NectarCAM : a camera for the medium size telescopes of the Cherenkov Telescope Array
NectarCAM is a camera proposed for the medium-sized telescopes of the
Cherenkov Telescope Array (CTA) covering the central energy range of ~100 GeV
to ~30 TeV. It has a modular design and is based on the NECTAr chip, at the
heart of which is a GHz sampling Switched Capacitor Array and a 12-bit Analog
to Digital converter. The camera will be equipped with 265 7-photomultiplier
modules, covering a field of view of 8 degrees. Each module includes the
photomultiplier bases, high voltage supply, pre-amplifier, trigger, readout and
Ethernet transceiver. The recorded events last between a few nanoseconds and
tens of nanoseconds. The camera trigger will be flexible so as to minimize the
read-out dead-time of the NECTAr chips. NectarCAM is designed to sustain a data
rate of more than 4 kHz with less than 5\% dead time. The camera concept, the
design and tests of the various subcomponents and results of thermal and
electrical prototypes are presented. The design includes the mechanical
structure, cooling of the electronics, read-out, clock distribution, slow
control, data-acquisition, triggering, monitoring and services.Comment: In Proceedings of the 34th International Cosmic Ray Conference
(ICRC2015), The Hague, The Netherlands. All CTA contributions at
arXiv:1508.0589
The enhanced X-ray Timing and Polarimetry mission – eXTP: an update on its scientific cases, mission profile and development status
The enhanced X-ray Timing and Polarimetry mission (eXTP) is a flagship observatory for X-ray timing, spectroscopy and polarimetry developed by an International Consortium. Thanks to its very large collecting area, good spectral resolution and unprecedented polarimetry capabilities, eXTP will explore the properties of matter and the propagation of light in the most extreme conditions found in the Universe. eXTP will, in addition, be a powerful X-ray observatory. The mission will continuously monitor the X-ray sky, and will enable multiwavelength and multi-messenger studies. The mission is currently in phase B, which will be completed in the middle of 2022
The LOFT mission concept: a status update
The Large Observatory For x-ray Timing (LOFT) is a mission concept which was proposed to ESA as M3 and M4 candidate in the framework of the Cosmic Vision 2015-2025 program. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument and the uniquely large field of view of its wide field monitor, LOFT will be able to study the behaviour of matter in extreme conditions such as the strong gravitational field in the innermost regions close to black holes and neutron stars and the supra-nuclear densities in the interiors of neutron stars. The science payload is based on a Large Area Detector (LAD, >8m2 effective area, 2-30 keV, 240 eV spectral resolution, 1 degree collimated field of view) and a Wide Field Monitor (WFM, 2-50 keV, 4 steradian field of view, 1 arcmin source location accuracy, 300 eV spectral resolution). The WFM is equipped with an on-board system for bright events (e.g., GRB) localization. The trigger time and position of these events are broadcast to the ground within 30 s from discovery. In this paper we present the current technical and programmatic status of the mission
Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons
The Compact Muon Solenoid Collaboration is designing a new high-granularity
endcap calorimeter, HGCAL, to be installed later this decade. As part of this
development work, a prototype system was built, with an electromagnetic section
consisting of 14 double-sided structures, providing 28 sampling layers. Each
sampling layer has an hexagonal module, where a multipad large-area silicon
sensor is glued between an electronics circuit board and a metal baseplate. The
sensor pads of approximately 1 cm are wire-bonded to the circuit board and
are readout by custom integrated circuits. The prototype was extensively tested
with beams at CERN's Super Proton Synchrotron in 2018. Based on the data
collected with beams of positrons, with energies ranging from 20 to 300 GeV,
measurements of the energy resolution and linearity, the position and angular
resolutions, and the shower shapes are presented and compared to a detailed
Geant4 simulation
Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20300 GeV/c
The upgrade of the CMS experiment for the high luminosity operation of the
LHC comprises the replacement of the current endcap calorimeter by a high
granularity sampling calorimeter (HGCAL). The electromagnetic section of the
HGCAL is based on silicon sensors interspersed between lead and copper (or
copper tungsten) absorbers. The hadronic section uses layers of stainless steel
as an absorbing medium and silicon sensors as an active medium in the regions
of high radiation exposure, and scintillator tiles directly readout by silicon
photomultipliers in the remaining regions. As part of the development of the
detector and its readout electronic components, a section of a silicon-based
HGCAL prototype detector along with a section of the CALICE AHCAL prototype was
exposed to muons, electrons and charged pions in beam test experiments at the
H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology
as foreseen for the HGCAL but with much finer longitudinal segmentation. The
performance of the calorimeters in terms of energy response and resolution,
longitudinal and transverse shower profiles is studied using negatively charged
pions, and is compared to GEANT4 predictions. This is the first report
summarizing results of hadronic showers measured by the HGCAL prototype using
beam test data.Comment: To be submitted to JINS
ATHENA detector proposal - a totally hermetic electron nucleus apparatus proposed for IP6 at the Electron-Ion Collider
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity.This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges
Southern African Large Telescope Spectroscopy of BL Lacs for the CTA project
In the last two decades, very-high-energy gamma-ray astronomy has reached maturity: over 200 sources have been detected, both Galactic and extragalactic, by ground-based experiments. At present, Active Galactic Nuclei (AGN) make up about 40% of the more than 200 sources detected at very high energies with ground-based telescopes, the majority of which are blazars, i.e. their jets are closely aligned with the line of sight to Earth and three quarters of which are classified as high-frequency peaked BL Lac objects. One challenge to studies of the cosmological evolution of BL Lacs is the difficulty of obtaining redshifts from their nearly featureless, continuum-dominated spectra. It is expected that a significant fraction of the AGN to be detected with the future Cherenkov Telescope Array (CTA) observatory will have no spectroscopic redshifts, compromising the reliability of BL Lac population studies, particularly of their cosmic evolution. We started an effort in 2019 to measure the redshifts of a large fraction of the AGN that are likely to be detected with CTA, using the Southern African Large Telescope (SALT). In this contribution, we present two results from an on-going SALT program focused on the determination of BL Lac object redshifts that will be relevant for the CTA observatory
ATHENA detector proposal — a totally hermetic electron nucleus apparatus proposed for IP6 at the Electron-Ion Collider
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges
HGCROC2: the front-end readout ASICs for the CMS High Granularity Calorimeter
International audienceThe CMS High-Granularity Calorimeter (HGCAL) imposes extremely challenging specifications for the front-end electronics: high dynamic range, low noise, high-precision time information and low power consumption, as well as the need to select and transmit trigger information with a high transverse and longitudinal granularity. HGCROC2 is the second prototype of the readout chip embedding almost all the final functionalities. It has 72 channels of the full analog chain: low noise and high gain preamplifier and shapers, a 10-bit 40 MHz SAR-ADC which provides the charge measurement over the linear range of the preamplifier, after the preamplifier saturation a discriminator and TDC provide the charge information from ToT (200 ns dynamic range and 50 ps binning), and a fast discriminator and TDC provide timing information to 25 ps accuracy. This paper reports on the performance in terms of noise, charge and timing, the DAQ and Trigger paths, as well as results from radiation qualification with total ionizing dose (TID) and heavy ions for single-event effects (SEE)
- …