10,990 research outputs found

    Evaluation of home-based rehabilitation sensing systems with respect to standardised clinical tests

    Get PDF
    With increased demand for tele-rehabilitation, many autonomous home-based rehabilitation systems have appeared recently. Many of these systems, however, suffer from lack of patient acceptance and engagement or fail to provide satisfactory accuracy; both are needed for appropriate diagnostics. This paper first provides a detailed discussion of current sensor-based home-based rehabilitation systems with respect to four recently established criteria for wide acceptance and long engagement. A methodological procedure is then proposed for the evaluation of accuracy of portable sensing home-based rehabilitation systems, in line with medically-approved tests and recommendations. For experiments, we deploy an in-house low-cost sensing system meeting the four criteria of acceptance to demonstrate the effectiveness of the proposed evaluation methodology. We observe that the deployed sensor system has limitations in sensing fast movement. Indicators of enhanced motivation and engagement are recorded through the questionnaire responses with more than 83% of the respondents supporting the system’s motivation and engagement enhancement. The evaluation results demonstrate that the deployed system is fit for purpose with statistically significant ( ϱc>0.99 , R2>0.94 , ICC>0.96 ) and unbiased correlation to the golden standard

    Free-living monitoring of Parkinson’s disease: lessons from the field

    Get PDF
    Wearable technology comprises miniaturized sensors (e.g. accelerometers) worn on the body and/or paired with mobile devices (e.g. smart phones) allowing continuous patient monitoring in unsupervised, habitual environments (termed free-living). Wearable technologies are revolutionising approaches to healthcare due to their utility, accessibility and affordability. They are positioned to transform Parkinson’s disease (PD) management through provision of individualised, comprehensive, and representative data. This is particularly relevant in PD where symptoms are often triggered by task and free-living environmental challenges that cannot be replicated with sufficient veracity elsewhere. This review concerns use of wearable technology in free-living environments for people with PD. It outlines the potential advantages of wearable technologies and evidence for these to accurately detect and measure clinically relevant features including motor symptoms, falls risk, freezing of gait, gait, functional mobility and physical activity. Technological limitations and challenges are highlighted and advances concerning broader aspects are discussed. Recommendations to overcome key challenges are made. To date there is no fully validated system to monitor clinical features or activities in free living environments. Robust accuracy and validity metrics for some features have been reported, and wearable technology may be used in these cases with a degree of confidence. Utility and acceptability appears reasonable, although testing has largely been informal. Key recommendations include adopting a multi-disciplinary approach for standardising definitions, protocols and outcomes. Robust validation of developed algorithms and sensor-based metrics is required along with testing of utility. These advances are required before widespread clinical adoption of wearable technology can be realise

    Automating the timed up and go test using a depth camera

    Get PDF
    Fall prevention is a human, economic and social issue. The Timed Up and Go (TUG) test is widely used to identify individuals with a high fall risk. However, this test has been criticized because its “diagnostic” is too dependent on the conditions in which it is performed and on the healthcare professionals running it. We used the Microsoft Kinect ambient sensor to automate this test in order to reduce the subjectivity of outcome measures and to provide additional information about patient performance. Each phase of the TUG test was automatically identified from the depth images of the Kinect. Our algorithms accurately measured and assessed the elements usually measured by healthcare professionals. Specifically, average TUG test durations provided by our system differed by only 0.001 s from those measured by clinicians. In addition, our system automatically extracted several additional parameters that allowed us to accurately discriminate low and high fall risk individuals. These additional parameters notably related to the gait and turn pattern, the sitting position and the duration of each phase. Coupling our algorithms to the Kinect ambient sensor can therefore reliably be used to automate the TUG test and perform a more objective, robust and detailed assessment of fall risk

    Gait characterization using wearable inertial sensors in healthy and pathological populations

    Get PDF
    Gait analysis is emerging as an effective tool to detect an incipient neurodegenerative disease or to monitor its progression. It has been shown that gait disturbances are an early indicator for cognitive impairments and can predict progression to neurodegenerative diseases. Furthermore, gait performance is a predictor of fall status, morbidity and mortality. Instrumented gait analysis provides quantitative measures to support the investigation of gait pathologies and the definition of targeted rehabilitation programs. In this framework, technologies such as inertial sensors are well accepted, and increasingly employed, as tools to characterize locomotion patterns and their variability in research settings. The general aim of this thesis is the evaluation, comparison and refinement of methods for gait characterization using magneto-inertial measurement units (MIMUs), in order to contribute to the migration of instrumented gait analysis from state of the art to state of the science (i.e.: from research towards its application in standard clinical practice). At first, methods for the estimation of spatio-temporal parameters during straight gait were investigated. Such parameters are in fact generally recognized as key metrics for an objective evaluation of gait and a quantitative assessment of clinical outcomes. Although several methods for their estimate have been proposed, few provided a thorough validation. Therefore an error analysis across different pathologies, multiple clinical centers and large sample size was conducted to further validate a previously presented method (TEADRIP). Results confirmed the applicability and robustness of the TEADRIP method. The combination of good performance, reliability and range of usage indicate that the TEADRIP method can be effectively adopted for gait spatio-temporal parameter estimation in the routine clinical practice. However, while traditionally gait analysis is applied to straight walking, several clinical motor tests include turns between straight gait segments. Furthermore, turning is used to evaluate subjects’ motor ability in more challenging circumstances. The second part of the research therefore headed towards the application of gait analysis on turning, both to segment it (i.e.: distinguish turns and straight walking bouts) and to specifically characterize it. Methods for turn identification based on a single MIMU attached to the trunk were implemented and their performance across pathological populations was evaluated. Focusing on Parkinson’s Disease (PD) subjects, turn characterization was also addressed in terms of onset and duration, using MIMUs positioned both on the trunk and on the ankles. Results showed that in PD population turn characterization with the sensors at the ankles lacks of precision, but that a single MIMU positioned on the low back is functional for turn identification. The development and validation of the methods considered in these works allowed for their application to clinical studies, in particular supporting the spatio-temporal parameters analysis in a PD treatment assessment and the investigation of turning characteristic in PD subjects with Freezing of Gait. In the first application, comparing the pre and post parameters it was possible to objectively determine the effectiveness of a rehabilitation treatment. In the second application, quantitative measures confirmed that in PD subjects with Freezing of Gait turning 360° in place is further compromised (and requires additional cognitive effort) compared to turning 180° while walking

    Long-term unsupervised mobility assessment in movement disorders

    Get PDF
    Mobile health technologies (wearable, portable, body-fixed sensors, or domestic-integrated devices) that quantify mobility in unsupervised, daily living environments are emerging as complementary clinical assessments. Data collected in these ecologically valid, patient-relevant settings can overcome limitations of conventional clinical assessments, as they capture fluctuating and rare events. These data could support clinical decision making and could also serve as outcomes in clinical trials. However, studies that directly compared assessments made in unsupervised and supervised (eg, in the laboratory or hospital) settings point to large disparities, even in the same parameters of mobility. These differences appear to be affected by psychological, physiological, cognitive, environmental, and technical factors, and by the types of mobilities and diagnoses assessed. To facilitate the successful adaptation of the unsupervised assessment of mobility into clinical practice and clinical trials, clinicians and researchers should consider these disparities and the multiple factors that contribute to them

    Will We Do If We Can? Habitual Qualitative and Quantitative Physical Activity in Multi-Morbid, Older Persons with Cognitive Impairment

    Get PDF
    This study aimed to identify determinants of quantitative dimensions of physical activity (PA; duration, frequency, and intensity) in community-dwelling, multi-morbid, older persons with cognitive impairment (CI). In addition, qualitative and quantitative aspects of habitual PA have been described. Quantitative PA and qualitative gait characteristics while walking straight and while walking turns were documented by a validated, sensor-based activity monitor. Univariate and multiple linear regression analyses were performed to delineate associations of quantitative PA dimensions with qualitative characteristics of gait performance and further potential influencing factors (motor capacity measures, demographic, and health-related parameters). In 94 multi-morbid, older adults (82.3 ± 5.9 years) with CI (Mini-Mental State Examination score: 23.3 ± 2.4), analyses of quantitative and qualitative PA documented highly inactive behavior (89.6% inactivity) and a high incidence of gait deficits, respectively. The multiple regression models (adjusted R2^{2} = 0.395–0.679, all p < 0.001) identified specific qualitative gait characteristics as independent determinants for all quantitative PA dimensions, whereas motor capacity was an independent determinant only for the PA dimension duration. Demographic and health-related parameters were not identified as independent determinants. High associations between innovative, qualitative, and established, quantitative PA performances may suggest gait quality as a potential target to increase quantity of PA in multi-morbid, older persons

    Wearable Sensors Applied in Movement Analysis

    Get PDF
    Recent advances in electronics have led to sensors whose sizes and weights are such that they can be placed on living systems without impairing their natural motion and habits. They may be worn on the body as accessories or as part of the clothing and enable personalized mobile information processing. Wearable sensors open the way for a nonintrusive and continuous monitoring of body orientation, movements, and various physiological parameters during motor activities in real-life settings. Thus, they may become crucial tools not only for researchers, but also for clinicians, as they have the potential to improve diagnosis, better monitor disease development and thereby individualize treatment. Wearable sensors should obviously go unnoticed for the people wearing them and be intuitive in their installation. They should come with wireless connectivity and low-power consumption. Moreover, the electronics system should be self-calibrating and deliver correct information that is easy to interpret. Cross-platform interfaces that provide secure data storage and easy data analysis and visualization are needed.This book contains a selection of research papers presenting new results addressing the above challenges

    Quantitative Gait and Balance Outcomes for Ataxia Trials: Consensus Recommendations by the Ataxia Global Initiative Working Group on Digital-Motor Biomarkers

    Get PDF
    With disease-modifying drugs on the horizon for degenerative ataxias, ecologically valid, finely granulated, digital health measures are highly warranted to augment clinical and patient-reported outcome measures. Gait and balance disturbances most often present as the first signs of degenerative cerebellar ataxia and are the most reported disabling features in disease progression. Thus, digital gait and balance measures constitute promising and relevant performance outcomes for clinical trials. This narrative review with embedded consensus will describe evidence for the sensitivity of digital gait and balance measures for evaluating ataxia severity and progression, propose a consensus protocol for establishing gait and balance metrics in natural history studies and clinical trials, and discuss relevant issues for their use as performance outcomes

    3D Gait Abnormality Detection Employing Contactless IR-UWB Sensing Phenomenon

    Get PDF
    Gait disorder diagnosis and rehabilitation is one area where human perception and observation are highly integrated. Predominantly, gait evaluation, comprises technological devices for gait analysis such as, dedicated force sensors, cameras, and wearable sensor based solutions, however they are limited by insufficient gait parameter recognition, post processing, installation costs, mobility, and skin irritation issues. Thus, the proposed study concentrates on the creation of a widely deployable, noncontact and non-intrusive gait recognition method from impulse radio ultra wideband (IR-UWB) sensing phenomenon, where a standalone IR-UWB system can detect gait problems with less human intervention. A 3D human motion model for gait identification from IR-UWB has been proposed with embracing spherical trigonometry and vector algebra to determine knee angles. Subsequently, normal and abnormal walking subjects were involved in this study. Abnormal gait subjects belong to the spastic gait category only. The prototype has been tested in both the anechoic and multipath environments. The outcomes have been corroborated with a simultaneously deployed Kinect Xbox sensor and supported by statistical graphical approach Bland and Altman (B&A) analysis
    • 

    corecore