482 research outputs found

    MOLEC: Anywhere and at Any Time Arrhythmia Classification

    Get PDF
    The new advances in sensor technology, PDAs and wireless communications favor the development of a new type of monitoring systems that can provide patients with assistance anywhere and at any time. Of particular interest are the monitoring systems designed for people that suffer from heart arrhythmias, due to the increasing number of people with cardiovascular diseases. In this paper, we present MOLEC: a PDA-based system that performs local real-time classification and detects the ECG anomalies in situ. In the actual implementation of MOLEC, the signal is acquired by some ECG sensors (ActiveECG sensors) with a 360Hz frequency. For the preprocessing of the signal the ECGPUWAVE tool and an automata developed by us that identifies the beats are used. We have also developed a beat and rhythm classifiers that determine if there has been an anomalous rhythm, and in that case, an alarm is sent to a hospital via wireless communications. The rhythm detection delay of the MOLEC system is of 6.66 seconds. classifier that can run in real-time into a PDA. In this paper we show first the framework of the system, then in section 3 the process that we followed in order to select a beat and rhythm classifier that provides an accuracy result and in section 4 we show some performance aspects considering PDAs resources. 2. Framework of the MOLEC system In this section we explain the four components that form the global architecture of MOLEC (see figure 1): the ECG sensor, the Monitor Molec, Molec Center and the users of the system (hospital and relative computers). 1

    Analysis of Error in the Estimation of the Temporal ACF of Ergodic Sum-of-Cisoids Simulators for Mobile Fading Channels

    Get PDF
    Abstract-Mobile fading channel simulators based on ergodic sum-of-cisoids (SOC) processes have been proposed in several papers as a solution to accurately approximate the channel's autocorrelation function (ACF) in a single simulation run. However, despite the encouraging results presented in the literature, it is not clear whether the ergodicity of this type of simulators is meaningful in practice, where in contrast to what theory assumes, the waveforms generated by the simulator have finite lengths. To clarifying this issue, we present in this paper a comprehensive analysis of the random error observed when the temporal ACF (TACF) of ergodic SOC processes is estimated from waveforms of finite duration. We start by computing the instantaneous error produced by three different estimators, namely the biased, the unbiased, and the half-interval estimators. We then derive compact expressions for some insightful statistical quantities of the estimation error, such as the mean, the variance, and the mean-squared value. Based on the obtained results, we discuss the conditions under which an ergodic SOC simulator can be considered to perform similarly in theory and practice. The analysis presented in this paper can be used as a framework for testing, calibration, and performance validation of new ergodic SOC channel simulators

    Use of sonic tomography to detect and quantify wood decay in living trees.

    Get PDF
    Premise of the studyField methodology and image analysis protocols using acoustic tomography were developed and evaluated as a tool to estimate the amount of internal decay and damage of living trees, with special attention to tropical rainforest trees with irregular trunk shapes.Methods and resultsLiving trunks of a diversity of tree species in tropical rainforests in the Republic of Panama were scanned using an Argus Electronic PiCUS 3 Sonic Tomograph and evaluated for the amount and patterns of internal decay. A protocol using ImageJ analysis software was used to quantify the proportions of intact and compromised wood. The protocols provide replicable estimates of internal decay and cavities for trees of varying shapes, wood density, and bark thickness.ConclusionsSonic tomography, coupled with image analysis, provides an efficient, noninvasive approach to evaluate decay patterns and structural integrity of even irregularly shaped living trees

    Age-Related Differences in Ocular Features of a Naturalistic Free-Ranging Population of Rhesus Macaques

    Get PDF
    This is the final version. Available on open access from the Association for Research in Vision and Ophthalmology via the DOI in this recordPURPOSE: Rhesus macaques (Macaca mulatta) are the premier nonhuman primate model for studying human health and disease. We investigated if age was associated with clinically relevant ocular features in a large cohort of free-ranging rhesus macaques from Cayo Santiago, Puerto Rico. METHODS: We evaluated 120 rhesus macaques (73 males, 47 females) from 0 to 29 years old (mean ± SD: 12.6 ± 6.4) from September to December 2021. The ophthalmic evaluation included intraocular pressure (IOP) assessment, corneal pachymetry, biomicroscopy, A-scan biometry, automated refraction, and fundus photography after pupil dilation. The associations of age with the outcomes were investigated through multilevel mixed-effects models adjusted for sex and weight. RESULTS: On average, IOP, pachymetry, axial length, and automated refraction spherical equivalent were 18.37 ± 4.68 mmHg, 474.43 ± 32.21 µm, 19.49 ± 1.24 mm, and 0.30 ± 1.70 diopters (D), respectively. Age was significantly associated with pachymetry (β coefficient = -1.20; 95% confidence interval [CI], -2.27 to -0.14; P = 0.026), axial length (β coefficient = 0.03; 95% CI, 0.01 to 0.05; P = 0.002), and spherical equivalent (β coefficient = -0.12; 95% CI, -0.22 to -0.02; P = 0.015). No association was detected between age and IOP. The prevalence of cataracts in either eye was 10.83% (95% CI, 6.34-17.89) and was significantly associated with age (odds ratio [OR] = 1.20; 95% CI, 1.06-1.36; P = 0.004). Retinal drusen in either eye was observed in 15.00% (95% CI, 9.60-22.68) of animals, which was also significantly associated with age (OR = 1.14; 95% CI, 1.02-1.27; P = 0.020). CONCLUSIONS: Rhesus macaques exhibit age-related ocular associations similar to those observed in human aging, including decreased corneal thickness, increased axial length, myopic shift, and higher prevalence of cataract and retinal drusen.New Frontiers in Research FoundationNatural Sciences and Engineering Research CouncilCanada Research Chairs ProgramNational Aging InstituteBrightFocus FoundationNational Institutes of Health (NIH)University of Calgar

    A Randomized Trial of Convalescent Plasma in Covid-19 Severe Pneumonia

    Get PDF
    BACKGROUND:Convalescent plasma is frequently administered to patients with Covid-19 and hasbeen reported, largely on the basis of observational data, to improve clinical outcomes.Minimal data are available from adequately powered randomized, controlled trials. METHODS:We randomly assigned hospitalized adult patients with severe Covid-19 pneumoniain a 2:1 ratio to receive convalescent plasma or placebo. The primary outcome wasthe patient?s clinical status 30 days after the intervention, as measured on a six-pointordinal scale ranging from total recovery to death. RESULTS:A total of 228 patients were assigned to receive convalescent plasma and 105 toreceive placebo. The median time from the onset of symptoms to enrollment inthe trial was 8 days (interquartile range, 5 to 10), and hypoxemia was the mostfrequent severity criterion for enrollment. The infused convalescent plasma had amedian titer of 1:3200 of total SARS-CoV-2 antibodies (interquartile range, 1:800 to1:3200]. No patients were lost to follow-up. At day 30 day, no significant differencewas noted between the convalescent plasma group and the placebo group in thedistribution of clinical outcomes according to the ordinal scale (odds ratio, 0.83(95% confidence interval [CI], 0.52 to 1.35; P=0.46). Overall mortality was 10.96%in the convalescent plasma group and 11.43% in the placebo group, for a risk difference of −0.46 percentage points (95% CI, −7.8 to 6.8). Total SARS-CoV-2 antibodytiters tended to be higher in the convalescent plasma group at day 2 after the intervention. Adverse events and serious adverse events were similar in the two groups. CONCLUSIONS:no significant differences were observed in clinical status or overall mortality between patients treated with convalescent plasma and those who received placebo.(PlasmAr ClinicalTrials.gov number, NCT04383535.)Fil: Simonovich, Ventura A.. Hospital Italiano. Departamento de Medicina. Servicio de Clinica Medica.; ArgentinaFil: Burgos Pratx, Leandro D.. Hospital Italiano. Departamento de Medicina. Servicio de Clinica Medica.; ArgentinaFil: Scibona, Paula. Hospital Italiano. Departamento de Medicina. Servicio de Clinica Medica.; ArgentinaFil: Beruto, Maria Valeria. No especifíca;Fil: Vallone, Miguel Gabriel. No especifíca;Fil: Vázquez, C.. No especifíca;Fil: Savoy, N.. No especifíca;Fil: Giunta, Diego Hernan. No especifíca;Fil: Pérez, L.G.. No especifíca;Fil: Sánchez, M.L.. No especifíca;Fil: Gamarnik, Andrea Vanesa. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Investigaciones Bioquímicas de Buenos Aires. Fundación Instituto Leloir. Instituto de Investigaciones Bioquímicas de Buenos Aires; ArgentinaFil: Ojeda, D.S.. No especifíca;Fil: Santoro, D.M.. No especifíca;Fil: Camino, P. J.. No especifíca;Fil: Antelo, S.. No especifíca;Fil: Rainero, K.. No especifíca;Fil: Vidiella, G. P.. No especifíca;Fil: Miyazaki, E. A.. No especifíca;Fil: Cornistein, W.. No especifíca;Fil: Trabadelo, O. A.. No especifíca;Fil: Ross, F. M.. No especifíca;Fil: Spotti, M.. No especifíca;Fil: Funtowicz, G.. No especifíca;Fil: Scordo, W. E.. No especifíca;Fil: Losso, M. H.. No especifíca;Fil: Ferniot, I.. No especifíca;Fil: Pardo, P. E.. No especifíca;Fil: Rodriguez, E.. No especifíca;Fil: Rucci, P.. No especifíca;Fil: Pasquali, J.. No especifíca;Fil: Fuentes, N. A.. No especifíca;Fil: Esperatti, M.. No especifíca;Fil: Speroni, G. A.. No especifíca;Fil: Nannini, Esteban. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Inmunología Clinica y Experimental de Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Médicas. Instituto de Inmunología Clinica y Experimental de Rosario; ArgentinaFil: Matteaccio, A.. No especifíca;Fil: Michelangelo, H.G.. No especifíca;Fil: Follmann, D.. No especifíca;Fil: Lane, H. Clifford. No especifíca;Fil: Belloso, Waldo Horacio. Hospital Italiano. Departamento de Medicina. Servicio de Clinica Medica.; Argentin

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Depletion of Human Histone H1 Variants Uncovers Specific Roles in Gene Expression and Cell Growth

    Get PDF
    At least six histone H1 variants exist in somatic mammalian cells that bind to the linker DNA and stabilize the nucleosome particle contributing to higher order chromatin compaction. In addition, H1 seems to be actively involved in the regulation of gene expression. However, it is not well known whether the different variants have distinct roles or if they regulate specific promoters. We have explored this by inducible shRNA-mediated knock-down of each of the H1 variants in a human breast cancer cell line. Rapid inhibition of each H1 variant was not compensated for by changes of expression of other variants. Microarray experiments have shown a different subset of genes to be altered in each H1 knock-down. Interestingly, H1.2 depletion caused specific effects such as a cell cycle G1-phase arrest, the repressed expression of a number of cell cycle genes, and decreased global nucleosome spacing. On its side, H1.4 depletion caused cell death in T47D cells, providing the first evidence of the essential role of an H1 variant for survival in a human cell type. Thus, specific phenotypes are observed in breast cancer cells depleted of individual histone H1 variants, supporting the theory that distinct roles exist for the linker histone variants
    corecore