6,969 research outputs found
R&D Paths of Pixel Detectors for Vertex Tracking and Radiation Imaging
This report reviews current trends in the R&D of semiconductor pixellated
sensors for vertex tracking and radiation imaging. It identifies requirements
of future HEP experiments at colliders, needed technological breakthroughs and
highlights the relation to radiation detection and imaging applications in
other fields of science.Comment: 17 pages, 2 figures, submitted to the European Strategy Preparatory
Grou
A new CMS pixel detector for the LHC luminosity upgrade
The CMS inner pixel detector system is planned to be replaced during the
first phase of the LHC luminosity upgrade. The plans foresee an ultra low mass
system with four barrel layers and three disks on either end. With the expected
increase in particle rates, the electronic readout chain will be changed for
fast digital signals. An overview of the envisaged design options for the
upgraded CMS pixel detector is given, as well as estimates of the tracking and
vertexing performance.Comment: 5 pages, 8 figures, proceedings of 8th International Conference on
Radiation Effects on Semiconductor Materials Detectors and Device
The next detectors for gravitational wave astronomy
This paper focuses on the next detectors for gravitational wave astronomy
which will be required after the current ground based detectors have completed
their initial observations, and probably achieved the first direct detection of
gravitational waves. The next detectors will need to have greater sensitivity,
while also enabling the world array of detectors to have improved angular
resolution to allow localisation of signal sources. Sect. 1 of this paper
begins by reviewing proposals for the next ground based detectors, and presents
an analysis of the sensitivity of an 8 km armlength detector, which is proposed
as a safe and cost-effective means to attain a 4-fold improvement in
sensitivity. The scientific benefits of creating a pair of such detectors in
China and Australia is emphasised. Sect. 2 of this paper discusses the high
performance suspension systems for test masses that will be an essential
component for future detectors, while sect. 3 discusses solutions to the
problem of Newtonian noise which arise from fluctuations in gravity gradient
forces acting on test masses. Such gravitational perturbations cannot be
shielded, and set limits to low frequency sensitivity unless measured and
suppressed. Sects. 4 and 5 address critical operational technologies that will
be ongoing issues in future detectors. Sect. 4 addresses the design of thermal
compensation systems needed in all high optical power interferometers operating
at room temperature. Parametric instability control is addressed in sect. 5.
Only recently proven to occur in Advanced LIGO, parametric instability
phenomenon brings both risks and opportunities for future detectors. The path
to future enhancements of detectors will come from quantum measurement
technologies. Sect. 6 focuses on the use of optomechanical devices for
obtaining enhanced sensitivity, while sect. 7 reviews a range of quantum
measurement options
Belle II Technical Design Report
The Belle detector at the KEKB electron-positron collider has collected
almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an
upgrade of KEKB is under construction, to increase the luminosity by two orders
of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2
/s luminosity. To exploit the increased luminosity, an upgrade of the Belle
detector has been proposed. A new international collaboration Belle-II, is
being formed. The Technical Design Report presents physics motivation, basic
methods of the accelerator upgrade, as well as key improvements of the
detector.Comment: Edited by: Z. Dole\v{z}al and S. Un
A review of advances in pixel detectors for experiments with high rate and radiation
The Large Hadron Collider (LHC) experiments ATLAS and CMS have established
hybrid pixel detectors as the instrument of choice for particle tracking and
vertexing in high rate and radiation environments, as they operate close to the
LHC interaction points. With the High Luminosity-LHC upgrade now in sight, for
which the tracking detectors will be completely replaced, new generations of
pixel detectors are being devised. They have to address enormous challenges in
terms of data throughput and radiation levels, ionizing and non-ionizing, that
harm the sensing and readout parts of pixel detectors alike. Advances in
microelectronics and microprocessing technologies now enable large scale
detector designs with unprecedented performance in measurement precision (space
and time), radiation hard sensors and readout chips, hybridization techniques,
lightweight supports, and fully monolithic approaches to meet these challenges.
This paper reviews the world-wide effort on these developments.Comment: 84 pages with 46 figures. Review article.For submission to Rep. Prog.
Phy
- …