40 research outputs found

    Reproducibility of Shin's method for necrotic core and calcium content in atherosclerotic coronary lesions treated with bioresorbable everolimus-eluting vascular scaffolds using volumetric intravascular ultrasound radiofrequency-based analysis

    Get PDF
    Although Virtual Histology intravascular ultrasound (VH-IVUS) is increasingly used in clinical research, the reproducibility of plaque composition remains unexplored in significant coronary artery and stented lesions. The purpose of this study was to assess the reproducibility of necrotic core and calcium content in atherosclerotic coronary lesions that were treated with a bioresorbable everolimus-eluting vascular scaffold (BVS) using a new measurement method (Shin's method) by VH-IVUS. Eight patients treated with a BVS (Abbott Vascular, Santa Clara, CA, USA) were analyzed with serial VH-IVUS assessments, i.e., pre- and post-stenting, and at 6 months and 2 years follow-up. A total of 32 coronary segments were imaged to evaluate the reproducibility of volumetric VH-IVUS measurements. In Shin's method, contours are drawn around the IVUS catheter (instead of the lumen) and vessel. Overall, in the imaged coronary segment, for necrotic core and dense calcium volumes, the relative intra-observer differences were 0.30 ± 0.22, 0.19 ± 0.16% for observer 1 and 0.45 ± 0.41, 0.36 ± 0.47% for observer 2, respectively. The interobserver relative differences of necrotic core and dense calcium volumes were 0.51 ± 0.79 and 0.56 ± 1.01%, respectively. The present study demonstrates a good reproducibility for both, intra-observer and interobserver measurements using Shin's method. This method is suitable for the measurement of necrotic core and dense calcium using VH-IVUS in longitudinal studies, especially studies on bioresorbable scaffolds, because the degradation process will be fully captured independently of the location of the struts and their greyscale appearance

    Assessment of the serial changes of vessel wall contents in atherosclerotic coronary lesion with bioresorbable everolimus-eluting vascular scaffolds using Shin's method: an IVUS study

    Get PDF
    Although serial changes in necrotic core and calcium are regarded as surrogates for the bioresorption process in patients treated with the bioresorbable everolimus-eluting vascular scaffolds (BVS), these temporal changes have not yet been fully investigated. Shin's method may be offer a more suitable technique for this analysis because it includes all the contents of both the lumen and vessel wall. The purpose of this study was to assess the serial changes of necrotic core and dense calcium content in coronary lesions that were treated with a BVS implant using Virtual Histology intravascular ultrasound (VH-IVUS) analyzed using Shin's method. A total of 29 patients (92 coronary segments) were imaged to evaluate the serial changes in necrotic core and dense calcium using Shin's method. Lesions treated with a BVS implant were analyzed with serial VH-IVUS assessments, i.e., pre- and post-stenting, and at 6 months and 2 years follow-up. In Shin's method contours are drawn around the IVUS catheter (instead of delineating the lumen) and the vessel. The mean necrotic core area decreased by 6.9% from post-stenting to 6 months (1.71 ± 1.03 mm2vs. 1.36 ± 0.91 mm2, P = 0.027), and by 20.5% (1.71 ± 1.03 mm2vs. 1.20 ± 0.70 mm2, P = 0.003) from post-steting to 2 years; while the mean dense calcium areas decreased by 27.2% (1.07 ± 0.55 mm2vs. 0.78 ± 0.64 mm2, P = 0.039) from post-stenting and 2 years. At 2 years, absolute necrotic core and dense calcium content were significantly decreased as compared to post-stenting values. The present study demonstrates that the bioresorption process in patients who undergoing BVS device implantation can be assessed using VH-IVUS analysed using Shin's method

    Morphological and functional evaluation of the bioresorption of the bioresorbable everolimus-eluting vascular scaffold using IVUS, echogenicity and vasomotion testing at two year follow-up: a patient level insight into the ABSORB A clinical trial

    Get PDF
    The aim of this study was to describe vaso-reactivity (by Acetylcholine and Methergine tests) at 2 year follow-up in parallel with the individual changes in the echogenicity characteristics of the polymer struts of the everolimus eluting bioresorbable vascular scaffold (BVS), from post-treatment to 2 year follow-up, in patients enrolled in the ABSORB Cohort A study. Intravascular ultrasound assessment was performed with a phased array catheter (EagleEye, Volcano Corporation, Cordova, CA, USA) with automated pullback at 0.5 mm per second. The % ratio at 6 months and 2 years [(Scaffold Area post PCI- Lumen Area)/Scaffold Area post PCI] was calculated as a measure of scaffold shrinkage. The % change of hyperechogenicity was defined as: ([post-procedural hyperechogenicity] - [2 year follow up hyperechogenicity])/[post-procedural hyperechogenicity]) × 100. The vasomotion test with intracoronary acetylcholine (10-6M) or intravenous methergine (0.4 mg) was performed at 2 years. Overall nine patients received all these analyses and were enrolled in the present analysis. A 50-96% reduction in hyperechogenicity was observed between baseline and 2 years, which corresponded to a change in vasoreactivity between 2 and 22%. A vasoconstriction of the scaffolded segment was observed in the 5 patients, who underwent the methergine test, with a mean decrease in lumen diameter after met

    Clinical outcomes after treatment of multiple lesions with zotarolimus-eluting versus sirolimus-eluting coronary stents (a SORT OUT III substudy)

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Data on clinical outcomes among patients treated with the zotarolimus-eluting Endeavor™ stent versus the sirolimus-eluting Cypher™ stent favor the sirolimus-eluting stent. However, a separate comparison of clinical outcome among patients treated for multiple lesions with these stents is lacking. We performed this comparison within the SORT OUT III trial data set.</p> <p>Methods</p> <p>Among 2332 patients randomized in SORT OUT III, 695 were treated for multiple lesions with zotarolimus-eluting (n = 350) or sirolimus-eluting (n = 345) stents and followed for 18 months. Major adverse cardiac events (MACE); composite of cardiac death, myocardial infarction, or target vessel revascularization (TVR); was the primary endpoint.</p> <p>Results</p> <p>Zotarolimus-eluting compared to sirolimus-eluting stent treatment was associated with increased MACE rate (13.2% vs. 2.6%; hazard ratio 5.29 with 95% confidence interval: 2.59-10.8). All secondary endpoints; all cause death, cardiac death, myocardial infarction, TVR, target lesion revascularization, in-stent restenosis, and definite stent thrombosis; were observed more frequently among zotarolimus-eluting stent treated patients. For all endpoints, hazard ratios were 1.6 to 4.6 times higher than in the overall results of the SORT OUT III trial.</p> <p>Conclusions</p> <p>We observed better clinical outcomes among patients treated for multiple lesions with the sirolimus-eluting stent compared to those treated with the zotarolimus-eluting stent.</p

    Genome-wide analyses identify a role for SLC17A4 and AADAT in thyroid hormone regulation.

    Get PDF
    Thyroid dysfunction is an important public health problem, which affects 10% of the general population and increases the risk of cardiovascular morbidity and mortality. Many aspects of thyroid hormone regulation have only partly been elucidated, including its transport, metabolism, and genetic determinants. Here we report a large meta-analysis of genome-wide association studies for thyroid function and dysfunction, testing 8 million genetic variants in up to 72,167 individuals. One-hundred-and-nine independent genetic variants are associated with these traits. A genetic risk score, calculated to assess their combined effects on clinical end points, shows significant associations with increased risk of both overt (Graves' disease) and subclinical thyroid disease, as well as clinical complications. By functional follow-up on selected signals, we identify a novel thyroid hormone transporter (SLC17A4) and a metabolizing enzyme (AADAT). Together, these results provide new knowledge about thyroid hormone physiology and disease, opening new possibilities for therapeutic targets

    Trans-ancestry meta-analyses identify rare and common variants associated with blood pressure and hypertension

    Get PDF
    High blood pressure is a major risk factor for cardiovascular disease and premature death. However, there is limited knowledge on specific causal genes and pathways. To better understand the genetics of blood pressure, we genotyped 242,296 rare, low-frequency and common genetic variants in up to ~192,000 individuals, and used ~155,063 samples for independent replication. We identified 31 novel blood pressure or hypertension associated genetic regions in the general population, including three rare missense variants in RBM47, COL21A1 and RRAS with larger effects (>1.5mmHg/allele) than common variants. Multiple rare, nonsense and missense variant associations were found in A2ML1 and a low-frequency nonsense variant in ENPEP was identified. Our data extend the spectrum of allelic variation underlying blood pressure traits and hypertension, provide new insights into the pathophysiology of hypertension and indicate new targets for clinical intervention

    The trans-ancestral genomic architecture of glycemic traits

    Get PDF
    Glycemic traits are used to diagnose and monitor type 2 diabetes and cardiometabolic health. To date, most genetic studies of glycemic traits have focused on individuals of European ancestry. Here we aggregated genome-wide association studies comprising up to 281,416 individuals without diabetes (30% non-European ancestry) for whom fasting glucose, 2-h glucose after an oral glucose challenge, glycated hemoglobin and fasting insulin data were available. Trans-ancestry and single-ancestry meta-analyses identified 242 loci (99 novel; P < 5 x 10(-8)), 80% of which had no significant evidence of between-ancestry heterogeneity. Analyses restricted to individuals of European ancestry with equivalent sample size would have led to 24 fewer new loci. Compared with single-ancestry analyses, equivalent-sized trans-ancestry fine-mapping reduced the number of estimated variants in 99% credible sets by a median of 37.5%. Genomic-feature, gene-expression and gene-set analyses revealed distinct biological signatures for each trait, highlighting different underlying biological pathways. Our results increase our understanding of diabetes pathophysiology by using trans-ancestry studies for improved power and resolution. A trans-ancestry meta-analysis of GWAS of glycemic traits in up to 281,416 individuals identifies 99 novel loci, of which one quarter was found due to the multi-ancestry approach, which also improves fine-mapping of credible variant sets.Peer reviewe

    Effect of remote ischaemic conditioning on clinical outcomes in patients with acute myocardial infarction (CONDI-2/ERIC-PPCI): a single-blind randomised controlled trial.

    Get PDF
    BACKGROUND: Remote ischaemic conditioning with transient ischaemia and reperfusion applied to the arm has been shown to reduce myocardial infarct size in patients with ST-elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI). We investigated whether remote ischaemic conditioning could reduce the incidence of cardiac death and hospitalisation for heart failure at 12 months. METHODS: We did an international investigator-initiated, prospective, single-blind, randomised controlled trial (CONDI-2/ERIC-PPCI) at 33 centres across the UK, Denmark, Spain, and Serbia. Patients (age >18 years) with suspected STEMI and who were eligible for PPCI were randomly allocated (1:1, stratified by centre with a permuted block method) to receive standard treatment (including a sham simulated remote ischaemic conditioning intervention at UK sites only) or remote ischaemic conditioning treatment (intermittent ischaemia and reperfusion applied to the arm through four cycles of 5-min inflation and 5-min deflation of an automated cuff device) before PPCI. Investigators responsible for data collection and outcome assessment were masked to treatment allocation. The primary combined endpoint was cardiac death or hospitalisation for heart failure at 12 months in the intention-to-treat population. This trial is registered with ClinicalTrials.gov (NCT02342522) and is completed. FINDINGS: Between Nov 6, 2013, and March 31, 2018, 5401 patients were randomly allocated to either the control group (n=2701) or the remote ischaemic conditioning group (n=2700). After exclusion of patients upon hospital arrival or loss to follow-up, 2569 patients in the control group and 2546 in the intervention group were included in the intention-to-treat analysis. At 12 months post-PPCI, the Kaplan-Meier-estimated frequencies of cardiac death or hospitalisation for heart failure (the primary endpoint) were 220 (8·6%) patients in the control group and 239 (9·4%) in the remote ischaemic conditioning group (hazard ratio 1·10 [95% CI 0·91-1·32], p=0·32 for intervention versus control). No important unexpected adverse events or side effects of remote ischaemic conditioning were observed. INTERPRETATION: Remote ischaemic conditioning does not improve clinical outcomes (cardiac death or hospitalisation for heart failure) at 12 months in patients with STEMI undergoing PPCI. FUNDING: British Heart Foundation, University College London Hospitals/University College London Biomedical Research Centre, Danish Innovation Foundation, Novo Nordisk Foundation, TrygFonden
    corecore