36 research outputs found

    Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions

    Towards Highly-Integrated Stereovideoscopy for \u3ci\u3ein vivo\u3c/i\u3e Surgical Robots

    Get PDF
    When compared to traditional surgery, laparoscopic procedures result in better patient outcomes: shorter recovery, reduced post-operative pain, and less trauma to incisioned tissue. Unfortunately, laparoscopic procedures require specialized training for surgeons, as these minimally-invasive procedures provide an operating environment that has limited dexterity and limited vision. Advanced surgical robotics platforms can make minimally-invasive techniques safer and easier for the surgeon to complete successfully. The most common type of surgical robotics platforms -- the laparoscopic robots -- accomplish this with multi-degree-of-freedom manipulators that are capable of a diversified set of movements when compared to traditional laparoscopic instruments. Also, these laparoscopic robots allow for advanced kinematic translation techniques that allow the surgeon to focus on the surgical site, while the robot calculates the best possible joint positions to complete any surgical motion. An important component of these systems is the endoscopic system used to transmit a live view of the surgical environment to the surgeon. Coupled with 3D high-definition endoscopic cameras, the entirety of the platform, in effect, eliminates the peculiarities associated with laparoscopic procedures, which allows less-skilled surgeons to complete minimally-invasive surgical procedures quickly and accurately. A much newer approach to performing minimally-invasive surgery is the idea of using in-vivo surgical robots -- small robots that are inserted directly into the patient through a single, small incision; once inside, an in-vivo robot can perform surgery at arbitrary positions, with a much wider range of motion. While laparoscopic robots can harness traditional endoscopic video solutions, these in-vivo robots require a fundamentally different video solution that is as flexible as possible and free of bulky cables or fiber optics. This requires a miniaturized videoscopy system that incorporates an image sensor with a transceiver; because of severe size constraints, this system should be deeply embedded into the robotics platform. Here, early results are presented from the integration of a miniature stereoscopic camera into an in-vivo surgical robotics platform. A 26mm X 24mm stereo camera was designed and manufactured. The proposed device features USB connectivity and 1280 X 720 resolution at 30 fps. Resolution testing indicates the device performs much better than similarly-priced analog cameras. Suitability of the platform for 3D computer vision tasks -- including stereo reconstruction -- is examined. The platform was also tested in a living porcine model at the University of Nebraska Medical Center. Results from this experiment suggest that while the platform performs well in controlled, static environments, further work is required to obtain usable results in true surgeries. Concluding, several ideas for improvement are presented, along with a discussion of core challenges associated with the platform. Adviser: Lance C. PĂ©rez [Document = 28 Mb

    Vision Sensors and Edge Detection

    Get PDF
    Vision Sensors and Edge Detection book reflects a selection of recent developments within the area of vision sensors and edge detection. There are two sections in this book. The first section presents vision sensors with applications to panoramic vision sensors, wireless vision sensors, and automated vision sensor inspection, and the second one shows image processing techniques, such as, image measurements, image transformations, filtering, and parallel computing

    On-the-fly dense 3D surface reconstruction for geometry-aware augmented reality.

    Get PDF
    Augmented Reality (AR) is an emerging technology that makes seamless connections between virtual space and the real world by superimposing computer-generated information onto the real-world environment. AR can provide additional information in a more intuitive and natural way than any other information-delivery method that a human has ever in- vented. Camera tracking is the enabling technology for AR and has been well studied for the last few decades. Apart from the tracking problems, sensing and perception of the surrounding environment are also very important and challenging problems. Although there are existing hardware solutions such as Microsoft Kinect and HoloLens that can sense and build the environmental structure, they are either too bulky or too expensive for AR. In this thesis, the challenging real-time dense 3D surface reconstruction technologies are studied and reformulated for the reinvention of basic position-aware AR towards geometry-aware and the outlook of context- aware AR. We initially propose to reconstruct the dense environmental surface using the sparse point from Simultaneous Localisation and Map- ping (SLAM), but this approach is prone to fail in challenging Minimally Invasive Surgery (MIS) scenes such as the presence of deformation and surgical smoke. We subsequently adopt stereo vision with SLAM for more accurate and robust results. With the success of deep learning technology in recent years, we present learning based single image re- construction and achieve the state-of-the-art results. Moreover, we pro- posed context-aware AR, one step further from purely geometry-aware AR towards the high-level conceptual interaction modelling in complex AR environment for enhanced user experience. Finally, a learning-based smoke removal method is proposed to ensure an accurate and robust reconstruction under extreme conditions such as the presence of surgical smoke

    Augmented Reality Assistance for Surgical Interventions using Optical See-Through Head-Mounted Displays

    Get PDF
    Augmented Reality (AR) offers an interactive user experience via enhancing the real world environment with computer-generated visual cues and other perceptual information. It has been applied to different applications, e.g. manufacturing, entertainment and healthcare, through different AR media. An Optical See-Through Head-Mounted Display (OST-HMD) is a specialized hardware for AR, where the computer-generated graphics can be overlaid directly onto the user's normal vision via optical combiners. Using OST-HMD for surgical intervention has many potential perceptual advantages. As a novel concept, many technical and clinical challenges exist for OST-HMD-based AR to be clinically useful, which motivates the work presented in this thesis. From the technical aspects, we first investigate the display calibration of OST-HMD, which is an indispensable procedure to create accurate AR overlay. We propose various methods to reduce the user-related error, improve robustness of the calibration, and remodel the calibration as a 3D-3D registration problem. Secondly, we devise methods and develop hardware prototype to increase the user's visual acuity of both real and virtual content through OST-HMD, to aid them in tasks that require high visual acuity, e.g. dental procedures. Thirdly, we investigate the occlusion caused by the OST-HMD hardware, which limits the user's peripheral vision. We propose to use alternative indicators to remind the user of unattended environment motion. From the clinical perspective, we identified many clinical use cases where OST-HMD-based AR is potentially helpful, developed applications integrated with current clinical systems, and conducted proof-of-concept evaluations. We first present a "virtual monitor'' for image-guided surgery. It can replace real radiology monitors in the operating room with easier user control and more flexibility in positioning. We evaluated the "virtual monitor'' for simulated percutaneous spine procedures. Secondly, we developed ARssist, an application for the bedside assistant in robotic surgery. The assistant can see the robotic instruments and endoscope within the patient body with ARssist. We evaluated the efficiency, safety and ergonomics of the assistant during two typical tasks: instrument insertion and manipulation. The performance for inexperienced users is significantly improved with ARssist, and for experienced users, the system significantly enhanced their confidence level. Lastly, we developed ARAMIS, which utilizes real-time 3D reconstruction and visualization to aid the laparoscopic surgeon. It demonstrates the concept of "X-ray see-through'' surgery. Our preliminary evaluation validated the application via a peg transfer task, and also showed significant improvement in hand-eye coordination. Overall, we have demonstrated that OST-HMD based AR application provides ergonomic improvements, e.g. hand-eye coordination. In challenging situations or for novice users, the improvements in ergonomic factors lead to improvement in task performance. With continuous effort as a community, optical see-through augmented reality technology will be a useful interventional aid in the near future

    A gaze-contingent framework for perceptually-enabled applications in healthcare

    Get PDF
    Patient safety and quality of care remain the focus of the smart operating room of the future. Some of the most influential factors with a detrimental effect are related to suboptimal communication among the staff, poor flow of information, staff workload and fatigue, ergonomics and sterility in the operating room. While technological developments constantly transform the operating room layout and the interaction between surgical staff and machinery, a vast array of opportunities arise for the design of systems and approaches, that can enhance patient safety and improve workflow and efficiency. The aim of this research is to develop a real-time gaze-contingent framework towards a "smart" operating suite, that will enhance operator's ergonomics by allowing perceptually-enabled, touchless and natural interaction with the environment. The main feature of the proposed framework is the ability to acquire and utilise the plethora of information provided by the human visual system to allow touchless interaction with medical devices in the operating room. In this thesis, a gaze-guided robotic scrub nurse, a gaze-controlled robotised flexible endoscope and a gaze-guided assistive robotic system are proposed. Firstly, the gaze-guided robotic scrub nurse is presented; surgical teams performed a simulated surgical task with the assistance of a robot scrub nurse, which complements the human scrub nurse in delivery of surgical instruments, following gaze selection by the surgeon. Then, the gaze-controlled robotised flexible endoscope is introduced; experienced endoscopists and novice users performed a simulated examination of the upper gastrointestinal tract using predominately their natural gaze. Finally, a gaze-guided assistive robotic system is presented, which aims to facilitate activities of daily living. The results of this work provide valuable insights into the feasibility of integrating the developed gaze-contingent framework into clinical practice without significant workflow disruptions.Open Acces

    Medical Robotics

    Get PDF
    The first generation of surgical robots are already being installed in a number of operating rooms around the world. Robotics is being introduced to medicine because it allows for unprecedented control and precision of surgical instruments in minimally invasive procedures. So far, robots have been used to position an endoscope, perform gallbladder surgery and correct gastroesophogeal reflux and heartburn. The ultimate goal of the robotic surgery field is to design a robot that can be used to perform closed-chest, beating-heart surgery. The use of robotics in surgery will expand over the next decades without any doubt. Minimally Invasive Surgery (MIS) is a revolutionary approach in surgery. In MIS, the operation is performed with instruments and viewing equipment inserted into the body through small incisions created by the surgeon, in contrast to open surgery with large incisions. This minimizes surgical trauma and damage to healthy tissue, resulting in shorter patient recovery time. The aim of this book is to provide an overview of the state-of-art, to present new ideas, original results and practical experiences in this expanding area. Nevertheless, many chapters in the book concern advanced research on this growing area. The book provides critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies. This book is certainly a small sample of the research activity on Medical Robotics going on around the globe as you read it, but it surely covers a good deal of what has been done in the field recently, and as such it works as a valuable source for researchers interested in the involved subjects, whether they are currently “medical roboticists” or not
    corecore