NMR spectrum when the oil was autoxidized and became larger when the hydroperoxide value increased. These results have great significance in monitoring the moisture content, freshness and oxidation status of oils and in detecting adulteration in high priced edible oils by mixing with cheap oils.En este trabajo se utiliza la técnica de resonancia magnética nuclear (RMN) para controlar la calidad del aceite de té. La adulteración del aceite de té virgen se controló mediante las técnicas de 19F RMN y 1H RMN. La técnica de 19F RMN se utilizó como un nuevo método para detectar los cambios en la calidad y el índice de hidroperóxido del aceite de té. La investigación demuestra que las técnicas 19F RMN y 1H RMN pueden detectar rápidamente la adulteración del aceite de té. La alta temperatura provoca una disminución en la proporción D y un aumento en el contenido total de diglicéridos. Algunos picos nuevos, pertenecientes a derivados de hidroperóxidos, aparecieron a δ-108,21 y δ-109,05 ppm en el espectro de 19F RMN cuando el aceite se autoxidaba e incrementaban cuando aumentaba el índice de hidroperóxido. Estos resultados tienen gran importancia en el seguimiento del contenido de humedad, de la frescura y del estado de oxidación de los aceites y en la detección de la adulteración de aceites comestibles de alto valor con aceites baratos mediante el uso de 19F RMN y 1H RMN

    A simulated investigation on the machining instability and dynamic surface generation

    Get PDF
    In this paper, the authors propose the generic concept of machining instability based on the analysis of all kinds of machining instable behaviors and their features. The investigation covers all aspects of the machining process, including the machine tool structural response, cutting process variables, tooling geometry and workpiece material property in a full dynamic scenario. The paper presents a novel approach for coping with the sophisticated machining instability and enabling better understanding of its effect on the surface generation through a combination of the numerical method with the characteristic equations and using block diagrams/functions to represent implicit equations and nonlinear factors. It therefore avoids the lengthy algebraic manipulations in deriving the outcome and the solution scheme is thus simple, robust and intuitive. Several machining case studies and their simulation results demonstrate the proposed approach is feasible for shop floor CNC machining optimisation in particular. The results also indicate the proposed approach is useful to monitor the machining instability and surface topography and to be potentially applied in adaptive control of the instability in real time

    High Altitude test of RPCs for the ARGO-YBJ experiment

    Get PDF
    A 50 m**2 RPC carpet was operated at the YangBaJing Cosmic Ray Laboratory (Tibet) located 4300 m a.s.l. The performance of RPCs in detecting Extensive Air Showers was studied. Efficiency and time resolution measurements at the pressure and temperature conditions typical of high mountain laboratories, are reported.Comment: 16 pages, 10 figures, submitted to Nucl. Instr. Met

    Molecular and functional expression of anion exchangers in cultured normal human nasal epithelial cells

    Get PDF
    AIMS: Anions have an important role in the regulation of airway surface liquid (ASL) volume, viscosity and pH. However, functional localization and regulation of anion exchangers (AEs) have not been clearly described. The aim of this study was to investigate the regulation of AE mRNA expression level in accordance with mucociliary differentiation and the functional expression of AEs cultured normal human nasal epithelial (NHNE) cells. METHODS: Nasal mucosal specimens from three patients are obtained and serially cultured cells are subjected to morphological examinations, RT-PCR, Western blot analysis and immunocytochemistry. AE activity is assessed by pHi measurements. RESULTS: Expression of ciliated cells on the apical membrane and expression of MUC5AC, a marker of mucous differentiation, increased with time. AE2 and SLC26A4 mRNA expression decreased as mucociliary differentiation progressed, and AE4, SLC26A7 and SLC26A8 mRNA expression increased on the 14th and 28th day after confluence. Accordingly, AE4 protein expression also progressively increased. AE activity in 100 mM K(+) buffer solutions was nearly twofold higher than that in 5 mM K(+) buffer solutions. Moreover, only luminal AE activity increased about fourfold over the control in the presence of 5 microM forskolin. In the presence of 100 microM adenosine-5'-triphosphate (ATP) which evokes intracellular calcium signalling through activation of purinergic receptors, only luminal AE activity was again significantly increased. On the other hand, 500 microM 4,4'-diisothiocyanostilbene-2,2'-disulfonic acid (DIDS), an inhibitor of most SLC4 and SLC26AE isoforms, nearly abolished AE activity in both luminal and basolateral membranes. We found that AE activity was affected by intracellular cAMP and calcium signalling in the luminal membrane and was DIDS-sensitive in both membranes of cultured NHNE cells. CONCLUSION: Our findings through molecular and functional studies using cultured NHNE cells suggest that AEs may have an important role in the regulation of ASL.ope

    Partial Wave Analysis of J/ψγ(K+Kπ+π)J/\psi \to \gamma (K^+K^-\pi^+\pi^-)

    Full text link
    BES data on J/ψγ(K+Kπ+π)J/\psi \to \gamma (K^+K^-\pi^+\pi^-) are presented. The KKˉK^*\bar K^* contribution peaks strongly near threshold. It is fitted with a broad 0+0^{-+} resonance with mass M=1800±100M = 1800 \pm 100 MeV, width Γ=500±200\Gamma = 500 \pm 200 MeV. A broad 2++2^{++} resonance peaking at 2020 MeV is also required with width 500\sim 500 MeV. There is further evidence for a 2+2^{-+} component peaking at 2.55 GeV. The non-KKˉK^*\bar K^* contribution is close to phase space; it peaks at 2.6 GeV and is very different from KKˉK^{*}\bar{K^{*}}.Comment: 15 pages, 6 figures, 1 table, Submitted to PL

    BESII Detector Simulation

    Full text link
    A Monte Carlo program based on Geant3 has been developed for BESII detector simulation. The organization of the program is outlined, and the digitization procedure for simulating the response of various sub-detectors is described. Comparisons with data show that the performance of the program is generally satisfactory.Comment: 17 pages, 14 figures, uses elsart.cls, to be submitted to NIM

    Time-integrated luminosity recorded by the BABAR detector at the PEP-II e+e- collider

    Get PDF
    This article is the Preprint version of the final published artcile which can be accessed at the link below.We describe a measurement of the time-integrated luminosity of the data collected by the BABAR experiment at the PEP-II asymmetric-energy e+e- collider at the ϒ(4S), ϒ(3S), and ϒ(2S) resonances and in a continuum region below each resonance. We measure the time-integrated luminosity by counting e+e-→e+e- and (for the ϒ(4S) only) e+e-→μ+μ- candidate events, allowing additional photons in the final state. We use data-corrected simulation to determine the cross-sections and reconstruction efficiencies for these processes, as well as the major backgrounds. Due to the large cross-sections of e+e-→e+e- and e+e-→μ+μ-, the statistical uncertainties of the measurement are substantially smaller than the systematic uncertainties. The dominant systematic uncertainties are due to observed differences between data and simulation, as well as uncertainties on the cross-sections. For data collected on the ϒ(3S) and ϒ(2S) resonances, an additional uncertainty arises due to ϒ→e+e-X background. For data collected off the ϒ resonances, we estimate an additional uncertainty due to time dependent efficiency variations, which can affect the short off-resonance runs. The relative uncertainties on the luminosities of the on-resonance (off-resonance) samples are 0.43% (0.43%) for the ϒ(4S), 0.58% (0.72%) for the ϒ(3S), and 0.68% (0.88%) for the ϒ(2S).This work is supported by the US Department of Energy and National Science Foundation, the Natural Sciences and Engineering Research Council (Canada), the Commissariat à l’Energie Atomique and Institut National de Physique Nucléaire et de Physiquedes Particules (France), the Bundesministerium für Bildung und Forschung and Deutsche Forschungsgemeinschaft (Germany), the Istituto Nazionale di Fisica Nucleare (Italy), the Foundation for Fundamental Research on Matter (The Netherlands), the Research Council of Norway, the Ministry of Education and Science of the Russian Federation, Ministerio de Ciencia e Innovación (Spain), and the Science and Technology Facilities Council (United Kingdom). Individuals have received support from the Marie-Curie IEF program (European Union) and the A.P. Sloan Foundation (USA)

    Measurement of the B0-anti-B0-Oscillation Frequency with Inclusive Dilepton Events

    Get PDF
    The B0B^0-Bˉ0\bar B^0 oscillation frequency has been measured with a sample of 23 million \B\bar B pairs collected with the BABAR detector at the PEP-II asymmetric B Factory at SLAC. In this sample, we select events in which both B mesons decay semileptonically and use the charge of the leptons to identify the flavor of each B meson. A simultaneous fit to the decay time difference distributions for opposite- and same-sign dilepton events gives Δmd=0.493±0.012(stat)±0.009(syst)\Delta m_d = 0.493 \pm 0.012{(stat)}\pm 0.009{(syst)} ps1^{-1}.Comment: 7 pages, 1 figure, submitted to Physical Review Letter

    ARGO-YBJ constraints on very high energy emission from GRBs

    Full text link
    The ARGO-YBJ (Astrophysical Radiation Ground-based Observatory at YangBaJing) experiment is designed for very high energy γ\gamma-astronomy and cosmic ray researches. Due to the full coverage of a large area (5600m25600 m^2) with resistive plate chambers at a very high altitude (4300 m a.s.l.), the ARGO-YBJ detector is used to search for transient phenomena, such as Gamma-ray bursts (GRBs). Because the ARGO-YBJ detector has a large field of view (\sim2 sr) and is operated with a high duty cycle (>>90%), it is well suited for GRB surveying and can be operated in searches for high energy GRBs following alarms set by satellite-borne observations at lower energies. In this paper, the sensitivity of the ARGO-YBJ detector for GRB detection is estimated. Upper limits to fluence with 99% confidence level for 26 GRBs inside the field of view from June 2006 to January 2009 are set in the two energy ranges 10-100 GeV and 10 GeV-1 TeV.Comment: accepted for publication in Astroparticle Physic
    corecore