425 research outputs found

    A Multicenter Study of Bacterial Vaginosis in Women With or at Risk for Human Immunodeficiency Virus Infection

    Get PDF
    Background: Bacterial vaginosis is a common gynecologic infection that has been associated with a variety of gynecologic and obstetric complications, including pelvic inflammatory disease, postabortal infection and premature delivery. Recent studies suggest that bacterial vaginosis may increase a woman’s risk for human immunodeficiency virus (HIV). We undertook this study to assess whether the prevalence and characteristics of bacterial vaginosis differed according to HIV status in high-risk US women. Methods: Prevalence of bacterial vaginosis was assessed by Gram’s stain and clinical criteria for 854 HIV-infected and 434 HIV-uninfected women enrolled in the HIV Epidemiology Research (HER) Study.Multiple logistic regression techniques were used to determine whether HIV infection independently predicted bacterial vaginosis. Results: Almost half (46%) the women had bacterial vaginosis by Gram’s stain. The prevalence of bacterial vaginosis was 47% in the HIV-positive women compared with 44% in the HIV-negativewomen; this difference was not statistically significant (p = 0.36). After adjustment for other covariates, HIV-positive women were more likely than HIV-negative women to have bacterial vaginosis (odds ratio (OR) 1.31; 95% confidence interval (CI) 1.01-1.70) by Gram's stain but not by clinical criteria (OR 1.16; CI 0.87-1.55). Among HIV-positive women, use of antiretroviral drugs was associated with a lower prevalence of bacterial vaginosis (adjusted OR 0.54; Cl 0.38 -0.77). Conclusions: In this cross-sectional analysis of high-risk US women, HIV infection was positively correlated with bacterial vaginosis diagnosed by Gram’s stain

    Plasmonic excitations in noble metals: The case of Ag

    Get PDF
    The delicate interplay between plasmonic excitations and interband transitions in noble metals is described by means of {\it ab initio} calculations and a simple model in which the conduction electron plasmon is coupled to the continuum of electron-hole pairs. Band structure effects, specially the energy at which the excitation of the dd-like bands takes place, determine the existence of a subthreshold plasmonic mode, which manifests itself in Ag as a sharp resonance at 3.8 eV. However, such a resonance is not observed in the other noble metals. Here, this different behavior is also analyzed and an explanation is provided.Comment: 9 pages, 8 figure

    An Insight Into Cervical Cancer Screening and Treatment Capacity in Sub Saharan Africa.

    Get PDF
    OBJECTIVE Approximately 85% of cervical cancer cases and deaths occur in resource-constrained countries where best practices for prevention, particularly for women with HIV infection, still need to be developed. The aim of this study was to assess cervical cancer prevention capacity in select HIV clinics located in resource-constrained countries. MATERIALS AND METHODS A cross-sectional survey of sub-Saharan African sites of 4 National Institutes of Health-funded HIV/AIDS networks was conducted. Sites were surveyed on the availability of cervical cancer screening and treatment among women with HIV infection and without HIV infection. Descriptive statistics and χ or Fisher exact test were used as appropriate. RESULTS Fifty-one (65%) of 78 sites responded. Access to cervical cancer screening was reported by 49 sites (96%). Of these sites, 39 (80%) performed screening on-site. Central African sites were less likely to have screening on-site (p = .02) versus other areas. Visual inspection with acetic acid and Pap testing were the most commonly available on-site screening methods at 31 (79%) and 26 (67%) sites, respectively. High-risk HPV testing was available at 29% of sites with visual inspection with acetic acid and 50% of sites with Pap testing. Cryotherapy and radical hysterectomy were the most commonly available on-site treatment methods for premalignant and malignant lesions at 29 (74%) and 18 (46%) sites, respectively. CONCLUSIONS Despite limited resources, most sites surveyed had the capacity to perform cervical cancer screening and treatment. The existing infrastructure of HIV clinical and research sites may provide the ideal framework for scale-up of cervical cancer prevention in resource-constrained countries with a high burden of cervical dysplasia

    Diagnostic performance of contrast enhanced CT and 18F-FDG PET/CT in suspicious recurrence of biliary tract cancer after curative resection

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Because of the late clinical presentation of biliary tract cancer (BTC), only 10% of patients are eligible for curative surgery. Even among those patients who have undergone curative surgery, most patients develop recurrent cancer. This study is to determine the clinical role of <sup>18</sup>F-FDG PET/CT during post-operative surveillance of suspected recurrent BTC based on symptoms, laboratory findings and contrast-enhanced CT (ceCT) findings.</p> <p>Methods</p> <p>We consecutively enrolled 50 patients with BTC who underwent curative surgery. An <sup>18</sup>F-FDG PET/CT was obtained for assessment of recurrence based on clinical suspicion during post-operative surveillance. The final confirmation of recurrence was determined pathologically or clinically. When a pathologic confirmation was impossible or inconclusive, a clinical confirmation was used by radiologic correlation with subsequent follow-up ceCT at a minimum of 3-month intervals. Diagnostic efficacy was evaluated by comparing the results of ceCT and <sup>18</sup>F-FDG PET/CT with the final diagnosis.</p> <p>Results</p> <p>Among the 50 patients, 34(68%) were confirmed to have a recurrence. PET/CT showed higher sensitivity (88% <it>vs</it>. 76%, <it>p </it>= 0.16) and accuracy (82% <it>vs</it>. 66%, <it>p </it>= 0.11) for recurrence compared to ceCT, even though the difference was not significant. The positive (86% <it>vs</it>. 74%, <it>p </it>= 0.72) and negative predictive values for recurrence (73% <it>vs</it>. 47%, <it>p </it>= 0.55) were not significantly different between PET/CT and ceCT. However, an additional PET/CT on ceCT significantly improved the sensitivity than did a ceCT alone (94% [32/34] for PET/CT on ceCT <it>vs</it>. 76% [26/34] for ceCT alone, <it>p </it>= 0.03) without increasing the specificity, positive predictive value, and negative predictive value.</p> <p>Conclusions</p> <p><sup>18</sup>F-FDG PET/CT alone is not more sensitive or specific than ceCT in the detection of recurrent BTC after curative surgery. These results do not reach statistical significance, probably due to the low number of patients. However, an additional <sup>18</sup>F-FDG PET/CT on ceCT significantly improves the sensitivity of detecting recurrences.</p

    Doppler ultrasound in the measurement of pulse wave velocity: agreement with the Complior method

    Get PDF
    Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for the measurement of aortic PWV

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≄20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≀pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≀{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration

    Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector

    Get PDF
    The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb^-1. The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet cross-section is measured as a function of the dijet invariant mass in the range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets and the angular variable chi in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final version published in European Physical Journal

    Antipsychotic prescribing for vulnerable populations: a clinical audit at an acute Australian mental health unit at two-time points

    Get PDF
    Background: Antipsychotics are recognised as a critical intervention for schizophrenia and bipolar disorder. Guidelines globally endorse the routine practice of antipsychotic monotherapy, at the minimum effective dose. Even in treatmentresistant schizophrenia, clozapine use is endorsed before combining antipsychotics. This aim of this study was to review antipsychotic polytherapy alone, high-dose therapy alone, polytherapy and highdose prescribing patterns in adults discharged from an inpatient mental health unit at two time-points, and the alignment of this prescribing with clinical guideline recommendations. Additionally, associations with polytherapy and high-dose antipsychotic prescribing, including patient and clinical characteristics, were explored. Methods: A retrospective clinical audit of 400 adults (200 patients at two different time-points) discharged with at least one antipsychotic. Preliminary findings and education sessions were provided to physicians between Cohorts. Outcomes (polytherapy alone, high-dose therapy alone, polytherapy and high-dose therapy) were compared between study Cohorts using chi-squared and rank-sum tests. Associations between outcomes and covariates were assessed using multivariable logistic regression. Results: Most patients (62.5%) were discharged on a single antipsychotic within the recommended dose range. There was a clear preference for prescribing second generation antipsychotics, and in this respect, prescribing is aligned with current evidence-based guidelines. However, sub-optimal prescribing practices were identified for both Cohorts in relation to polytherapy and high-dose antipsychotic rates. Involuntary treatment, frequent hospitalisations and previous clozapine use significantly increased the risk of all three prescribing outcomes at discharge. Conclusions: In a significant minority, antipsychotic prescribing did not align with clinical guidelines despite increased training, indicating that the education program alone was ineffective at positively influencing antipsychotic prescribing practices. Further consideration should be given when prescribing antipsychotics for involuntary patients, people with frequent hospitalisations, and those who have previously trialled clozapine

    Total energy expenditure is repeatable in adults but not associated with short-term changes in body composition

    Get PDF
    Low total energy expenditure (TEE, MJ/d) has been a hypothesized risk factor for weight gain, but repeatability of TEE, a critical variable in longitudinal studies of energy balance, is understudied. We examine repeated doubly labeled water (DLW) measurements of TEE in 348 adults and 47 children from the IAEA DLW Database (mean ± SD time interval: 1.9 ± 2.9 y) to assess repeatability of TEE, and to examine if TEE adjusted for age, sex, fat-free mass, and fat mass is associated with changes in weight or body composition. Here, we report that repeatability of TEE is high for adults, but not children. Bivariate Bayesian mixed models show no among or within-individual correlation between body composition (fat mass or percentage) and unadjusted TEE in adults. For adults aged 20-60 y (N = 267; time interval: 7.4 ± 12.2 weeks), increases in adjusted TEE are associated with weight gain but not with changes in body composition; results are similar for subjects with intervals >4 weeks (N = 53; 29.1 ± 12.8 weeks). This suggests low TEE is not a risk factor for, and high TEE is not protective against, weight or body fat gain over the time intervals tested
    • 

    corecore