4,343 research outputs found

    Frequency Analysis of Atrial Fibrillation From the Surface Electrocardiogram

    Get PDF
    Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice. Neither the natural history of AF nor its response to therapy are sufficiently predictable by clinical and echocardiographic parameters. Atrial fibrillatory frequency (or rate) can reliably be assessed from the surface electrocardiogram (ECG) using digital signal processing (filtering, subtraction of averaged QRST complexes, and power spectral analysis) and shows large inter-individual variability. This measurement correlates well with intraatrial cycle length, a parameter which appears to have primary importance in AF domestication and response to therapy. AF with a low fibrillatory rate is more likely to terminate spontaneously, and responds better to antiarrhythmic drugs or cardioversion while high rate AF is more often persistent and refractory to therapy. In conclusion, frequency analysis of AF seems to be useful for non-invasive assessment of electrical remodeling in AF and may subsequently be helpful for guiding AF therapy

    Wavelet entropy as a measure of ventricular beat suppression from the electrocardiogram in atrial fibrillation

    Get PDF
    A novel method of quantifying the effectiveness of the suppression of ventricular activity from electrocardiograms (ECGs) in atrial fibrillation is proposed. The temporal distribution of the energy of wavelet coefficients is quantified by wavelet entropy at each ventricular beat. More effective ventricular activity suppression yields increased entropies at scales dominated by the ventricular and atrial components of the ECG. Two studies are undertaken to demonstrate the efficacy of the method: first, using synthesised ECGs with controlled levels of residual ventricular activity, and second, using patient recordings with ventricular activity suppressed by an average beat template subtraction algorithm. In both cases wavelet entropy is shown to be a good measure of the effectiveness of ventricular beat suppression

    Time series kernel similarities for predicting Paroxysmal Atrial Fibrillation from ECGs

    Get PDF
    We tackle the problem of classifying Electrocardiography (ECG) signals with the aim of predicting the onset of Paroxysmal Atrial Fibrillation (PAF). Atrial fibrillation is the most common type of arrhythmia, but in many cases PAF episodes are asymptomatic. Therefore, in order to help diagnosing PAF, it is important to design procedures for detecting and, more importantly, predicting PAF episodes. We propose a method for predicting PAF events whose first step consists of a feature extraction procedure that represents each ECG as a multi-variate time series. Successively, we design a classification framework based on kernel similarities for multi-variate time series, capable of handling missing data. We consider different approaches to perform classification in the original space of the multi-variate time series and in an embedding space, defined by the kernel similarity measure. We achieve a classification accuracy comparable with state of the art methods, with the additional advantage of detecting the PAF onset up to 15 minutes in advance

    Detection of atrial fibrillation episodes in long-term heart rhythm signals using a support vector machine

    Get PDF
    Atrial fibrillation (AF) is a serious heart arrhythmia leading to a significant increase of the risk for occurrence of ischemic stroke. Clinically, the AF episode is recognized in an electrocardiogram. However, detection of asymptomatic AF, which requires a long-term monitoring, is more efficient when based on irregularity of beat-to-beat intervals estimated by the heart rate (HR) features. Automated classification of heartbeats into AF and non-AF by means of the Lagrangian Support Vector Machine has been proposed. The classifier input vector consisted of sixteen features, including four coefficients very sensitive to beat-to-beat heart changes, taken from the fetal heart rate analysis in perinatal medicine. Effectiveness of the proposed classifier has been verified on the MIT-BIH Atrial Fibrillation Database. Designing of the LSVM classifier using very large number of feature vectors requires extreme computational efforts. Therefore, an original approach has been proposed to determine a training set of the smallest possible size that still would guarantee a high quality of AF detection. It enables to obtain satisfactory results using only 1.39% of all heartbeats as the training data. Post-processing stage based on aggregation of classified heartbeats into AF episodes has been applied to provide more reliable information on patient risk. Results obtained during the testing phase showed the sensitivity of 98.94%, positive predictive value of 98.39%, and classification accuracy of 98.86%.Web of Science203art. no. 76

    Exponential distribution of long heart beat intervals during atrial fibrillation and their relevance for white noise behaviour in power spectrum

    Full text link
    The statistical properties of heart beat intervals of 130 long-term surface electrocardiogram recordings during atrial fibrillation (AF) are investigated. We find that the distribution of interbeat intervals exhibits a characteristic exponential tail, which is absent during sinus rhythm, as tested in a corresponding control study with 72 healthy persons. The rate of the exponential decay lies in the range 3-12 Hz and shows diurnal variations. It equals, up to statistical uncertainties, the level of the previously uncovered white noise part in the power spectrum, which is also characteristic for AF. The overall statistical features can be described by decomposing the intervals into two statistically independent times, where the first one is associated with a correlated process with 1/f noise characteristics, while the second one belongs to an uncorrelated process and is responsible for the exponential tail. It is suggested to use the rate of the exponential decay as a further parameter for a better classification of AF and for the medical diagnosis. The relevance of the findings with respect to a general understanding of AF is pointed out

    International criteria for electrocardiographic interpretation in athletes: Consensus statement.

    Get PDF
    Sudden cardiac death (SCD) is the leading cause of mortality in athletes during sport. A variety of mostly hereditary, structural or electrical cardiac disorders are associated with SCD in young athletes, the majority of which can be identified or suggested by abnormalities on a resting 12-lead electrocardiogram (ECG). Whether used for diagnostic or screening purposes, physicians responsible for the cardiovascular care of athletes should be knowledgeable and competent in ECG interpretation in athletes. However, in most countries a shortage of physician expertise limits wider application of the ECG in the care of the athlete. A critical need exists for physician education in modern ECG interpretation that distinguishes normal physiological adaptations in athletes from distinctly abnormal findings suggestive of underlying pathology. Since the original 2010 European Society of Cardiology recommendations for ECG interpretation in athletes, ECG standards have evolved quickly, advanced by a growing body of scientific data and investigations that both examine proposed criteria sets and establish new evidence to guide refinements. On 26-27 February 2015, an international group of experts in sports cardiology, inherited cardiac disease, and sports medicine convened in Seattle, Washington (USA), to update contemporary standards for ECG interpretation in athletes. The objective of the meeting was to define and revise ECG interpretation standards based on new and emerging research and to develop a clear guide to the proper evaluation of ECG abnormalities in athletes. This statement represents an international consensus for ECG interpretation in athletes and provides expert opinion-based recommendations linking specific ECG abnormalities and the secondary evaluation for conditions associated with SCD

    Prediction of postoperative atrial fibrillation using the electrocardiogram: A proof of concept

    Get PDF
    Hospital patients recovering from major cardiac surgery are at high risk of postoperative atrial fibrillation (POAF), an arrhythmia which can be life-threatening. With the development of a tool to predict POAF early enough, the development of the arrhythmia could be potentially prevented using prophylactic treatments, thus reducing risks and hospital costs. To date, no reliable method suitable for autonomous clinical integration has been proposed yet. This thesis presents a study on the prediction of POAF using the electrocardiogram. A novel P-wave quality assessment tool to automatically identify high-quality P-waves was designed, and its clinical utility was assessed. Prediction of paroxysmal atrial fibrillation (AF) was performed by implementing and improving a selection of previously proposed methods. This allowed to perform a systematic comparison of those methods, and to test if their combination improved prediction of AF. Finally, prediction of POAF was tested in a clinically relevant scenario. This included studying the 48 hours preceding POAF, and automatically excluding noise-corrupted P-waves using the quality assessment tool. The P-wave quality assessment tool identified high-quality P-waves with high sensitivity (0.93) and good specificity (0.84). In addition, this tool improved the ability to predict AF, since it improved the precision of P-wave measurements. The best predictors of AF and POAF were measurements of the variability in P-wave time- and morphological features. Paroxysmal AF could be predicted with high specificity (0.93) and good sensitivity (0.82) when several predictors were combined. Furthermore, POAF could be predicted 48 hours before its onset with good sensitivity (0.74) and specificity (0.70). This leaves time for prophylactic treatments to be administered and possibly prevent POAF. Despite being promising, further work is required for these techniques to be useful in the clinical setting

    Quality Control in ECG-based Atrial Fibrillation Screening

    Get PDF
    This thesis comprises an introductory chapter and four papers related to quality control in ECG-based atrial fibrillation (AF) screening. Atrial fibrillation is a cardiac arrhythmia characterized by an irregular rhythm and constitutes a major risk factor for stroke. Anticoagulation therapy significantly reduces this risk, and therefore, AF screening is motivated. Atrial fibrillation screening is often done using ECGs recorded outside the clinical environment. However, the higher susceptibility of such ECGs to noise and artifacts makes the identification of patients with AF challenging. The present thesis addresses these challenges at different levels in the data analysis chain. Paper I presents a convolutional neural network (CNN)-based approach to identify transient noise and artifacts in the detected beat sequence before AF detection. The results show that by inserting a CNN, prior to the AF detector, the number of false AF detections is reduced by 22.5% without any loss in the sensitivity, suggesting that the number of recordings requiring expert review can be significantly reduced. Paper II investigates the signal quality of a novel wet electrode technology, and how the improved signal quality translates to improved beat detection and AF detection performance. The novel electrode technology is designed for reduction of motion artifacts typically present in Holter ECG recordings. The novel electrode technology shows a better signal quality and detection performance when compared to a commercially available counterpart, especially when the subject becomes more active. Thus, it has the potential to reduce the review burden and costs associated with ambulatory monitoring.Paper III introduces a detector for short-episode supraventricular tachycardia (sSVT) in AF screening recordings, which has been shown to be associated with an increased risk for future AF. Therefore, the identification of subjects with suchepisodes may increase the usefulness of AF screening. The proposed detector is based on the assumption that the beats in an sSVT episode display similar morphology, and that episodes including detections of deviating morphology should be excluded. The results show that the number of false sSVT detections can be significantly reduced (by a factor of 6) using the proposed detector.Paper IV introduces a novel ECG simulation tool, which is capable of producing ECGs with various arrhythmia patterns and with several different types of noise and artifacts. Specifically, the ECG simulator includes models to generate noise observed in ambulatory recordings, and when recording using handheld recording devices. The usefulness of the simulator is illustrated in terms of AF detection performance when the CNN training in Paper I is performed using simulated data. The results show a very similar performance when training with simulated data compared to when training with real data. Thus, the proposed simulator is a valuable tool in the development and training of automated ECG processing algorithms. Together, the four parts, in different ways, contribute to improved algorithmic efficiency in AF screening

    Susceptibility to Paroxysmal Atrial Fibrillation: A Study using Sinus Rhythm P Wave Parameters

    Get PDF
    International audienceEarly recognition of patients at high risk for atrial fibrillation may help to minimize potential health risks. The detection of susceptibility to develop atrial fibrillation is thus a real clinical challenge. Whereas many studies have used the signal-averaged P wave, the aim of this work is to determine whether electrocardiographic parameters resulting from the analysis of the P wave in ECG recorded during sinus rhythm could be markers for paroxysmal atrial fibrillation susceptibility. Our idea was to compare the ECG in sinus rhythm from two populations: healthy people and patients subject to paroxysmal atrial fibrillation. In addition to standard P wave parameters (P width, P-R interval,...), the Euclidean distance between beat-to-beat P waves, which has been rarely addressed in this context, was studied on lead V1. Significant differences between the healthy and the paroxysmal atrial fibrillation groups were obtained for various parameters. Moreover, a classification of the two groups based on the joint analysis of P width and P-R interval was suggested. This proposed classification could lead to an effective identification of patients at risk to develop atrial fibrillation

    Characterization of the Substrate Modification in Patients Undergoing Catheter Ablation of Atrial Fibrillation

    Full text link
    Tesis por compendio[ES] La fibrilación auricular (FA) es la arritmia cardíaca más común. A pesar de la gran popularidad de la ablación con catéter (AC) como tratamiento principal, todavía hay margen de mejora. Aunque las venas pulmonares (VPs) son los principales focos de FA, muchos sitios pueden contribuir a su propagación, formando el sustrato de la FA (SFA). El mapeo preciso del SFA y el registro de la modificación del SFA, como marcador positivo después de AC, son fundamentales. Los electrocardiogramas (ECG) y los electrogramas (EGM) se reclutan para este propósito. Los EGM se utilizan para detectar candidatos de AC como áreas que provocan o perpetúan la FA. Por lo tanto, el análisis de EGM es una parte indispensable de AC. Con la capacidad de observar las aurículas globalmente, la principal aplicación de los ECG es evaluar la modificación del SFA analizando las ondas f o P. A pesar del extenso análisis de cualquiera de los tipos de registro, existen algunas brechas. La AC no-VP aumenta el tiempo en quirófano, provocando mayores riesgos y costos. En cuanto al análisis de la modificación del SFA, se utilizan varios umbrales para definir una onda P prolongada. El principal objetivo de la presente Tesis es contribuir al esfuerzo de análisis de SFA y de modificación de SFA. Para ello, la presente Tesis se desarrolló bajo dos hipótesis principales. Que la calidad de la información extraída durante el SFA y el análisis de modificación del SFA se puede mejorar mediante la introducción de pasos innovadores. Además, la combinación de análisis de ECG y EGM puede aumentar la resolución del mapeo y revelar nueva información sobre los mecanismos de FA. Para cumplir con el objetivo principal, el análisis se divide en 4 partes, conformando los 4 capítulos del Compendio de articulos. En primer lugar, se reclutó la dimensión de correlación de grano grueso (DCGG). DCGG localizó de manera confiable EGM complejos y la clasificación por tipos de FA arrojó una precisión del 84 %. Luego, se adoptó un análisis alternativo de la onda P, estudiando por separado su primera y su segunda parte, correspondientes a la aurícula derecha (AD) e izquierda (AI). Los resultados indicaron LA como la principal fuente de modificación del SFA y subrayaron la importancia de estudiar partes integrales de ECG. Los hallazgos de este estudio también sugieren la implementación de partes integrales de ondas P como un posible alivio de las discrepancias en los umbrales de ondas P para definir el tejido fibrótico. Posteriormente, se estudió el efecto diferente del aislamiento de la VP izquierda (AVPI) y derecha (AVPD) sobre la modificación del SFA. AVPI fue la parte crítica, siendo la fuente exclusiva de acortamiento de onda P. El análisis de los registros durante la AC también permitió una observación más cercana de las fluctuaciones de la variabilidad de la frecuencia cardíaca (VFC) a lo largo del procedimiento de CA, lo que reveló información sobre el efecto de la energía de radiofrecuencia (RF) en el tejido auricular. La última parte se centró en el seno coronario (SC), una estructura fundamental en el mapeo de FA para aumentar la resolución de la información. Se definieron los canales más y menos robustos durante el ritmo sinusal (RS) y se investigó la utilidad de SC en la evaluación de la modificación del SFA. Aunque CS no proporcionó una imagen global de la alteración del SFA, pudo registrar con mayor sensibilidad las fluctuaciones en la respuesta auricular durante la AC. Los hallazgos presentados en esta Tesis Doctoral ofrecen una perspectiva alternativa sobre la modificación del SFA y contribuyen al esfuerzo general sobre el mapeo de FA y la evaluación del sustrato posterior a la CAAC, abriendo futuras líneas de investigación hacia una resolución más alta y un mapeo más eficiente de los mecanismos desencadenantes de la FA.[CA] La fibril·lació auricular (FA) és l'arítmia cardíaca més comú. Tot i la gran popularitat de l'ablació amb catèter (AC) com a tractament principal, encara hi ha marge de millora. Tot i que les venes pulmonars (VPs) són els principals focus de FA, molts llocs poden contribuir a la seva propagació, formant el substrat de la FA (SFA). El mapatge precís de l'SFA i el registre de la modificació de l'SFA, com a marcador positiu després d'AC, són fonamentals. Els electrocardiogrames (ECG) i els electrogrames (EGM) es recluten per a aquest propòsit. Els EGM es fan servir per detectar candidats d'AC com a àrees que provoquen o perpetuen la FA. Per tant, lanàlisi dEGM és una part indispensable dAC. Amb la capacitat d'observar les aurícules globalment, la principal aplicació dels ECG és avaluar la modificació de l'SFA analitzant les ones f o P. Tot i l'extensa anàlisi de qualsevol dels tipus de registre, hi ha algunes bretxes. L'AC no-VP augmenta el temps a quiròfan, provocant majors riscos i costos. Pel que fa a l'anàlisi de la modificació de l'SFA, s'utilitzen diversos llindars per definir una ona P perllongada. L'objectiu principal d'aquesta Tesi és contribuir a l'esforç d'anàlisi de SFA i de modificació de SFA. Per això, aquesta Tesi es va desenvolupar sota dues hipòtesis principals. Que la qualitat de la informació extreta durant el SFA i lanàlisi de modificació de lSFA es pot millorar mitjançant la introducció de passos innovadors. A més, la combinació d'anàlisi d'ECG i EGM pot augmentar la resolució del mapatge i revelar informació nova sobre els mecanismes de FA. Per complir amb l'objectiu principal, l'anàlisi es divideix en 4 parts i es conforma els 4 capítols del Compendi d'articles. En primer lloc, es va reclutar la dimensió de correlació de gra gruixut (DCGG). DCGG va localitzar de manera fiable EGM complexos i la classificació per tipus de FA va donar una precisió del 84%. Després, es va adoptar una anàlisi alternativa de l'ona P, estudiant per separat la primera i la segona part corresponents a l'aurícula dreta (AD) i esquerra (AI). Els resultats van indicar LA com la font principal de modificació de l'SFA i van subratllar la importància d'estudiar parts integrals d'ECG. Les troballes d'aquest estudi també suggereixen la implementació de parts integrals d'ones P com a possible alleugeriment de les discrepàncies als llindars d'ones P per definir el teixit fibròtic. Posteriorment, es va estudiar l'efecte diferent de l'aïllament de la VP esquerra (AVPI) i la dreta (AVPD) sobre la modificació de l'SFA. AVPI va ser la part crítica, sent la font exclusiva d'escurçament d'ona P. L'anàlisi dels registres durant l'AC també va permetre una observació més propera de les fluctuacions de la variabilitat de la freqüència cardíaca (VFC) al llarg del procediment de CA , cosa que va revelar informació sobre l'efecte de l'energia de radiofreqüència (RF) en el teixit auricular. L'última part es va centrar al si coronari (SC), una estructura fonamental al mapeig de FA per augmentar la resolució de la informació. Es van definir els canals més i menys robustos durant el ritme sinusal (RS) i es va investigar la utilitat de SC a l'avaluació de la modificació de l'SFA. Tot i que CS no va proporcionar una imatge global de l'alteració de l'SFA, va poder registrar amb més sensibilitat les fluctuacions a la resposta auricular durant l'AC. Les troballes presentades en aquesta Tesi Doctoral ofereixen una perspectiva alternativa sobre la modificació de l'SFA i contribueixen a l'esforç general sobre el mapeig de FA i l'avaluació del substrat posterior a la CAAC, obrint futures línies de recerca cap a una resolució més alta i un mapeig més eficient dels mecanismes desencadenants de la FA.[EN] Atrial fibrillation (AF) is the commonest cardiac arrhythmia. Despite the high popularity of catheter ablation (CA) as the main treatment, there is still room for improvement. Time spent in AF affects the AF confrontation and evolution, with 1,15% of paroxysmal AF patients progressing to persistent annually. Therefore, from diagnosis to follow-up, every aspect that contributes to the AF confrontation is of utmost importance. Although pulmonary veins (PVs) are the main AF foci, many sites may contribute to the AF propagation, by triggering or sustaining the AF, forming the AF substrate. Precise AF substrate mapping and recording of the AF substrate modification, as a positive marker after CA sessions, are critical. Electrocardiograms (ECGs) and electrograms (EGMs) are vastly recruited for this purpose. EGMs are used to detect candidate CA targets as areas that provoke or perpetuate AF. Hence, EGMs analysis is an indispensable part of the CA procedure. With the ability to observe the atria globally, ECGs' main application is to assess the AF substrate modification by analyzing f- or P-waves from recordings before and after CA. Despite the extensive analysis on either recording types, some gaps exist. Non-PV CA increases the time in operation room, provoking higher risks and costs. Furthermore, whether non-PV CA is beneficial is under dispute. As for the AF substrate modification analysis, various thresholds are used to define a prolonged P-wave, related with poor CA prognostics. The main objective of the present Thesis is to contribute to the effort of AF substrate and AF substrate modification analysis. For this purpose, the present Thesis was developed under two main hypotheses. That the information quality extracted during AF substrate and AF substrate modification analysis can be improved by introducing innovative steps. Also, that combining ECG and EGM analysis can augment the mapping resolution and reveal new information regarding AF mechanisms. To accomplish the main objective, the analysis is split in 4 parts, forming the 4 chapters of the Compendium of publications. Firstly, coarse-grained correlation dimension (CGCD) was recruited. CGCD reliably localized highly complex EGMs and classification by AF types yielded 84% accuracy. Then, an alternative P-wave analysis was suggested, studying separately the first and second P-wave parts, corresponding to the right (RA) and left (LA) atrium. The findings indicated LA as the main AF substrate modification source and underlined the importance of studying integral ECG parts. The findings of this study additionally suggest the implementation of integral P-wave parts as a possible alleviation for the discrepancies in P-wave thresholds to define fibrotic tissue. Afterwards, the different effect of left (LPVI) and right pulmonary vein isolation (RPVI) on the AF substrate modification was studied. LPVI was the critical part, being the exclusive source of P-wave shortening. Analysis of recordings during CA also allowed a closer observation of the heart rate variability (HRV) fluctuations throughout the CA procedure, revealing information on the effect of radiofrequency (RF) energy on the atrial tissue. The last part was focused on coronary sinus (CS), a fundamental structure in AF mapping to increase the information resolution. The most and least robust channels during sinus rhythm (SR) were defined and the utility of CS in AF substrate modification evaluation was investigated. Although CS did not provide a global picture of the AF substrate alteration, it was able to record with higher sensitivity the fluctuations in the atrial response during the application of RF energy. The findings presented in this Doctoral Thesis offer an alternative perspective on the AF substrate modification and contribute to the overall effort on AF mapping and post-CA substrate evaluation, opening future lines of research towards a higher resolution and more efficient mapping of the AF drivers.Vraka, A. (2022). Characterization of the Substrate Modification in Patients Undergoing Catheter Ablation of Atrial Fibrillation [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/191410Compendi
    corecore