530 research outputs found

    Non-invasive wearable sensing system for sleep disorder monitoring

    Get PDF
    Dissertação de mestrado, Engenharia Electrónica e Telecomunicações, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2017This Master Thesis introduced a proposal of a remote sensory system for the detection of sleep disorders in geriatric outpatients. Although the most accurate solution would be an in-depth study in a sleep clinic, it is not a realistic environment for the elderly. The objective is that the patient stays at home, and without changing their daily routines, the clinicians get objective information in order to make a correct diagnosis of the sleep disorders. Sleep disorders are often classified as medical disorders corresponding to modifications on the sleep patterns and the amount of these modifications increase with age. However, regularly, these illnesses are undiagnosed, since is hard for the patients to explain the symptoms to the doctor. To achieve the proposed objective, we studied the polysomnography bio-signals that could be used to accurate reflect the sleep disorders occurrences. We designed a Body Sensor Network (BSN) to be divided into both movement assessment (Accelerometer and Gyroscope) and biomedical signals (EMG, ECG, PPG, GSR) evaluation. These signals, reflecting both breathing and cardiac activities, are processed by a specifically developed algorithm. The reduction of the number of sensors was also envisaged, and it was decided to use 3 biomedical sensors instead of the minimum of 22 sensors used by polysomnography. Thus, to offer better visualization of the recorded signals a software interface was developed to include the processing and visualization of the signals. To identify the sleep stage and apnea state, we settled an algorithm that processes both ECG and EMG. To validate this algorithm, it was decided to use two sources of data: PhysioNet data base containing ECG and EMG signals and data recorded by our BSN on volunteers. With this work, we were able to build a BSN capable of detecting a set of sleep disorders, without using any invasive method. The network provides reliable data, and using the developed interface, it helps elderly health providers to carry out an in-depth analysis of the information and to better identify sleep disorders.Este trabalho introduz uma proposta de uma monitorização remota de saúde para a deteção de desordens de sono em pacientes ambulatórios geriátricos. As desordens de sono são as condições que afetam a habilidade de dormir bem regularmente. Podem ser causadas por um problema de saúde ou por elevado stress. Embora a solução mais precisa seja um estudo aprofundado numa clínica de sono, este não corresponde a um cenário realista para os idosos, corrompendo os dados registados devido ao stress associado ao ambiente desconhecido. De modo a que o paciente não saia de sua casa e não altere as suas rotinas diárias, o sistema desenvolvido tem um uso simples que pode ser utilizado num ambiente amigável e seguro para o paciente. Isto irá providenciar informação objetiva aos clínicos, de modo a diagnosticar as desordens de sono de maneira correta, já que os pacientes por vezes têm dificuldade em explicar os sintomas aos médicos durante a consulta, o que vai provocar um elevado número de casos subdiagnosticados. O primeiro passo a tomar, de modo a criar um sistema de monitoramento remoto doméstico, é definir quais são os sinais a monitorizar. O primeiro sinal definido para ser alvo de monitoramento foi o Eletrocardiograma (ECG). A razão deve-se ao fato de este sinal já ter sido empregado em variadíssimos estudos relativos ao sono, em que os pesquisadores utilizam a Heart Rate Variability (HRV) para a deteção de apneias de sono (tanto no domínio do tempo ou frequência) e outros transtornos de sono. Neste trabalho vamos tentar identificar episódios de acoplamento cardiorrespiratório, ao analisar a HRV. O segundo sinal a ser eleito foi o Eletromiograma (EMG) proveniente do queixo. Este sinal foi escolhido, devido à correlação que tinha com o sinal ECG na presença de episódios de apneia obstrutivos. Este fenómeno deve-se à dificuldade que o paciente tem ao inspirar, pois como tem as vias respiratórias obstruídas, o ar não chega aos pulmões. Isto vai levar a um esforço extra por parte do paciente, que se vai traduzir num aumento de amplitude do sinal. Esta variação vai novamente aparecer dez ou mais segundos depois, quando o ar voltar a entrar nos pulmões, e o paciente voltar a respirar normalmente. Para além de estes dois sinais biomédicos, também vamos monitorizar o sinal Fotopletismografia (PPG) e a resposta galvânica da pele (GSR). O PPG é usado para detetar as diferenças no volume do sangue, de modo a avaliar a circulação periférica enquanto que a resposta galvânica mede a condutividade da pele. Ambos os sinais apresentaram características distintivas na presença de apneia, e podem ser alvo de estudo detalhado em trabalhos futuros. Em termos de sinal de movimento, foram gravados e analisados os sinais do acelerómetros e giroscópios em dois locais distintos: na região do diafragma, de modo a obter dados que se possam correlacionar com doenças respiratórias relacionadas com o sono, e na coxa esquerda. Esta informação não vai ser utilizada minuciosamente no presente trabalho, mas no futuro irá ser empregada de modo a ser correlacionada com distúrbios do movimento do sono. Identificados os sinais a ser supervisionados e a informação proveniente, vai ser desenvolvido um algoritmo para diferenciar o estado de apneia obstrutiva (OSA) e o estado de sono normal (NS). No algoritmo proposto foi processado o sinal ECG de modo a obter a HRV. O nosso algoritmo foi baseado no domínio da frequência, dado que a literatura aponta como a forma mais adequada para revelar diferenças de episódios de apneia obstrutiva e sono normal [1]. Ao processar a HRV, obtemos as suas características, e é efetuada a densidade espetral de potência (PSD) na Very Low Frequency (VLF) e High Frequency (HF). Escolhemos estas duas bandas de frequência, porque está provado que são as melhores na distinção entre o estado de sono e o estado de apneia. No caso da VLF, o máximo em OSA é mais proeminente que no NS. Já o inverso ocorre na banda de HF, em que no estado NS, existe um pico que surge devido à arritmia do seio respiratório (RSA) e que normalmente tem o aspeto de uma curva gaussiana. Reconhecidas as diferenças entre os dois estados, são definidos thresholds para estado de apneia e estado de sono normal. Estes limites serão verificado por uma Moving Average Window com um tamanho de 60 segundos. No começo, o algoritmo vai desprezar os primeiro 60 segundos. Após este período, a janela média móvel vai fazer a PSD para HF e VLF e verifica se para ambos os resultados, o threshold é cumprido. Caso os limites sejam atingidos, a janela desloca-se 10 segundos, e aplica os mesmo método, durante os próximos 50 segundos, de modo a termos os valores para 60 segundos. Após a recolha total de dados, é feita a média dos 60 segundos para as duas bandas de frequência. Se ambas atingirem o threshold definido, o intervalo é definido como OSA. Para testar este algoritmo foram utilizadas duas bases de dados: a PhysioNet, que tem informação clinicamente anotada por médicos e é utilizada em diversos trabalhos nesta área, e também iremos testar na informação recolhida pela nossa rede de sensores. Relativamente à base de dados da PhysioNet, os resultados obtidos foram bastante satisfatórios, com precisão a 87,8%, especificidade a 89,9% e sensibilidade a 86,3%. No caso dos sinais recolhidos pela rede de sensores proposta, foi escolhido um dos voluntários que já tinha sido previamente diagnósticos com apneia severa de modo a aumentar as nossas chances de encontrar episódios de apneia. Não foi possível definir valores para a precisão, especificidade e sensibilidade já que não temos um sinal de referência com anotações médicas, para compararmos com os resultados obtidos pelo nosso algoritmo. Em alguns intervalos que foram identificados como episódios de apneia, os sinais recolhidos foram verificados no domínio do tempo, e foram encontradas correlações entre o sinal HRV, EMG, acelerómetro e giroscópio, em que estes dois últimos são sinais obtidos oriundos do peito. De modo a aumentar a precisão do sistema proposto, o próximo passo vai ser incluir o sinal EMG no nosso sistema. Como foi observado em literatura previamente lida, é possível usar a PSD no sinal EMG, para diferenciar entre indivíduos com determinada patologia e indivíduos saudáveis [2]. Por isso aplicamos a PSD no sinal EMG, nos dois diferentes estados (NS e OSA) e obtivemos curvas semelhantes para ambos os estados, obtidas no sinal ECG. Tal fato deve-se provavelmente à componente respiratória que vai influenciar o sinal muscular obtido do queixo. De modo a que os sinais sejam facilmente visualizados, também foi desenvolvida uma interface gráfica, na aplicação do Matlab™ GUIDE, que irá dar aos utilizadores acesso aos sinais gravados pela nossa rede de sensores, e possivelmente a aplicação do algoritmo proposto, para vermos em que pontos os episódios de apneia ocorreram

    Upper airways segmentation using principal curvatures

    Get PDF
    Esta tesis propone una nueva técnica para segmentar las vías aéreas superiores. Esta propuesta permite la extracción de estructuras curvilíneas usando curvaturas principales. La propuesta permite la extracción de éstas estructuras en imágenes 2D y 3D. Entre las principales novedades se encuentra la propuesta de un nuevo criterio de parada en la propagación del algoritmo de realce de contraste (operador multi-escala de tipo sombrero alto). De la misma forma, el criterio de parada propuesto es usado para detener los algoritmos de difusión anisotrópica. Además, un nuevo criterio es propuesto para seleccionar las curvaturas principales que conforman las estructuras curvilíneas, que se basa en los criterios propuestos por Steger, Deng et. al. y Armande et. al. Además, se propone un nuevo algoritmo para realizar la supresión de nomáximos que permite reducir la presencia de discontinuidades en el borde de las estructuras curvilíneas. Para extraer los bordes de las estructuras curvilíneas, se utiliza un algoritmo de enlace que incluye un nuevo criterio de distancia para reducir la aparición de agujeros en la estructura final. Finalmente, con base en los resultados obtenidos, se utiliza un algoritmo morfológico para cerrar los agujeros y se aplica un algoritmo de crecimiento de regiones para obtener la segmentación final de las vías respiratorias superiores.This dissertation proposes a new approach to segment the upper airways. This proposal allows the extraction of curvilinear structures based on the principal curvatures. The proposal allows extracting these structures from 2D and 3D images. Among the main novelties is the proposal of a new stopping criterion to stop the propagation of the contrast enhancement algorithm (multiscale top-hat morphological operator). In the same way, the proposed stopping criterion is used to stop the anisotropic diffusion algorithms. In addition, a new criterion is proposed to select the principal curvatures that make up the curvilinear structures, which is based on the criteria proposed by Steger, Deng et. al. and Armande et. al. Furthermore, a new algorithm to perform the non-maximum suppression that allows reducing the presence of discontinuities in the border of curvilinear structures is proposed. To extract the edges of the curvilinear structures, a linking algorithm is used that includes a new distance criterion to reduce the appearance of gaps in the final structure. Finally, based on the obtained results, a morphological algorithm is used to close the gaps and a region growing algorithm to obtain the final upper airways segmentation is applied.Doctor en IngenieríaDoctorad

    A Textbook of Advanced Oral and Maxillofacial Surgery

    Get PDF
    The scope of OMF surgery has expanded; encompassing treatment of diseases, disorders, defects and injuries of the head, face, jaws and oral cavity. This internationally-recognized specialty is evolving with advancements in technology and instrumentation. Specialists of this discipline treat patients with impacted teeth, facial pain, misaligned jaws, facial trauma, oral cancer, cysts and tumors; they also perform facial cosmetic surgery and place dental implants. The contents of this volume essentially complements the volume 1; with chapters that cover both basic and advanced concepts on complex topics in oral and maxillofacial surgery

    Analog and Mixed Signal Design towards a Miniaturized Sleep Apnea Monitoring Device

    Get PDF
    Sleep apnea is a sleep-induced breathing disorder with symptoms of momentary and often repetitive cessations in breathing rhythm or sustained reductions in breathing amplitude. The phenomenon is known to occur with varying degrees of severity in literally millions of people around the world and cause a range of chronicle health issues. In spite of its high prevalence and serious consequences, nearly 80% of people with sleep apnea condition remain undiagnosed. The current standard diagnosis technique, termed polysomnography or PSG, requires the patient to schedule and undergo a complex full-night sleep study in a specially-equipped sleep lab. Due to both high cost and substantial inconvenience, millions of apnea patients are still undiagnosed and thus untreated. This research work aims at a simple, reliable, and miniaturized solution for in-home sleep apnea diagnosis purposes. The proposed solution bears high-level integration and minimal interference with sleeping patients, allowing them to monitor their apnea conditions at the comfort of their homes. Based on a MEMS sensor and an effective apnea detection algorithm, a low-cost single-channel apnea screening solution is proposed. A custom designed IC chip implements the apnea detection algorithm using time-domain signal processing techniques. The chip performs autonomous apnea detection and scoring based on the patient’s airflow signals detected by the MEMS sensor. Variable sensitivity is enabled to accommodate different breathing signal amplitudes. The IC chip was fabricated in standard 0.5-μm CMOS technology. A prototype device was designed and assembled including a MEMS sensor, the apnea detection IC chip, a PSoC platform, and wireless transceiver for data transmission. The prototype device demonstrates a valuable screening solution with great potential to reach the broader public with undiagnosed apnea conditions. In a battery-operated miniaturized medical device, an energy-efficient analog-to-digital converter is an integral part linking the analog world of biomedical signals and the digital domain with powerful signal processing capabilities. This dissertation includes the detailed design of a successive approximation register (SAR) ADC for ultra-low power applications. The ADC adopts an asynchronous 2b/step scheme that halves both conversion time and DAC/digital circuit’s switching activities to reduce static and dynamic energy consumption. A low-power sleep mode is engaged at the end of all conversion steps during each clock period. The technical contributions of this ADC design include an innovative 2b/step reference scheme based on a hybrid R-2R/C-3C DAC, an interpolation-assisted time-domain 2b comparison scheme, and a TDC with dual-edge-comparison mechanism. The prototype ADC was fabricated in 0.18μm CMOS process with an active area of 0.103 mm^(2), and achieves an ENoB of 9.2 bits and an FoM of 6.7 fJ/conversion-step at 100-kS/s

    Models and Analysis of Vocal Emissions for Biomedical Applications

    Get PDF
    The MAVEBA Workshop proceedings, held on a biannual basis, collect the scientific papers presented both as oral and poster contributions, during the conference. The main subjects are: development of theoretical and mechanical models as an aid to the study of main phonatory dysfunctions, as well as the biomedical engineering methods for the analysis of voice signals and images, as a support to clinical diagnosis and classification of vocal pathologies

    Methods and application areas of endoscopic optical coherence tomography

    Get PDF
    We review the current state of research in endoscopic optical coherence tomography (OCT). We first survey the range of available endoscopic optical imaging techniques. We then discuss the various OCT-based endoscopic methods that have thus far been developed. We compare the different endoscopic OCT methods in terms of their scan performance. Next, we examine the application range of endoscopic OCT methods. In particular, we look at the reported utility of the methods in digestive, intravascular, respiratory, urinary and reproductive systems. We highlight two additional applications—biopsy procedures and neurosurgery—where sufficiently compact OCT-based endoscopes can have significant clinical impacts

    Aerospace medicine and biology: A continuing bibliography with indexes, supplement 129, June 1974

    Get PDF
    This special bibliography lists 280 reports, articles, and other documents introduced into the NASA scientific and technical information system in May 1974

    Earables: Wearable Computing on the Ears

    Get PDF
    Kopfhörer haben sich bei Verbrauchern durchgesetzt, da sie private Audiokanäle anbieten, zum Beispiel zum Hören von Musik, zum Anschauen der neuesten Filme während dem Pendeln oder zum freihändigen Telefonieren. Dank diesem eindeutigen primären Einsatzzweck haben sich Kopfhörer im Vergleich zu anderen Wearables, wie zum Beispiel Smartglasses, bereits stärker durchgesetzt. In den letzten Jahren hat sich eine neue Klasse von Wearables herausgebildet, die als "Earables" bezeichnet werden. Diese Geräte sind so konzipiert, dass sie in oder um die Ohren getragen werden können. Sie enthalten verschiedene Sensoren, um die Funktionalität von Kopfhörern zu erweitern. Die räumliche Nähe von Earables zu wichtigen anatomischen Strukturen des menschlichen Körpers bietet eine ausgezeichnete Plattform für die Erfassung einer Vielzahl von Eigenschaften, Prozessen und Aktivitäten. Auch wenn im Bereich der Earables-Forschung bereits einige Fortschritte erzielt wurden, wird deren Potenzial aktuell nicht vollständig abgeschöpft. Ziel dieser Dissertation ist es daher, neue Einblicke in die Möglichkeiten von Earables zu geben, indem fortschrittliche Sensorikansätze erforscht werden, welche die Erkennung von bisher unzugänglichen Phänomenen ermöglichen. Durch die Einführung von neuartiger Hardware und Algorithmik zielt diese Dissertation darauf ab, die Grenzen des Erreichbaren im Bereich Earables zu verschieben und diese letztlich als vielseitige Sensorplattform zur Erweiterung menschlicher Fähigkeiten zu etablieren. Um eine fundierte Grundlage für die Dissertation zu schaffen, synthetisiert die vorliegende Arbeit den Stand der Technik im Bereich der ohr-basierten Sensorik und stellt eine einzigartig umfassende Taxonomie auf der Basis von 271 relevanten Publikationen vor. Durch die Verbindung von Low-Level-Sensor-Prinzipien mit Higher-Level-Phänomenen werden in der Dissertation anschließ-end Arbeiten aus verschiedenen Bereichen zusammengefasst, darunter (i) physiologische Überwachung und Gesundheit, (ii) Bewegung und Aktivität, (iii) Interaktion und (iv) Authentifizierung und Identifizierung. Diese Dissertation baut auf der bestehenden Forschung im Bereich der physiologischen Überwachung und Gesundheit mit Hilfe von Earables auf und stellt fortschrittliche Algorithmen, statistische Auswertungen und empirische Studien vor, um die Machbarkeit der Messung der Atemfrequenz und der Erkennung von Episoden erhöhter Hustenfrequenz durch den Einsatz von In-Ear-Beschleunigungsmessern und Gyroskopen zu demonstrieren. Diese neuartigen Sensorfunktionen unterstreichen das Potenzial von Earables, einen gesünderen Lebensstil zu fördern und eine proaktive Gesundheitsversorgung zu ermöglichen. Darüber hinaus wird in dieser Dissertation ein innovativer Eye-Tracking-Ansatz namens "earEOG" vorgestellt, welcher Aktivitätserkennung erleichtern soll. Durch die systematische Auswertung von Elektrodenpotentialen, die um die Ohren herum mittels eines modifizierten Kopfhörers gemessen werden, eröffnet diese Dissertation einen neuen Weg zur Messung der Blickrichtung. Dabei ist das Verfahren weniger aufdringlich und komfortabler als bisherige Ansätze. Darüber hinaus wird ein Regressionsmodell eingeführt, um absolute Änderungen des Blickwinkels auf der Grundlage von earEOG vorherzusagen. Diese Entwicklung eröffnet neue Möglichkeiten für Forschung, welche sich nahtlos in das tägliche Leben integrieren lässt und tiefere Einblicke in das menschliche Verhalten ermöglicht. Weiterhin zeigt diese Arbeit, wie sich die einzigarte Bauform von Earables mit Sensorik kombinieren lässt, um neuartige Phänomene zu erkennen. Um die Interaktionsmöglichkeiten von Earables zu verbessern, wird in dieser Dissertation eine diskrete Eingabetechnik namens "EarRumble" vorgestellt, die auf der freiwilligen Kontrolle des Tensor Tympani Muskels im Mittelohr beruht. Die Dissertation bietet Einblicke in die Verbreitung, die Benutzerfreundlichkeit und den Komfort von EarRumble, zusammen mit praktischen Anwendungen in zwei realen Szenarien. Der EarRumble-Ansatz erweitert das Ohr von einem rein rezeptiven Organ zu einem Organ, das nicht nur Signale empfangen, sondern auch Ausgangssignale erzeugen kann. Im Wesentlichen wird das Ohr als zusätzliches interaktives Medium eingesetzt, welches eine freihändige und augenfreie Kommunikation zwischen Mensch und Maschine ermöglicht. EarRumble stellt eine Interaktionstechnik vor, die von den Nutzern als "magisch und fast telepathisch" beschrieben wird, und zeigt ein erhebliches ungenutztes Potenzial im Bereich der Earables auf. Aufbauend auf den vorhergehenden Ergebnissen der verschiedenen Anwendungsbereiche und Forschungserkenntnisse mündet die Dissertation in einer offenen Hard- und Software-Plattform für Earables namens "OpenEarable". OpenEarable umfasst eine Reihe fortschrittlicher Sensorfunktionen, die für verschiedene ohrbasierte Forschungsanwendungen geeignet sind, und ist gleichzeitig einfach herzustellen. Hierdurch werden die Einstiegshürden in die ohrbasierte Sensorforschung gesenkt und OpenEarable trägt somit dazu bei, das gesamte Potenzial von Earables auszuschöpfen. Darüber hinaus trägt die Dissertation grundlegenden Designrichtlinien und Referenzarchitekturen für Earables bei. Durch diese Forschung schließt die Dissertation die Lücke zwischen der Grundlagenforschung zu ohrbasierten Sensoren und deren praktischem Einsatz in realen Szenarien. Zusammenfassend liefert die Dissertation neue Nutzungsszenarien, Algorithmen, Hardware-Prototypen, statistische Auswertungen, empirische Studien und Designrichtlinien, um das Feld des Earable Computing voranzutreiben. Darüber hinaus erweitert diese Dissertation den traditionellen Anwendungsbereich von Kopfhörern, indem sie die auf Audio fokussierten Geräte zu einer Plattform erweitert, welche eine Vielzahl fortschrittlicher Sensorfähigkeiten bietet, um Eigenschaften, Prozesse und Aktivitäten zu erfassen. Diese Neuausrichtung ermöglicht es Earables sich als bedeutende Wearable Kategorie zu etablieren, und die Vision von Earables als eine vielseitige Sensorenplattform zur Erweiterung der menschlichen Fähigkeiten wird somit zunehmend realer
    corecore